ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />METER <br />/o <br />200 amp <br />150 amp <br />UNDERGROUND IDIs <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER y <br />NEC 17. 250.94 <br />copper to lights & outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FPF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />R4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />\/ <br />WALL MOUNTED LIGHT FIXTURE <br />11 <br />11 <br />1 _- <br />ORECESSED <br />LIGHT FIXTURE <br />- <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />e <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />E----- <br />GF <br />O <br />EXHAUST FAN <br />GFI • db <br />,01 <br />EXHAUST FAN/LIGHT COMBINATION <br />DEDICATED RECEPTACLE <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />I'll"I <br />CHIMES (OPTIONAL) <br />l9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />fill <br />ELECTRIC PANEL <br />_i..j <br />DISCONNECT SWITCH <br />��19 <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />/ 1 I <br />I <br />SCA <br />MAIN FLOOR ELECTRICAL PLAN - ELEV-Al <br />SCALE: 14"=1'-0" <br />N <br />N <br />v <br />c� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and spedflcations contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seat is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature end seal. <br />Q <br />00 <br />o g 8 c <br />N " # <br />O <br />0 <br />N <br />(30 7 to o? N <br />tAr-- r—� <br />LJi <br />ik LL W <br />LL W a <br />0 <br />yM v <br />(a LL <br />L a. Y <br />a <br />O <br />00 <br />Wco <br />N rp <br />O13 <br />a <br />Z <br />ILa <br />M Z <br />NIL <br />y 0 <br />Z <br />OU <br />U <br />W <br />❑ ❑ ❑ <br />Z <br />z o <br />v <br />J <br />aU) <br />N <br />N <br />� C <br />C1 <br />�U <br />0 <br />W s <br />(n <br />v N <br />Ly N <br />W <br />$ <br />I <br />_. <br />C <br />M <br />J <br />O <br />7 <br />LL <br />E <br />=o <br />Q <br />Z <br />E <br />to <br />wgLq <br />� <br />C <br />�� <br />z�o <br />Z <br />Z <br />J <br />�z <br />Zo ° <br />W <br />Is <br />�( <br />J <br />cc <br />m <br />0 <br />L <br />� <br />� <br />N <br />� <br />0 <br />O <br />� <br />�� <br />30 <br />� <br />o <br />= <br />co <br />Lo <br />T <br />N <br />= cy) <br />o Q <br />,r <br />N <br />C) <br />M <br />o <br />Z <br />M <br />Z <br />E O <br />E <br />vi <br />JOB <br />NO: <br />21-5703 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />