Laserfiche WebLink
I■�I���� �NI�Ifi�W11�(LIw..Wa,I�J . w .-,1.:+,u. <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom <br />39" AFF <br />Laundry Room <br />36" AFF <br />Exterior Waterproof <br />12" AFF <br />Garage - general purpose <br />44" AFF <br />Range <br />2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation 8, <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/Carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />I ELECTRICAL KEY I <br />DUPLEX CONVENIENCE OUTLET <br />FRfF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />Lph <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />94 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />150A/200A INDOOR <br />PANEL CENTER <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />METER <br />nz/o <br />200 amp <br />150 amp ==r <br />UNDERGROUND Disconnect <br />POWER CO. FEED1 <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER �1 <br />NEC 17, 250.94 J <br />#14 copper to lights & outlets <br />a12 copper to 20 amp clas <br />I10-2 cropper to WH <br />#10-3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />�o TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® ELECTRIC DOOR OPERATOR (OPTIONAL) FC...._......, <br />CH CHIMES (OPTIONAL) SYSTEM <br />1-0 PUSH BUTTON SWITCH (OPTIONAL) <br />1-0 PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. $ (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />JICL ELECTRIC PANEL <br />—MM=L <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />�I <br />UPPER ELECTRICAL PLAN - ELEV-Al <br />SCALE:/4"=1'-0" <br />CV <br />0 <br />fV <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residentlal <br />7th Edition. Engineer's <br />signature and seal Is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />Q <br />(Oaf <br />O 8 <br />00 <br />tp n <br />N J <br />0 <br />LQV <br />B O C <br />� �' <br />J U. <br />LL w <br />d) <br />'C <br />to t- r­ <br />fy0 M ", <br />J u u- <br />LL w d <br />o- <br />SY� <br />a S <br />Z <br />L . C<n <br />ySO <br />0 ? <br />uj <br />f: <br />W <br />EEA 0 <br />T-a2d <br />X O <br />Z <br />IL LL <br />rR <br />N MZ <br />a 0 <br />ENO <br />Z <br />OUv�W <br />❑�❑ <br />W <br />Z � � <br />J <br />WLA <br />z <br />4- d <br />V � <br />0 <br />w g <br />�V) <br />N— <br />f__ <br />A <br />U)� <br />Of N <br />¢ & <br />�Q <br />C' <br />C:,W <br />co <br />ZM <br />u <br />E <br />E <br />w� <br />a =o <br />E u <br />r@ r6 <br />i a <br />R � � 0 <br />ZE <br />O <br />CV <br />i <br />r�� oQ <br />z <br />IF«O <br />rig <br />m� <br />�& <br />Z <br />O Z <br />N m Q W <br />y <br />�30 <br />W <br />fl- <br />T � <br />Z <br />NW <br />w a <br />s <br />Jp <br />v <br />Z5 $ <br />0 <br />> Cp <br />J <br />Crn <br />m <br />co <br />L <br />� <br />a <br />�> <br />30 <br />C) <br />a. <br />C:m <br />o <br />t\ <br />U') <br />/ <br />T f� <br />CCQ ' ^ <br />G Y J <br />N <br />= <br />CD <br />0 •-- <br />N <br />j C)t/1 <br />N <br />M o <br />Z <br />M <br />Z <br />E 10 <br />EE <br />C <br />a <br />U _j <br />¢ 0 <br />JOB <br />NO: <br />21-5703 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />