Laserfiche WebLink
(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />2x6 / 2x8 WALL BEYOND <br />(2) 2x HEADER TO SIT <br />FLUSH TO THE OUTSIDE <br />STANDARD 3" DIA. TEE <br />SEE PLAN FOR HEADER <br />SEE PLAN FOR SIZE <br />THREADED 3" DIA. EXTENSION <br />CONNECTION <br />SCREW OFF CAP (3" DIA.)—� <br />2x DEAD WOOD @ MID <br />FOR CLEAN -OUT <br />POINT w/ (3)12d <br />MIN. EXTENSION FROM <br />DOUBLE 2x TOP <br />S SPACED <br />EXTERIOR FACE OF BLOCK <br />EVONEAI <br />VENT OR 2ND FLOOR <br />TYPICAL C.M.U. WALL <br />3/4" FURRING STRIPS <br />1/2" GYPSUM BOARD <br />W/ DRYWALL SCREWS <br />@ 8" O.C. OR 4d <br />DRYWALL NAILS <br />PLATE WALL IS 1 1/2 MAXIMUM INTERIOR <br />HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR WALL <br />FACE OF BLOCK WALL IS 21/4" <br />J <br />2x BLOCKING @ EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />2x BOTTOM PLATE W/(1) 10d @ 8" <br />VARIES O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL 1 <br />SCALE: N.T.S. S4 <br />12 <br />SEE TYPICAL WALL SECTION <br />(�rp) SEE ELEV. <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2X4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />SIMPSON SP2 w/ (12)10d <br />(3)10d TOENAILS T&B <br />NAILS AT EACH STUD <br />AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />«'« STUD W/ (3)10d NAILS <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING —� <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 w/ (10)10d —� <br />NAILS AT EACH STUD <br />N 2x P.T. PLATE <br />,�. 5/8" x 10" "J" BOLT @ 24" O/C MAX � <br />W/8"EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />3 1 #5 VERT. IN CONC. FILLED CELL W/ <br />a STD. 90A HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />TO DRAIN CL <br />EXTERIOR <br />WALL CLEAN -OUT WALL <br />A <br />SCALE: N.T.S. S4 _ <br />7 5/8" 8" 7 5/8" 8" 7 5/8" 8" <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />12 <br />(TYP.) SEE ELEV. <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM C. <br />926 APPLY 3 LAYERS W/ TOTAL <br />THICKNESS 7/8" OVER METAL <br />LATH. FIRST 2 LAYERS 3/8" THICK <br />EACH. 3RD LAYER 1/8" THICK. <br />CRICKET AS REQUIRED <br />a FULL 8x8x16 BLOCK <br />SIMISON SP2 w/ (12)10d <br />NAI AT EACH STUD <br />I <br />—DOOR OPENING <br />DOOR OPENING —CL <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d <br />COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKIN <br />D <br />O/C FIELD <br />2X4 PT STUDS @ 16" O.C. <br />ID 1 <br />(2) 2X4 PT STUDS UNDER HIP <br />1ST COARSE 2ND COARSE 3RD COARSE <br />MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE <br />COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALL IS TO BE <br />WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />MASONRY LAYOUT rD <br />SCALE: N.T.S. �4� <br />CARRIER/GIRDER TRUSS <br />SIMPSON HETA20 w/ (8)10dx1 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEB <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />IN KO BLOCK AT EA. STUD <br />MOISTURE BARRIER <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED W/GROUT <br />REFER TO WINDOW PRODUCT APPROVAL <br />SHEETS FOR INSTALLATION INFORMATION BY <br />MANUFACTURER. <br />TYPICAL SECTION THRU WINDOW g <br />L MAIN SPAN <br />ROOF TRUSS <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />7 <br />CJ'4 <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT <br />■�����w <br />�A■MM <br />rul <br />b 11 00 <br />• • • <br />_ <br />... •- • <br />11 <br />=:Jill <br />1 <br />11 <br />MUM <br />III■.■ <br />■'lII <br />lid■'�■ <br />01111 <br />II <br />■III <br />I���i■ <br />WIIII__011 <br />IIII <br />Milli <br />MIIII <br />IIIIN <br />NOTES: <br />1Q FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />- - - PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />Q VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />BLOCKING (TYP.) PROPERLY. <br />\--ROOFTRUSS O3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />UPLIFT CONNECTOR (SEE SCHEDULE) ® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />CID <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />= <br />SEAT FOR BLOCK IS POURED, <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERALNOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />N <br />0 <br />R <br />SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />G <br />S4 <br />WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO <br />1/2"X9112" PLYWOOD CREATE A SOLID BASE FOR <br />BLOCK WALL ABOVE. <br />SCRAP MATERIAL <br />MOUNTING BASE SHOWN <br />IN POSITION <br />—2x6 MOUNTING BASE <br />J <br />T C) <br />FORM CREATES CONCRETE RECESS TO <br />2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />GARAGE ENTRY FORM DETAIL <br />�8x8xl6 C.M.U. GARAGE DOOR <br />GARAGE DOOR ROLLER _ <br />CONNECTION ASSEMBLY <br />GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />-TRACK MOUNTING BRACKET <br />\ \GARAGE DOOR TRACK <br />SCALE: N.T.S. <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B <br />BLOCK WALL. RECESSED SPACE TO BE 2"ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />sFFp oOh� <br />�N <br />2x CRIPPLES @ ---' <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1 /2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2x8 WALL) <br />10d NAILS @ 8" —� <br />O/C TYP. <br />DOUBLE 2x -- <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 900 HOOK IN K.O. BLOCK <br />VERTICAL JAM ALT. KNEEWALL ABOVE MASONRY WALL DETAIL <br />5!8'DIA. x J-BOLTS AT 6-3/4", 41-3/4 , 71 ,AND 96-3/8 ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. SCALE: N.T.S. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />2x6P. <br />J-BOLT <br />TRACK <br />BRACKET <br />W/MOUNTING ANGLE <br />(NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1'- 4' <br />1 <br />(2) <br />(1) <br />(2) <br />(1) LSTA30 <br />4'- 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA3071 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />-14 @ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />(2) 2x HEADER SEE PLAN <br />S4 INTERIOR HEADER: <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER • EXTERIOR HEADERS: <br />ONLY (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH <br />SIDE <br />' 2x STUDS TYP. <br />Op SIMPSON HTT4 TYP. <br />OHO �R U.N.O. SEE N/S4 <br />N(,� ** HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL rQ <br />SCALE: N.T.S. S4 <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />• SPLICE NAILS TOTAL) EA. SIDE OF <br />aE %9. SPLICE STAGGERED <br />ATTACH ALL J <br />EXTERIOR STUDS <br />W/ 4 16d TOENAILS <br />TO P PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL rM <br />SCALE: N.T.S. S4 <br />F= 2240 LBS <br />SIMPSON SIMPSON SIMPSON C <br />SP4 SP2 SIMPSON SP4 SP2 <br />2X STUDS @ 24" O.C. <br />!8"x10" "J" BOLT <br />@ 24" O.C. MAX. <br />IN. (2) PER <br />BOTTOM PLATE <br />SECTION 2X P.T. <br />PLATE <br />SIMPSON SP4 <br />101 <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />LINTEL <br />/ / - <br />°o a <br />SIMPSON <br />SP4 <br />a <br />INTO <br />TRANSOM <br />TRANSOM FRAMING <br />FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />SIMPSON <br />SPi <br />SIMPSON <br />SIMPSC <br />LNTELS <br />SP4 <br />SP4 <br />SIMPSON <br />SP2 -, <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />Spi SIMPSON <br />SIMPSON SP4 <br />SP4 <br />4IL I <br />BOTTOM CHORD OR 2x4 <br />[TRUSS <br />BLOCKING W/ 2-16d TOE NAILS <br />@ EACH END <br />Q <br />2x TOP PLATE <br />2-16d NAILS @ 24" O.C. OR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2x STUD @ 24" <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE EQUAL @ 12" O.C. <br />STAGGERED FROM BOT. <br />SEE A/S3 FOR <br />PLATE TO CONCRETE <br />REINF. INFO. <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL j <br />SCALE: N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />P.L. 1.8E Fb=2400 PSI (AS PER PLANS) <br />° a ° • HTT4 w/ (18)10d NAILS (3610# SPF) <br />° o • HTT5 w/ (26)10d NAILS (4670# SPF) <br />° ° • DTT2Z w/ (8)1/4" x 1 1/2" SDS (1835# SPF) <br />° o ° • HDU2-SDS2.5 w/ (6)1/4" x 21/2" SDS (2215# SPF) <br />° ° • HDU4-SDS2.5 w/ (10)1/4" x 21/2" SDS (3285# SPF) <br />_ • HDU5-SDS2.5 w/ (14)1/4" x 21/2" SDS (4065# SPF) <br />• HDU8-SDS2.5 w/ (20)1/4" x 21/2" SDS (5665# SPF) <br />• HDU11-SDS2.5 w/ (30)1/4" x 21/2" SDS (6865# SPF) <br />• 5/8" DIA. x 12" EPDXIED A.T.R. MIN. 8" <br />EMBEDMENT wl WASHER & NUT <br />0 • FOR DTT2Z USE 1/2" DIA. x 12" EPDXIED <br />A.T.R. MIN. 8" EMBEDMENT w/ WASHER & <br />NUT <br />• FOR HDU8 USE 7/8" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER & NUT <br />• FOR HDU11 USE 1" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER & NUT <br />HTT / HDU TENSION TIE rN <br />SCALE: NTS S4 <br />SIMPSON SP4 <br />�2X TOP PLATE <br />OVERLAPPING <br />�-10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />ROOF TRUSS ABOVE <br />%- 2X BLOCKING <br />o I 1 <br />2X8 P.T. BOTTOM P TE C <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. <br />C (MIN. (2) PER BOTTOM PLATE) <br />-(2) 16d TOE NAILS <br />EA. BLOCKING <br />'2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />SIMPSON C <br />SP4 <br />10d NAILS @ 4" A 10d NAILS @ 6" O.C. <br />STAGGERED STAGGERED <br />TRANSOM FRAMING <br />o o BEYOND. <br />PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES o E SHEATHING <br />& 8" O/C FIELD <br />S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE o PLYWOOD <br />SP8 FOR 2x8 WALL) o SHEATHING <br />• SIMPSON SP2 w/ (12)10d NAILS MASONRY <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />° <br />2X8 P.T. BOTTOM <br />D <br />PLATE <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />o PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY <br />SCALE: N.T.S. <br />Ili <br />0 °" <br />z$ <br />z <br />a <br />V) (D <br />Cz <br />4--J w <br />CQ o <br />•V <br />w <br />O = <br />~ <br />E <br />W <br />M <br />c N <br />M <br />'® ~ 8 <br />w <br />c <br />�00 <br />y <br />V <br />a;Qo <br />1 E <br />D. <br />.�//.� gn O <br />U Z W z <br />� H, <br />LU a g a w <br />W <br />10"'OAT <br />o <br />Z � in ID a o <br />UMZ tea, <br />W aI %,. I r. <br />\N Jr <br />'c. <br />VW <br />cr <br />•,.� F <br />• <br />'*ROFESy �I <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LE N NAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Z 4 <br />UF.00 <br />0VU <br />c <br />Nil; <br />8�. <br />o��R <br />O <br />N <br />ZZ <br />J Q <br />V <br />`J <br />J <br />t! <br />RE <br />0 <br />og8 <br />1 <br />I� <br />w <br />�°�J <br />r-I <br />u <br />w <br />Z <br />N <br />Z <br />J <br />`"I <br />L0 <br />�j <br />Q <br />� <br />� <br />z <br />C11 <br />Ln <br />k <br />m <br />r-1 <br />O <br />Cn <br />Z <br />Z <br />= <br />o <br />LU <br />O <br />.-•� <br />g <br />a <br />cn <br />LU <br />o <br />SCALE : AS NOTED <br />DATE : 10/4/2018 <br />TECH: JMUROSKI <br />VERSION N0. 4n0 <br />SHEET NO. <br />S4 <br />F <br />