Laserfiche WebLink
�o <br />N <br />LO <br />SEE STRUCTURAL NOTES AND <br />NAILING SCHEDULE FOR <br />SHEATHING DETAIL <br />TOP CHORD <br />BLOCKING FOR <br />FIRST FOUR <br />TOENAIL W/ (2)16d NAILS <br />2"x4" OUTLOOKER <br />@24"O.C. <br />BACKNAIL W/ (2)16d NAILS <br />SEE STRUCTURAL NOTES AND <br />NAILING SCHEDULE FOR <br />SHEATHING DETAIL <br />SIMPSON H10A w/ (18) BACKNAIL w/ (2)16d NAILS <br />10d x 1 12" AT EA. 2"x4" SEE STRUCTURAL NOTES - <br />OUTLOOKER OUTLOOKER AND NAILING SCHEDULE <br />1 @ 24" O.C. FOR SHEATHING DETAIL <br />ROWS OF <br />45° t <br />24" MAX. <br />TOP CORD BLOCKING 1 <br />45°t <br />2X4 CONT'L" BRACE <br />TRUSSES @ <br />SIMPSON H10A w/ (18) <br />FOR FIRST FOUR <br />FASTENED W/ (2)10d 3" <br />EDGES OF 2x4 CRO BRACE <br />10d x 1 12" @ EA. <br />ROWS OF TRUSSES @ <br />AT 24" O/C. CMID HEIGHT <br />SHEATHING APPROX. 8" FROM <br />OUTLOOKER <br />EDGES OF <br />TYPICAL @ RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />SHEATHING TYP. <br />2X4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />EXTEND AT LEAST 90% OF <br />48" O.C. EACH JOINT W/ (3) 10d <br />MAX. & (2)10d TOE NAILS @ <br />AT LEAST 90% OF WEB <br />2x4 CROSS BRACE <br />@ 8'-0" O/C. <br />WEB LENGTH & NOTCH AT <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />2x6 P.T. <br />GABLE TRUSS <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />SILL <br />1/2" CDX PLYWOOD OR <br />EACH JOINT W/ (2) 10d <br />FROM LEDGER TO <br />7/16" OSB SHEATHING <br />& (2)10d TOE NAILS @ <br />EA. END <br />BLOCKING <br />— -� <br />ATTACHED W/ 10d <br />NAILS @ 6" O.C. EDGES <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />AND 12" O.C. FIELD <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />10dX3" @ 3" O/C <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />1/2" CDX PLYWOOD OR 7/16" <br />THROUGH CHORD <br />CORD ATTACHED W/ (2)16d TOENAILS <br />OSB SHEATHING ATTACHED <br />10d NAILS 6" O.C. <br />INTO 2"x6" P.T. PLATE <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />w/ @ <br />EDGES AND 12" O.C. FIELD <br />2x4 "T' ON TOP OF PANEL BLOCKING, <br />WEEP SCREED <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />FASTEN WITH 10dx3" @ 4" O/C SPACED <br />INSTALLED PER MANUF. <br />2"x6" P.T. SILL <br />NOTCH "L" BRACE HERE <br />@ 48" O.C. <br />MOISTURE BARRIER <br />5/8" x 10" "J" BOLT @ 48" O.C. <br />I; <br />WEEP SCREED <br />5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM <br />SIMPSON HETA20 w/ (8)10dxl 1/2" NAILS AT 6'-0" <br />INSTALLED PER MANUF. <br />PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER <br />SIMPSON HETA20 w/ (8) <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />10dx1 1/2" NAILS AT EA. <br />ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS <br />NOTE: IF EMBEDDED <br />TRUSS VERTICAL WEB (24" <br />& (4) 1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL <br />SECTION <br />O.C. MAX) w/ MIN. 4" <br />1 EMBEDMENT IN KO BLOCK <br />GABLE WEB <br />SECTION <br />2 <br />WEB, USE MSTAM36 w/ (7) <br />10d NAILS & (4)1/4"x21/4" <br />SCALE: N.T.S. <br />S5 <br />SCALE: N.T.S. <br />S5 <br />TITEN ON OUTSIDE <br />BACKNAIL W/ (2)16d NAILS <br />REFER TO DETAIL J SEE STRUCTURAL <br />ON SHEET S5 FOR M NOTES AND NAILING <br />X-BRACING, AND TOP <br />CHORD BLOCKING N SCHEDULE FOR <br />INFORMATION `o 00 SHEATHING DETAIL <br />1 1 1f ". 2"x4" CROSS BRACE <br />WOOD TRUSSES APPROX. 8" FROM <br />RIDGE FASTENED AT <br />2x4 RAT RUN BRACING " EACH JOINT W/ (2) It <br />AT 24" O.C. ON TOP OF 1 1 2^ 1 1 2" 10d & (2)10d TOE <br />BOTT. CHORD FOR 4 NAILS @ EA. END <br />TRUSS SPANS <br />ATTACHED W/ 2 -16d 2x4 PANEL BLOCKING <br />AT EA. TRUSS JOINT „ " " ( (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF @ 48" 0/C FOR THE <br />(2) 2 x 4 LAMINATIONS W/ (1) ROW (3) 2 x 4 LAMINATIONS W/ 1) ROW FIRST (4) ROWS OF lo <br />a <br />F1 <br />Fi <br />2x4 BLOCKING 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS TRUSSES FROM EA. <br />@ (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL END TYP. TOP & <br />O/C w/(2)16d <br />TOENAILS @ EA. END NOTES: BOTTOM ATTACHED <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4"DIA. x 51/2" LAG SCREWS OR EQUAL w/ (2)16d TOENAILS <br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) <br />SIMPSON H10A w/ (18) SIMPSON SP4 w/ (6)10d x <br />10d x 1 12" AT EA.7 1 12" AT EA STUD (USE BACKNAIL w/ (2)16d NAILS <br />OUTLOOKER SP6 FOR 2x6 WALL, USE <br />SP8 FOR 2x8 WALL) SEE STRUCTURAL NOTES - <br />AND NAILING SCHEDULE <br />FOR SHEATHING DETAIL <br />2x4 OUTLOOKER @ 24" <br />O.C. (OPTIONAL - SEE <br />TOP CORD BLOCKING <br />FOR FIRST FOUR ROWS <br />4" Mom'DOUELEVATIONS) <br />OF TRUSSES @ EDGES <br />OF SHEATHING TYPICAL <br />BLE TOP PLATE <br />2"x4" CROSS BRACE <br />2x4 CROSS BRACE APPROX. 8" <br />APPROX. 8" FROM <br />FROM RIDGE FASTENED AT <br />RIDGE FASTENED AT <br />EACH JOINT W/ (2)10d & (2)10d <br />EACH JOINT W/ (2) <br />TOE NAILS @ EA. END <br />10d & (2)10d TOE <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />: <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />AND 12" O.C. FIELD <br />NAILS <br />END TYP. TOP & <br />BOTTOM ATTACHED <br />DQI(2)16d <br />2x4 PANEL BLOCKING @ 48"A <br />2x BLOCKING <br />W/ (2)16d TOENAILS <br />O.C. FOR THE FIRST (4) <br />ROWS OF TRUSSES FROM <br />2 4'7" ON TOP OF PANEL <br />SIMPSON H10A w/ (18) <br />10d x 1 12" AT EA. <br />OUTLOOKER <br />(2)16d <br />2x4 OUTLOOKER <br />@ 24" O/C <br />TOP CORD <br />BLOCKING FOR <br />FIRST FOUR ROWS <br />OF TRUSSES @ <br />"MAX, EDGES OF <br />SHEATHING TYP. <br />-1" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />r-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR <br />7/16" OSB SHEATHING <br />ATTACHED w/ 10d NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />-2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />10dx3" @ 4" O/C <br />EA. END TYP. TOP & BLOCKING, FASTEN WITH SIMPSON HGAIOKT w/ (4)1/4"x1 1/2" <br />BOTTOM ATTACHED w/ (2) 10dx3" @ 4" O/C SDS SCREWS TO TRUSS & (4)1/4"x3" SIMPSON SP2 w/ 12 <br />16d TOENAILS SDS SCREWS TO PLATES AT 36 O.C. ( )10d <br />2x4 LEDGER (MATCH BOTTOM DBL. TOP PLATE NAILS AT EACH STUD <br />CHORD SLOPE OF ADJACENT TRUSS) STUD WALL SEE TYP. SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />SIMPSON H10A w/ (18) <br />10d x 1 12" AT EA. 2x4 OUTLOOKER <br />OUTLOOKER @ 24" O/C <br />TOP CORD <br />BLOCKING FOR <br />FIRST FOUR ROWS <br />OF TRUSSES @ <br />24" MAX. EDGES OF <br />SHEATHING TYP. <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />GABLE TRUSS <br />1/2" CDX PLYWOOD OR 7/16" <br />(2)16d NAILS OSB SHEATHING ATTACHED <br />W/ 10d NAILS @ 6" O.C. <br />E ES AND 12" O.C. FIELD <br />r� <br />JACK TRUSS <br />_SEE PLAN FOR <br />- / <br />e"-_ ,CONNECTION <br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL 2x4 "T" ON TOP OF PANEL- I i L <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) BLOCKING, FASTEN WITH I- 2x4 BLOCKING W/ :. <br />10dx3" @ 4" O/C (2)12d TOENAILS -L <br />EXT. WALL CONN. 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATIONa <br />COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />NON - LOAD BEARING LOCATION D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION g <br />SEE TYP. WALL SECTION FOR SCALE: 3/4"= V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 <br />ADDITIONAL INFORMATION. <br />SIMPSON HGAM11 <br />W/ <br />(4)1/4"x1 1/2" SDS <br />SCREWS <br />TO BLOCKING & ( <br />1 /4 x2 3/4 <br />TITEN TO CMU <br />0 <br />I <br />MINIMUM 2x <br />Q CROSS BRACING <br />(SEE PLAN OR <br />LOCATIONS) <br />(2)16d PER <br />E IN JOINT <br />3 CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 <br />CROSS BRACING DETAIL ri <br />z SCALE: N.T.S. S5 <br />N <br />2"x4" OUTLOOKER @ 24" - <br />O.C. W/ (2)10d PER JOINT <br />10dx3" O/C @-/2"x4 <br />TOENAIL 6" O/C RUNN <br />W/ (2)16d TYPICAL <br />NAILS >,.. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL <br />SCALE: N.T.S. <br />1 GABLE TRUSS <br />"L" BRACE W/ 10d @ 4" O.C. <br />rn 12 (SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />6.9 MAX. <br />SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />S5 SCALE: N.T.S. S5 <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />`- MINIMUM (2)16d PER JOINT \- MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S. <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C 2 x 4 BLOCKING w/ (2)10d <br />WOOD TRUSSES rTOE NAILS AT EACH END @ <br />l 24" O/C (TYP) <br />`BRACING w/ (3)10d x 3" AT <br />• <br />EACH CONN. @ 24" O/C <br />SIMPSON HGAM10KTA w/ (4) <br />MOISTURE BARRIER <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4) 1/4"x2 3/4" <br />BOND BEAM <br />TITEN TO CMU <br />MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. NON - LOAD <br />BEARING LOCATIO (UNEVEN CLG.) rE <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5 <br />ADDITIONAL INFORMATION. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />010" - 3'-0" <br />T-0" - 6'-0" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />S5 � <br />rSCR SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS <br />g / TO PLATES (TYP.) <br />CONT, BEARING <br />GABLE END BRACING DETAIL <br />` MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SCALE: N.T.S. <br />`GONT. BEARING <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />HIP FRAMING REFERENCE PLAN <br />2x4 BLOCKING 2x4'7" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4'T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" O/C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE -� <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 1 CONTINUOUS BOTTW CHORD BRACING 2X4 MIN. <br />Ll <br />1111 <br />111 <br />NOTE: <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />THAT MY BE REQUIRED <br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI 1-13 <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />ZTOP & BOTTOM CHORD <br />GABLE END BRACING @ <br />4'-0" O.C. MAX. FOR <br />FIRST (4) ROWS OF TRUSSES <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />\ 11 <br />n <br />o v <br />zCn <br />z�z <br />U, z <br />LU <br />p <br />•U <br />ry <br />0 c <br />U <br />� <br />LU <br />\ ® ~ <br />Q1 P! <br />-f M <br />N <br />U <br />�cc <br />�o <br />I N N <br />Z fsk zd <br />CA <br />11'.. <br />ii j LL t� Uj I�x. <br />W f!) g a <br />a <br />Z <br />42. <br />LL <br />jW'N'Q <br />.' <br />v •�• ay <br />•� <br />U' •.J� �� <br />p� Q <br />,. .o X� 4 <br />'°•'•.. •••••fir <br />r0 F E SS <br />F�"'rifillllitllE�t�l <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering potions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />W <br />& <br />�z 0 <br />�' <br />> <br />J <br />z <br />z <br />DC <br />c <br />N <br />Q <br />a <br />Q <br />LU <br />O <br />u <br />0 <br />;o zn <br />=1w <br />98 <br />LZ <br />z <br />J <br />Ln <br />8. <br />r-1Lii <br />LLI <br />z <br />ra <br />l— <br />Ln <br />p <br />z <br />z <br />g <br />tj <br />= <br />8 <br />0 <br />.__4 <br />a <br />cn <br />s <br />SCALE : AS NOTED <br />DATE : 10/4/2018 <br />TECH: JMUROSKI <br />VERSION NO. 4n0 <br />SHEET NO. <br />S5 <br />