My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3327 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3327 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:39:10 PM
Creation date
2/19/2025 10:34:34 AM
Metadata
Fields
Template:
Building Plans
Street #
3327
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
2349
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A <br />INDOOR <br />PANELCENTER <br />10 #14 copper to lights & outlets <br />150 10 #12 copper to 20 amp ckts <br />NMP/ 1 <br />AAM <br />200 AMP 01 #10-2 copper to WH <br />10 #10-3 copper to Dryer <br />!R -T <br />MAIN <br />or 4/0 SER Alu <br />Y210 <br />200amp <br />150amp <br />UNDERGROUND <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />Y WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be. 16 AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />FE9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />T�2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />�J]M ELECTRIC METER .,.,, 1. —I <br />BUILDER <br />Mill ELECTRIC PANEL <br />WP GFI DISC. <br />H.B. <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn ono 0173EY10 <br />SCALE: NTS <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />GID <br />(1) PHONE LINE, (1) DATA PORT <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=1'-0" <br />N <br />0 <br />CV <br />v <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building <br />Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />0 <br />W <br />I- <br />v E <br />O a 8 <br />r <br />co <br />N <br />N N m <br /># LL <br />,+ <br />V <br />C <br />N O C <br />aO o) <br />� J , <br />Xk '� W <br />H <br />0 QJ <br />0 <br />v) r- r-� <br />cc)i v <br />LL LL <br />W CL <br />LL a Y <br />a L <br />O <br />Z/ <br />0 <br />CO <br />L 0 J <br />W <br />0 rrnQ¢Q <br />Z <br />u <br />to c'oo <br />a <br />0:tn 0 <br />Z <br />O U <br />v <br />M <br />SRI <br />Z N M <br />O <br /><c <br />J <br />r` <br />N <br />� <br />o <br />J <br />a- <br />0Lug <br />�Un <br />Ln <br />N <br />N <br />~We <br />� <br />r-- W <br />tJ <br />fer J <br />F— _ <br />c� <br />a; <br />U o Z6 <br />o <br />N o <br />I� <br />o <br />w <br />M <br />M <br />i <br />o <br />z <br />¢ <br />14O <br />J <br />LL <br />Q E <br />z o <br />o� <br />z <br />z ry <br />¢o <br />? OO <br />oa <br />(6 <br />to <br />_ C <br />o <br />XU <br />u o <br />�U <br />O <br />U 2 <br />Z <br />O <br />N <br />N <br />F <br />d o <br />¢ o <br />o <br />¢o <br />az <br />W <br />i <br />00 <br />C/D CY <br />m� <br />a <br />°zLL <br />Z <br />N J <br />�m <br />u, <br />d <br />Q <br />o< <br />z Z <br />do <br />z 3 <br />�w <br />wo <br />¢o <br />r� <br />>O <br />o <br />O <br />w� <br />za3 <br />a <br />°r <br />0 <br />C O <br />i <br />> L6 <br />Q <br />m <br />rn <br />to <br />O <br />L <br />jCN <br />/� <br />\` <br />LL Y <br />0 <br />0 <br />Q <br />0 <br />m <br />p <br />W <br />O <br />d. <br />T- <br />-O O <br />r <br />= N <br />75 o <br />ui <br />E <br />Itt <br />o <br />Z <br />to <br />Z <br />� <br />E (D <br />,; <br />`m <br />c <br />11. <br />U -j <br />Q 0 <br />-j <br />JOB <br />NO: <br />21-5701 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />