My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3327 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3327 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:39:10 PM
Creation date
2/19/2025 10:34:34 AM
Metadata
Fields
Template:
Building Plans
Street #
3327
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
2349
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />o I <br />ro <br />i <br />I <br />I ZONE-1 <br />I <br />3'-0" <br />ATTIC SPACE <br />o <br />� I <br />5:12 SLOP <br />2377 SQ. FT. <br />I <br />r <br />I <br />o <br />uj <br />J <br />o <br />Li <br />5:12 SLOPE, r <br />I <br />RIDGE <br />7'-0' RIDGE VENT r <br />z <br />�— <br />W <br />Ill <br />0 <br />Q _j <br />�� �9� <br />0 <br />:12SLOPE O <br />� <br />14'-0' RIDGE VENT <br />z <br />RIDGE <br />r-----------� <br />LU <br />LL <br />0 <br />I <br />I <br />I <br />I <br />5:12 SLOPE <br />Ia <br />w <br />r <br />I <br />I <br />I <br />I <br />ti,A <br />I <br />I <br />I <br />I <br />I <br />- ------------------------------------------------------ <br />0 <br />I <br />I <br />I <br />I <br />ROOF PLAN - ELEV-Bl_ <br />SCALE: %4"=1'-0" <br />ATTIC <br />VENTILATION <br />CALCULATIONS <br />- B1 (TRB) <br />Attic Ventilation <br />ATTIC VENTILATION <br />REQUIRED <br />UPPER VENTILATION <br />PROVIDED <br />Attic Ventilation to be in compliance with the Florida Building Code 7th Edition <br />(2020) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />but no more than 50°I° of the required ventilation is provided in the upper portion of <br />Req.) <br />(Ft.) <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />Total <br />(measured vertically) below the ridge or highest point of the space, with the <br />Ventilation <br />balance of the required ventilation provided by cave or cornice vents. <br />ATTIC <br />SQ. FT. <br />SQ. IN. of <br />Provided <br />by Upper <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />SPACE <br />SQ. IN. of SQ. FT. <br />Total SO. <br />of <br />ventilation to <br />Ventilators <br />(Values to be verified with Manufacturer Specifications) <br />of vented <br />IN. of <br />SQ. IN. of <br />SQ. IN. of <br />•OFF -RIDGE VENTS - 138 SO. IN. OF NET FREE AREA /UNIT <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />See Elev <br />( ) <br />SOFFIT VENTS - 7 SO. IN. OF NET FREE AREA / SO. FT. <br />required needed <br />required <br />soffit <br />by upper <br />•STUCCO SOFFIT VENTS - 126 SO. IN. OF NET FREE AREA / SO. FT. <br />needed <br />ventilators <br />'If not enough vented soffit is provided due to fire protection, the contractor shall use the <br />following approved vents: <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 S0. IN. OF NET FREE AREA / FT. <br />**Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />Main <br />21 <br />2 <br />Floor <br />2377 <br />2282 <br />326 <br />1141 <br />81 <br />570 <br />591.0 <br />315.0 <br />276.0 <br />(Zone 1) <br />'*NOTE*' <br />GENERAL <br />CONTRACTOR <br />MUST ENSURE THAT <br />PROPER VENTILATION IS PROVIDED <br />AT EAVES/SOFFITS <br />AS <br />REQUIRED <br />BY FLORIDA <br />BUILDING CODE 7TH <br />EDITION (2020) RESIDENTIAL.OT <br />RM <br />c <br />0 <br />•5 <br />J <br />LZ <br />i <br />aw <br />E1ft4l� 1 �. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering po <br />
The URL can be used to link to this page
Your browser does not support the video tag.