My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3083 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3083 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:32:56 PM
Creation date
2/19/2025 10:42:59 AM
Metadata
Fields
Template:
Building Plans
Street #
3083
Location
Kresterbrooke Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
19698
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTIC VENTILATION CALCULATIONS - Al General Notes <br />ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED ROOF CRITERIA: <br />1 0 12" OVERHANG U.N.O. <br />1/150 Rule 1/300 Rule Ridae Off -Ridge 0 PLUMB CUT FASCIA ROOF <br />(No Upper Ventilators (Must Provide Upper Ventilators) Vent �mt Amt. 0 PITCH PER ELEVATION <br />Req.) (Ft.) Total **G.C. VERIFY ROOF PITCH" <br />Ventilation ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />ATTIC Provided CONTRACTORS RESPONSIBILITY TO VERIFY <br />SPACE SQ. FT� Total SQ. SQ. FT. SQ. IN. of by Upper <br />SQ. IN. of of vented IN. of of ventilation to SQ. IN. of SQ. IN of Ventilators ROOF SLOPE REQUIREMENTS WITH TRUSS <br />ventilation soffit ventilation vented be provided Ventilation Ventilation (See Elev) MANUFACTURER. <br />required needed required soffit by upper <br />needed ventilators "ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />Main 4.000000 2.000000 TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />Floor 1080 1037 148 518 37 259 336.0 <br />(Zone 1) 60.0 276.0 LOCATION PURPOSES. <br />Main 0.0 0.000000 Exterior Covering <br />Floor 16 15 2 8 1 4 0.0 R703.7 Exterior plaster. <br />(Zone 2) 0.0 - 0.0 Installation of these materials shall be in compliance with ASTM C <br />Upper 16.000000 0.000000 926 and ASTM C 1063. <br />Floor 1166 1 11�1 160 560 40 280 240.0 <br />(Zone 3) 240.0 0.0 R703.7.1 Lath. <br />— All Lath and lath attachments shall be of corrosion -resistant <br />6" "NOTE- materials. Attached per ASTM C 1063. <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. R703.7.2 Plaster. <br />Plastering w/ portiand cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />....................... ............... ............................................ .................. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />-based sheathing, shall include <br />(stucco) is to be applied over wood <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />RD <br />2. One layer of an approved water -resistive barrier (paperbacked <br />0. stucco lath) over an approved synthetic house wrap. <br />0 <br />_J <br />t A co R703.4 Flashing. <br />C14 Approved corrosion -resistant flashing shall be applied <br />to. shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />Exterior window/door openings. <br />0 <br />0 Intersection of chimneys or other masonry contructions with <br />ulk frame walls. <br />, ................................... 0 <br />0- ... ..................................... 2 Under and at the ends of masonry, wood or metal copings <br />0 <br />and sills. <br />Continuously above all projecting wood trim. <br />N RIDGE ..... Where exterior porches, decks or stairs attach to a wall or <br />LO floor assembly of wood -frame construction. <br />12'-O'RIDGE VENT <br />0 At wall and roof intersections <br />0 At Built-in gutters. <br />1&0 <br />Attic Ventilation <br />:3 <br />4'-O'ROOF VENT Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />z (2017) Residential R806. <br />Lu The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />FAI[OM . ..... <br />jfi� space. The ventilating area may be reduced to 11300 provided that at least 40% <br />TJ:12 SLOPE 0 <br />4'-O'RIDGE VENT a Fr but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventlated.Upper venfilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or comice, vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />W-O' R, (Values to be verified with Manufacturer Specifications) <br />RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />a OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />a SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />... 5:12 SL04 <br />Ir -7 a O'HAGIN WEATHERMASTER (Shingle Roo� - 72 SQ. IN. OF NET FREE AREA/ FT. <br />** (Sq. Ft. Soffit Needed) x 7 - (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />a LOMANCO DECK -AIR (Shingle Roofi - 9 SQ. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft Soffit Needed) x 7 m (Sq. In. Needed) / 9 - (Linear Ft. of Deck -Air Needed) <br />a O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT <br />"Formula: (Sq. Ft. Soffit Needed) x 7 - (Sq. In. Needed) f 86.25 - Amount of O'Hagin Vents Needed <br />Lu L. _J <br />0. . . . . . . . . . . . <br />0 <br />.................. : : ......................... <br />........... ..... <br />C14 <br />W <br />a. <br />0 . . . <br />04 <br />. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . .. <br />. ... . . . . . . . . a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />ROOF PLAN <br />SCALE: Y4"=1'-0'1 <br />I <br />V) (D <br />a) C—/) <br />LU <br />U 121% <br />L.L.1 F- <br />0 E <br />ca <br />LU <br />0 <br />= LL <br />LO <br />0 <br />N C-B D. % <br />Al I I \41__ <br />IV <br />RID.1 <br />Z_- Q� <br />0) <br />el, <br />z o' <br />LLM A R.. - <br />0 cj <br />Z, <br />TKI <br />z <br />00 <br />To the best of the Engineer's knowledge, Information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signatu re and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />C:) <br />Z r*4 <br />0 (L) N <br />1-� ;kJ C) <br />V) :3 ko <br />> J.) rn Q <br />M CD <br />M Ln <br />< <br />CL <br />(v 0 Ln <br />< L- M <br />F- efy-)` <br />CL 00 <br />< <br />z z E <br />z M <br />WLij C) F- <br />_J C:) <br />z <br />Z LO, 0 <br />UJ <br />Ch <br />00 <br />00 <br />r%1.J z <br />R <br />z <br />Lr) <br />0 <br />U <br />fu CL 99 . <br />U_ r- R 6 <br />0 Jgg <br />0 <br />f-4 cr_ <br />uJ oc <br />< a <br />ce <br />z 2 <br />z <br />LLJ Ln d;g <br />_J -4 Lij ICE 08 <br />< <br />fn z <br />C) Z t- <br />r-J Z U <br />z <br />M ob :5 UJ �@ <br />z <br />0 Lu <br />rn V__I 0- 1 Ul) �21.: <br />SCALE AS NOTED <br />DATE 1/4/2018 <br />TECH: ERAND <br />VERSION No' 10 <br />SHEET NO. <br />5.0 <br />