ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />r% <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39"AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included In the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I ELECTRICAL KEY I <br />�& <br />DUPLEX CONVENIENCE OUTLET <br />Lz±s-. <br />PEPP <br />DUPLEX OUTLET ABOVE COUNTER <br />1 Z7�1 <br />F�`W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />�&G.F.l. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />I Zn, <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />):�LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />F51 CHIMES (OPTIONAL) <br />0 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />Millen <br />ELECTRIC PANEL <br />—Elk--i <br />DISCONNECT SWITCH <br />11c", <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br /><1/ \> <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />< <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14,250.94 <br />200A INDOOR PANEL <br />CENTER <br />10 # 14 copper to lights & outlets <br />NEMA 1 01 #12 copper to 20 amp ckta <br />200 AMP <br />10 #10-2 copper to WH <br />01 #10-3 copper to Dryer <br />METER <br />MAJIN T <br />0 Y-2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />UPPER FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=V-0" <br />0 t9m <br />U <br />V) IUD <br />(Dra <br />M <br />U — <br />0 Lij <br />Lh <br />n-2 <br />E <br />02 <br />U <br />10) � <br />0) <br />Li - 8 2 <br />0 .1 04 <br />C) <br />LL <br />U H <br />< CM <br />C; <br />A I <br />N <br />*I <br />/r <br />u_ 'u;- <br />Uj <br />LU 0- LU <br />Us <br />001. <br />Z <br />-11-46 cil <br />Z <br />LL3 <br />d) <br />00 <br />To the best ofthe Ens ear's knowledge, Information, and <br />belief, the structural a s and specifications contained <br />2. <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signatu re and seal Is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />C) <br />Z <br />0 cu <br />1­4 C) <br />Lf) t,0 <br />C:) <br />Z <br />> <br />—4 C) <br />U-) M Ln <br />'Y'L <br />'a <br />V) 0 N <br />0) — V) <br />< L_ LL <br />Z <br />F- <br />U <br />W CL 00 <br />< <br />Z E <br />Z <br />Lu <br />W <br />_j 0 <br />`1.0 <br />Z g <br />am-, <br />Z80 <br />W () <br />08 W <br />_j <br />< <br />Mx_j <br />ME <br />00 <br />OC) <br />F- <br />8 <br />Z <br />U_j <br />Z <br />C: <br />Ln <br />j <br />LU <br />0 <br />a <br />0 <br />U <br />0 <br />_j <br />LL_ <br /><,n <br />uj 0 <br />< <br />'oe <br />0 uj ce <br />Z <br />Z <br />LLJ <br />Lr) <br />_j <br />< 65 0 <br />Z <br />Z <br />0 <br />C'4 <br />06 <br />Z <br />rn <br />T-q <br />0. <br />Ul <br />X <br />SCALE AS NOTED <br />DATE 1/4/2018 <br />TECH: ERAND <br />VERSION NO' 10 <br />SHEET NO. <br />4.1 <br />