ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44"AFF <br />bathroom 39" AFF <br />laundry room 36"AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance With the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC: R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an AtC electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFC1 protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I ELECTRICAL KEY I <br />DUPLEX CONVENIENCE OUTLET <br />F� <br />DUPLEX OUTLET ABOVE COUNTER <br />1. Z!�, <br />PE5W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I Ph <br />FW <br />SPECIAL PURPOSE OUTLET <br />:G <br />DUPLEX OUTLET IN FLOOR <br />I zns <br />P��E <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />d% . <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />):�LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />K <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />Iwo EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />rC H] CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />noij <br />DISCONNECT SWITCH <br />f,Q% <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />\> <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br /></ <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA 1 <br />200 AMP #12 copper to 20 amp clas <br />#10,2 copper to WH <br />910-3 copperto Dryer <br />MAIN <br />0 <br />or 410 SER Alu <br />200 amp <br />150 amp <br />=V210 <br />POWER CO. FEED— <br />DI§onnWI <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />C —1114 <br />GROUNDING WIRE <br />TERMINATION PERJ <br />F— <br />WITH CODE APPROVED <br />NEC 14,250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />ENTRY <br />VESM17 T Wim 1 r—r% <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4`"=1'-0" <br />U') <br />CX_ <br />V) (D <br />LU <br />0 U, <br />r� <br />Z:) <br />E <br />, <br />LU <br />M <br />< <br />A I <br />x c R 0 c <br />S Q_ UJI <br />U,< 0- <br />zo---� <br />LZ <br />L U1 <br />C.) C-> I— <br />EI 0 <br />To the best of the Engineer's knowledge, Information, and <br />belief, the structure I plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature, and <br />portions of :eal Is only for the structural engineering <br />th drawing pages bearing Engineer's signature <br />and seal. <br />Z <br />0 cu <br />1­1 <br />C:) <br />V) <br />> U-) rn <br />en <br />M Lr) <br />0 <br />Z <br />0) In <br />U <br />Cn <br />U —4 <br />00 <br />E <br />W <br />Z 3: M <br />Z <br />UJ C> <br />—1 0 <br />Milli <br />Z< <br />Z <br />r, 8 00 <br />0 Ce <br />a <br />g UZ. <br />J1 <br />< <br />68�j,z <br />F 8! 6.j <br />8 Lic <br />0c) <br />> <br />00 <br />r-, <br />F— <br />Z <br />0 <br />Uj <br />'n <br />Lr) <br />Uj <br />Cr_ <br />0 <br />U <br />:r <br />C <br />Iso <br />0 <br />0 <br />99 <br />J <br />a. <br />_j <br />U_ <br />< <br />r-4 <br />< <br />i <br />zW <br />Z <br />Z <br />IJJ <br />Lij <br />di <br />X <br />65-0 <br />" � 10 <br />T-1 <br />M <br />(=) <br />X <br />< <br />Z <br />< <br />Z <br />t- <br />0 <br />11�4 <br />00 <br />Z <br />U <br />UJI <br />rn <br />T-4 <br />SCALE AS NOTED <br />DATE 1/4/2018 <br />TECH: ERAND <br />VERSION No - 10 <br />SHEET NO. <br />4.0 <br />