OPTIONAL OVERHEAD SERVICE SAME AS
<br />150 : I COPPER OR 2/0 ALUMINUM
<br />UNDERGROUND 150 OR 200 AMP SERVICE
<br />200 - 2/0 COPPER OR 4/0 ALUMINUM IN 2" CONDUIT.
<br />TYPICAL �A/
<br />MAIN D15C. ELECTRICAL Di5CONNECT
<br />ii
<br />150 OR PANEL
<br />REFER TO FLOOR PLAN FOR
<br />200 AMP M2 COPPER TO APPLIANCES AND GFI
<br />NOTED AMPS. REQUIRED
<br />L --------- i M4 COPPER TO LIGHTS AND OUTLETS
<br />`10 COPPER TO WATER �EATER
<br />UNDERGROUND SERVICE
<br />*6 COPPER TO RANGE
<br />BY POWER COMPANY
<br />% COPPER TO HVAC
<br />*4 GROUNDING WIRE WITP CODE
<br />APPROVED CLAMP PER 25050
<br />AND 25052 OF THE 2014 NEC,
<br />INTER5Y5TEM "DING TEWINATION PER NEC 08, 250.54
<br />ELECTRICAL RISER DIAGRAM_
<br />NOTE:
<br />ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W1 APPLICABLE PROV15ION5
<br />OF THE NFPA 10-08, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY
<br />5TAIR NOTE5
<br />RAILING
<br />BALUSTERS SHALL BE 5PACED 50 THAT A 4" SPHERE CANNOT PA55 THROUGH.
<br />HANDRAILS
<br />HANDRAIL5 FOR 5TAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP R15ER OF
<br />THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST R15ER. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR
<br />SAFETY TERMINALS. HANDRAIL5 ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LE55 THAN 1-1/2 INCH BETWEEN THE WALL AND HANDRAIL5.
<br />CONTINUOUS GRASPABLE HANDRAIL MUST MEET TYPE ONE OR TYPE TWO CRITERIA
<br />UNDER-5TAIR PROTECTION
<br />ENCL05ED ACCE551BLE SPACE UNDER STAIRS SHALL HAVE WALL5, UNDER-5TAIR SURFACE AND ANY SOFFIT PROTECTED ON THE
<br />ENCL05ED 51DE W1 1/2 INCH GYPSUM BOARD PER F.B.C. RE51DENTIAL bth EDITION (2011) - R3021 AND R302.11
<br />5TAIRWALL FRAME NOTE
<br />ALL STAIRWELL SURROUNDING WALLS AND KNEE WALLS AIRE TO BE FRAMED AT IV' O.C. TO PROTECT FROM FALLING HAZARD
<br />OCCUPANCY AND CON5TRUCTION TYPE:
<br />TH15 UNIT HAS AN R3 OCCUPANCY AND BUILDING TYPE V-5 CLASSIFICATION,
<br />CEILING CON5TRUCTION:
<br />1. THE GARAGE SHALL BE SEPARATED FROM THE RE51DENCE AND ITS ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD APPLIED
<br />TO THE GARAGE 51DE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS A50VE BY NOT LE55 THAN
<br />5/8 INCH (5.9 mm) TYPE `X" GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION 15 A FLOOR -CEILING ASSEMBLY, THE STRUCTURE
<br />SUPPORTING THE SEPARATION SHALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM E30ARD OR EQUIVALENT,
<br />DWELLING / GARAGE OPENING5:
<br />1. THE OPENING BETWEEN THE GARAGE AND LIVING AREA SHALL BE EQUIPPED WITH 50LID WOOD DOORS NOT LE55 THAN 13/6' IN THICKNESS,
<br />50LID CORE (5.C;.) OR HONEYCOMB GORE STEEL DOORS NOT LE55 THAN 13/5" THICK, OR 20 MINUTE FIRE RATED DOORS.
<br />2, ALL DOORS FROM GARAGE ADJACENT TO LIVING SPACE MUST BE EITHER A SOLID CORE DOOR OR HAVE A MIN. FIRE RATING OF 20 MINUTES.
<br />EGRE55:
<br />EACH BEDROOM MUST PAVE ONE WINDOW THAT COMPLIES WITH EGRE55 CODES, IF THERE 15 NO ACCE55 TO EXTERIOR THROUGH A DOOR. THE
<br />WINDOW MUST HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15P FLOOR LINE OF THAT PARTICULAR ROOM.
<br />WINDOW IN5TALLATION:
<br />WINDOWS 5HALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN
<br />INSTALLATION IN5TRUCTION5 SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW,
<br />TERMITE PROTECTION:
<br />1. PENETRATION, PROTECTIVE 5LEEVE5 AROUND PIPING PENETRATING CONCRETE 5LAB-ON-GRADE FLOORS SHALL NOT BE OF CELLUL06E
<br />CONTAINING MATERIALS. IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL HAVE A MAXIMUM WALL
<br />THICKNE55 OF 0,010 INCH, AND BE SEALED WITHIN THE SLAB U51NG A NON-CORRO51VE CLAMPING DEVICE TO ELIMINATE THE ANNULAR SPACE
<br />BETWEEN THE PIPE AND THE SLEEVE, NO TERMITIGIDE5 SHALL BE APPLIED IN51DE THE SLEEVE.
<br />2. PROTECTION AGAINST DECAY AND TERMITES, - CONDENSATE LINES, IRRIGATION / SPRINKLER 5YSTEM RISERS FOR SPRAY HEADS, AND ROOF
<br />DOWN5POUT5 SHALL D15CHARGE AT LEAST I FOOT (305 mm) AWAY FROM THE STRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL
<br />EXTENSIONS, OR 5PLA5H BLOCKS. GUTTERS WITH DOWN5POUT5 ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LE55 THAN (o INCHES (152 mm)
<br />HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF A50VE ANOTHER ROOF.
<br />I
<br />TOP RAILING NOTE: SUBFLOOR ADPE51VE 15 USED IN ADDITION
<br />BALU5TER5 TO NAILS ON WOOD COMPONENTS.
<br />MAX SPACING 4"
<br />1 X 0 PAINTED WD. CAP STRINGER 15 LAMINATED TO A THICKNE55 EQUIVALENT TO
<br />OGEE STOP THE 51ZE OF A 2 X 12 5,Y,P. AND 15 NAILED TO EACH
<br />TREAD W1 I(od NAILS FROM THIRD LAMINATE TO TREAD—,
<br />OPT. 2 X 2 BLOCKING NAILED
<br />TO TREAD AND RISER,
<br />3-2 X 12 STRINGER 2 X BLOCKING NAILED TO STRINGER, +1
<br />3/4" R15ER5 R15ER, AND TREAD, +
<br />2 X TREADSi RIP FROM 2xI2 I X SPRUCE *3 OR 3/411 C;DX, + +
<br />TO SIZE NOTED ON PLAN PLYWD. R15ER.
<br />2 X SOUTHERN YELLOW PINE 01
<br />(ACTUAL THICKNE55 15 11/2 ") TREAD.
<br />TYP. OPT. RAILING ELEVATION-
<br />6CALE: 1/2" -- I'-0.
<br />NEEL P05T
<br />TOP RAILING
<br />5ALU5TER 411 O.C.
<br />SHOE RAIL (REMOVE
<br />W1 METAL SPINDLES)
<br />I X 6 PAINTED WD. CAP
<br />OGEE STOP
<br />�L.Q-UX LINt
<br />OPTIONAL
<br />rA-,RAI.LING DETAIL
<br />r
<br />CLOSED RISER DETAIL
<br />C-r-ALE: 1/2" -- 1'-0"
<br />CARPI
<br />GARPf
<br />TREAC
<br />R15ER
<br />2 X 4 WALL
<br />1/21, GYP 5D,
<br />3/4" SKIRT 5D.
<br />2 X 4 SPACER
<br />I H 2 X 12
<br />TyN I STRINGER
<br />PICAL STAIR
<br />FRAMING DETAIL
<br />5CALE; 3/411 - I'-011'
<br />GENERAL CONSTRUCTION NOTES_
<br />CHAPTERS AND SECTIONS REFER TO F.B.C, RESIDENTIAL (oth EDITION (2011)
<br />MECHANICAL AND PVAG
<br />1. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FUW15HED BY THE GENERAL CONTRACTOR AS AN ATTACHMENT TO
<br />TH15 PLAN SET AT THE TIME OF APPLICATION FOR PERMIT.
<br />2. MECHANICAL APPLIANCES SHALL BE ACCE551BLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT
<br />CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING IN5PECTED, 5ERVICED,
<br />REPAIRED, OR REPLACED, A LEVEL WORKING SPACE AT LEAST 30 INCHES (162 mm) DEEP AND 30 INCHES (162 mm) WIDE SHALL BE PROADED IN
<br />FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE.
<br />3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE
<br />CONSTRUCTED OF A MIN. 126 GAUGE (0,48 mm) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE,
<br />4. FOUNDATIONS AND 5UPPORT5 FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RA15ED AT LEAST 3 INCHES (16 mm) ABOVE THE FIN15HED
<br />GRADE AND SHALL AL50 CONFORM TO THE MANUFACTURER'5 INSTALLATION INSTRUCTIONS.
<br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDEN51NG APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO
<br />ANY BUILDING COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM, THESE PANS SHALL BE
<br />INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTIONS M1411.3.
<br />EXHAU5T FAN5 AN[) VENTING:
<br />1. OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE D15CHARGED TO THE OUTDOORS, AIR SHALL
<br />NOT BE EXHAU5TED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE.
<br />2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND
<br />SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC,
<br />CRAWL 5PAGE, OR OTHER AREAS IN51DE THE BUILDING.
<br />3. DUCT LENGTH. THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE
<br />WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 25 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAD) BEND
<br />AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (lb RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRAN51TION
<br />DUCT.
<br />EXCEPTION - WHERE A CLOTHES DRYER 5005TER FAN 15 INSTALLED AND L15TED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF
<br />THE EXHAUST DUCT, INCLUDING ANY TRAN51TION DUCT, SHALL BE PERMITTED TO BE IN ACCORDANCE WITH THE E3005TER PAN MANUFACTURER'S
<br />INSTALLATION IN5TRUGTION5, WHERE A CLOTHES DRYER 5005TER FAN 15 INSTALLED AND NOT READILY ACCES515LE FROM THE ROOM IN WHICH
<br />THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE THE EXHAUST DUCT ENTERS THE WALL. THE
<br />LABEL SHALL BEAR THE WORDS 11TH15 DRYER EXHAUST 5YSTEM 15 EQUIPPED WITH A REMOTELY LOCATED E3005TER FAN.11
<br />4. PROVIDE LOUVER DEVICES AT INTAKE AND EXHAUST LOCATIONS IN ACCORDANCE WITH
<br />AMCA STANDARD 550 IN F15C,
<br />ROUGH- IN IN5PECTION REQUE5T NOTE
<br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGk-IN5 MUST BE
<br />COMPLETE, INSPECTED AND APPROVED BEFORE REQUESTING THE
<br />FRAMING INSPECTION.
<br />WINDOW FALL PROTECTION
<br />IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW 15
<br />LOCATED MORE THAN 12 INCHES ABOVE THE FIN15HED GRADE OR
<br />SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE
<br />WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED
<br />FLOOR OF THE ROOM IN WHICH THE WINDOW 15 LOCATED. OPERABLE
<br />SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW
<br />PA55AGE OF A 4 INCH DIAMETER SPHERE WHERE SUCH OPENINGS
<br />ARE LOCATED WITHIN 24 INCHES OF THE FIN15HED FLOOR PER F.B.C.
<br />RESIDENTIAL bth EDITION (2011) - SECTION R3121,
<br />WINDOW FALL PREVENTION DEVICES AND WINDOW GUARDS, WHERE
<br />PROVIDED, SHALL COMPLY WITH THE REQUIREMENTS OF A5TM F 2090
<br />PER F,B.C. RESIDENTIAL (oth EDITION (2011) - SECTION R3122.
<br />IN5ULATION NOTE5
<br />• CMU WALL& ----- R-FOIL 4.1 KNEE WALLS THAT
<br />BACK UP TO CEILING
<br />• FRAME WALL& -------- R- 13 AREA ONLY: ----------- R-19
<br />9 CEILING: ------------- R-30
<br />ON51TE FOUNDATION 5URVEY NOTE
<br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE
<br />SURVEY SHALL BE ON THE 51TE FOR THE BUILDING IN5PECTOR'5 USE,
<br />OR ALL PROPERTY MARKERS SHALL BE EXP05ED AND A STRING
<br />5TRECHED FROM MARKER TO MARKER TO VERIFY REQUIRED
<br />SETBACKS.
<br />CELiNG AT ENTRY NOTE
<br />ALL ENTRY CLG5. TO BE 15/32 056. CEMENTITOU5 FIN15H (UN.0)
<br />GA5 APPLIANCE PROTECTION IN GARAGE NOTE
<br />PROTECTION OF GAS APPLIANCES IN RESIDENTIAL GARAGES:
<br />MINIMUM 3" DIAMETER 5CP 40 STEEL PIPE, 2 FT. BELOW CONCRETE
<br />SLAB AND 3 FT. ABOVE FIN15HED FLOOR
<br />GENERAL NOTE5
<br />DUE TO VARIATIONS IN CITY REQUIREMENTS, SUBDIVISION
<br />SPECIFICATIONS, CONSTRUCTION TECHNIQUES, DIVER51TY IN
<br />MATERIALS, AND PLAN REVISIONS, ALL DIMENSIONS AND
<br />ELEVATIONS MAY VARY PER INDIVIDUAL PLAN. ACTUAL FIELD
<br />CONDITIONS MAY VARY AND MUST BE VERIFIED BEFORE
<br />PROCEEDING WITH CONSTRUCTION.
<br />• ELECTRICAL LOCATIONS 5PM ON DRAWINGS MAY BE CHANGED
<br />AT THE 50LE D15GRETION OF CALATLANTIC HOMES OR ITS
<br />LICENSED ELECTRICIAN IN ORDER TO COMPLY W1 NATIONAL AND
<br />MUNICIPAL BUILDING AND ELECTRICAL CODES. CALATLANTIC
<br />HOMES WILL NOT GUARANTEE LOCATION OR QUANTITY OF OUTLETS
<br />AND / OR SWITCHES SHOWN.
<br />• ALL PLUMBING DIMENSIONS ARE APPROXIMATE FROM THE CENTER
<br />LINE OF THE FIXTURE TO THE EXTERIOR SLAB EDGE. IT 15 THE
<br />RESPONSIBILITY OF THE PLUMBER TO VERIFY THE ACCURACY OF
<br />ALL PLUMBING DIMENSIONS.
<br />NOTE: ANY DIMEN51ON5 AND/OR CALLOUTS WITHIN TH15 SET OF DRAWINGS REFERENCING
<br />LUMBER SIZES OR WALL THICKNE55E5 ARE TO BE CON511DERED "NOMINAL DIMENSIONS"
<br />CHIMNEY HEIGHT REQUIREMENT5:
<br />WHEN STANDARD OR OPTIONAL FIREPLACE 15 TO BE INSTALLED THE CHIMNEY MUST EXTEND 34" PAST THE HIGHER POINT WHERE IT
<br />EXTENDS THROUGH THE ROOF AND MUST BE 24" HIGHER THAN THE ROOF OR RIDGE THAT 15 104" AWAY OR CLOSER.
<br />TUB AND 5HOWER AREA5:
<br />CEMENT, FIBER -CEMENT, OR GLA55 MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH A5TM C1288, C1325, OR G1118
<br />AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE USED AS BACKERS FOR WALL TILE IN TUB AND
<br />SHOWER AREAS, AND WALL PANELS IN SHOWER AREAS.
<br />FLOOD ZONE REQUIREMENT&
<br />PLAN MEETS OR EXCEEDS FEMA FLOOD FIN15HED GARAGE FLOOR ELEVATION,
<br />I I -i
<br />DAVIS BEWS
<br />DESIGN GROVP
<br />L50 STATE STFLEET EAST
<br />OLDSMM, FLOMA W77
<br />813. 925. L300 TEL
<br />813. 925. 1800 FAX
<br />WWW�DAVL%EWS.COM
<br />T,kh4PA o r>ENVEP—
<br />ES`T. 1994
<br />0
<br />0
<br />r4
<br />0 cu
<br />14
<br />V) :L-! C)
<br />14 = %0
<br />z> cn
<br />cn c�
<br />(0 Ln
<br />o< U)
<br />z< LL
<br />F-
<br />Q� u
<br />< § E
<br />z
<br />w z
<br />Lu
<br />_j
<br />�z
<br />'z
<br />z g,,a-
<br />Lu < x
<br />� z 8 0
<br />V) 0 0
<br />�E Z. Z.
<br /><
<br />LL
<br />W
<br />V)
<br />oz
<br />z z
<br />z
<br />D
<br />0
<br /><
<br /><
<br />b F-4
<br />F-
<br />D z
<br />u-
<br />Lu
<br />z < CD
<br />< 0 r-4 LU
<br />z %---, .� 0
<br />z U z z 0
<br />uj
<br />0 u
<br />Lu z F-
<br />m: 0 z
<br /><
<br />z Lu
<br />z
<br />0 5
<br />rn a- uj to7
<br />ca
<br />SCALE AS NOTED
<br />DATE 10-19-2018
<br />VERSION NO.
<br />iso
<br />SHEET NO.
<br />DT1
<br />
|