Laserfiche WebLink
0 <br />CN <br />L0 <br />cc <br />C1 <br />CJ4 <br />C'4 <br />K) <br />0 <br />CN <br />LO <br />cc <br />4% <br />C <br />E <br />EZ <br />CL <br />t-ULU UP WEATHER <br />RESISTIVE BARRIER & <br />WEATHER RESISTIVE <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />TEMPORARILY SECURE <br />BARRIER <br />DOOR ROUGH OPENING <br />WEATHER <br />SLOPE <br />7 RESISITIVE <br />0.3 in: 12.0 in <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />BARRIER <br />TAPE <br />EXTERIOR <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHING <br />3/4" 1" BEAD OF CONSTR. <br />(0. 6 cm 30.5 cm) <br />R703.2 Weather -resistant sheathing paper. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />SHEATHING <br />BY LAPPING DOWN <br />OVER RIM JOIST AND <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />SELF -ADHERED FLASHING <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />LIF <br />WALL BY 6 IN. <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />With the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />(ASSEMBLED WNDOW) <br />(2Y <br />OR EQUAL WEATHER PROOF CAULKING <br />EXTERIOR <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />2 <br />CEMT. FIN. <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />WEATHER <br />SELF -ADHERED FLASHING <br />BUILDING PAPER <br />RESISITIVE <br />& <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />BARRIER <br />SEAL TOPS OF JOISTS <br />WIRE LATH <br />1. In detached accessory buildings. <br />UNDER DECKING <br />SUBFLC <br />SUBFLOOR <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />SELF -ADHERED FLASHING <br />(SEE DETAIL WP07) <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />I <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />1 . Cut, fold up & temporarily secure weather resistive <br />RIM JOIST <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />iESE DETAILS ARE GENERIC AND <br />barrier above header to allow for flashing <br />N <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />installation <br />:-ANIT TO SHOW GENERAL FLASHING <br />4D WATERPROOFING METHODS TO <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />P <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface ot he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more ofthe <br />3. Fold weather resistive barrier back over head <br />A <br />USED. <br />flashing and seal with tape <br />V N, <br />Q <br />following or other approved method: <br />1. 1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />Scale: NTS <br />SELF -ADHERED FLASHING <br />FLANGED WINDOW <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />1.3 In accordance With FMA/AAMA 100, FMA/AAMA 200, or FMAIWDMA 250. <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR DOOR WITH DECK - SECTION A <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />EXTERIOR SHEATHING <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHAL <br />RUBBERIZED <br />4. Continuously above all projecting wood trim. <br />EXTERIOR SHEATHING <br />314"-l" BEAD OF CONSTR. <br />INSTALL SELF -ADHERED <br />NEEDED IN CORNERS ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />FLASHING JAMB & HEAD <br />FLASH NG, SEE <br />FLASHING SELF -ADHERED FLASHING <br />6. At wall and roof intersections. <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />FLANGED WINDOW <br />7. At built-in gutters. <br />OR EQUAL WEATHER PROOF CAULKING <br />(SEE DETAIL WP01) <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />SCORED <br />R703.6.2.1 Weep Screeds <br />COMPATIBILITY <br />RELEASE PAPER <br />A Minimum 0.01 9-inch (No. 26 GaIv. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING, <br />(BEFORE FOLDING, SCORE <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />EXTEND A MINIMUM 6" <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />SECTION -A (SEE DETAIL WP02)--,, <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />2 <br />SELF -ADHERED FLASHING <br />5 <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />NAILING FLANGE <br />1 <br />14 <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />@ <br />DO NOT FLASH OVER <br />2 <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />6 <br />Detail Instructions <br />Refer to the detail <br />E) in <br />BOTTOM NAILING <br />8 <br />(SEE DETAIL WP07) <br />7 <br />number marked as each that corresponds to the numbered items in the list of <br />FLANGE <br />instructions below: <br />1 . Install self -adhered flashing in order as shown by numbers <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING IF <br />MIMI <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />EXTERIOR DOOR WITH DECK <br />INSIDE CORNER <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />Ground <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />SHEATHING <br />piece of flashing material (15" x 6" Minimum) <br />/1Zf <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to flt tight to corner <br />8. Mechanically fasten as necessary <br />Lath <br />SELF -ADHERED FLASHING <br />Sheathing <br />PATCH <br />stucco <br />d 'ZIN <br />7/8" Cement Plaster <br />DOUBLE <br />4 <br />in accordance With <br />JOIST <br />4 <br />ASTMC926 <br />7/8" Cement Plaster <br />SINGLE <br />WOOD BEAM <br />Foundation Wall <br />Felt backed metal in accordance with <br />I <br />JOIST <br />BELOW <br />SELF -ADHERED <br />FLASHING <br />lathe in accordance ASTMC926 <br />SELF -ADHERED FLASHING <br />4. 4 <br />with ASTMC 1063 <br />2 <br />"k Felt backed metal <br />3" MIN <br />Building Paper lathe in accordance <br />SELF -ADHERED <br />SELF -ADHERED <br />4 <br />with ASTIVIC 1063 <br />FLASHING <br />FLASHING <br />Q <br />5 <br />7/16" O.S.B. <br />sheathing Building Paper <br />7/16" O.S.B. <br />Metal sheathing <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />CORNER <br />FOUNDATION WEEP SCREED <br />Flashing <br />DECK JOIST <br />OUTSIDE <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />-7 <br />Maintain <br />A STRIP OF SAF <br />LEGEND <br />Bottom of Stampede or similar <br />Weep Screed cauk bottom <br />SELF ADHERED FLASHING (SAF) <br />1 1/211 to 211 joint only <br />DRAINAGE PLANE WRB <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />Above Roof <br />BARRIER (WRB) - - - - - - - <br />Weep Screed <br />-BOND BREAK WRB <br />BOND BREAK WEATHER RESISTANT BARRIER- <br />Sheathing Installed As Per <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />Manufact. Specs. <br />SF LATH <br />SHEATHING, 'OSB', PLYWOOD, DENSGLASS <br />WRAP DP WRB ONTO <br />1/2" Cementitious <br />Cement Plaster <br />THE VERTICAL <br />Decorative Finish <br />in accordance <br />lk <br />SURFACE TO TOP OF <br />I FLANGE AS AN AIR <br />with ASTMC926 <br />All inside and <br />BARRIER <br />over wood 2nd <br />floor outside comer Will <br />3-1/2" INCH FLANGE <br />need to be miter <br />I <br />I <br />�J <br />cut and caulked all <br />buff joints need to <br />STRUCTURAL FRAMING <br />becaulked using <br />Stampede or sim. <br />STRUCTURAL SHEATHING <br />caulk for all <br />PLASTER STOP <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />STRIP OF SAF <br />DO NOT SEAL. <br />CONTINUOUS BACKER <br />-��DRAINAGE PLANE WRB <br />ROD & SEALANT <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />JBOND BREAK WRB <br />7 <br />SF LATH <br />Note: <br />------------ <br />The building paper and metal lath must be <br />Cement installed over the top of the weep screed. <br />a <br />Plaster <br />--------------- <br />0 PLASTER STOP <br />over block <br />CONTINUOUS BACKER ROD <br />1 st floor <br />& SEALANT <br />CEMENTITIOUS FINISH <br />WEEP SCREED DETAIL <br />NOT USED <br />SOFFIT/CANTILEVER <br />SCALE: NOT TO SCALE <br />7 0 <br />5q <br />0 <br />0 r <br />cr) <br />-8 <br />V1 I-D <br />QJ Z; <br />4--J , <br />Yu in <br />0 "L.. <br />4 <br />LU <br />C., <br />C14 <br />C,4 <br />CL, <br />So <br />FZ' <br />CD <br />W5 :!!� <br />0 <br />A I <br />ED. <br />N-C-8-DLC <br />F_ a <br />U) C-1 Sr! <br />C', <br />fn <br />LU ie <br />us <br />Z 0 U3 <br />fA -9 <br />Z 4n JV! -5 <br />LU 44 <br />WWW.FDSENG.COM 00 <br />C14 <br />C=) <br />To the best of the Engineer's knowledge, inforniation and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential ft Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />Lu <br />Z g <br />C/) <br />'00': <br />01M <br />< <br />e-s <br />< <br />LL1 <br />0 <br />Z <br />Z <br />0 <br />_0 <br />1�*� <br />0 <br />0 <br />0 <br />Q) <br />> <br />U <br />(1) <br />r"4 <br />LU <br />< <br />0 <br />Z <br />00 <br />Lu <br />Z <br />LLJ <br />Ln <br />Lij <br />d'z 8 <br />Ln <br />r.J <br />Z <br />Z <br />0 <br />Z <br />ul <br />Is <br />0 <br />C) <br />Ck <br />Z <br />LU <br />U) <br />S <br />SCALE AS NOTED <br />DATE 11/2/2018 <br />TECH: KFRAZER <br />VERSION No. 42 <br />SHEET NO. <br />W P <br />