My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35926 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35926 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:11:20 PM
Creation date
2/19/2025 10:46:43 AM
Metadata
Fields
Template:
Building Plans
Street #
35926
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
21011
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />I- - . � _'�J'_b4u - 1� — — __ I I . 11 - — A" — , I � _. m I . � Iii, _' III . :: 1. 1 1 1 . — '_ __ - — �' — I 1 .1 1� I . . - - MEMMOM�" j - I .__L <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY! <br />BON <br />TERMINATIOIN <br />NEC 14, 250.94 -/ <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />*perto fights& outlets <br />Dpper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />t Aju <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 116" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39"AFF <br />laundry room 36" AFF <br />exterior waterproof 12"AFF <br />garage general purpose 42"AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power soui ce and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped With an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible Warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where i1stalled <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a Washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to filfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />0=� <br />r4Z:;I_ <br />DUPLEX CONVENIENCE OUTLET <br />I A�� <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />L4:4- <br />r1=0W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />piiip <br />HALF -SWITCHED DUPLEX OUTLET <br />1 L91% <br />SPECIAL PURPOSE OUTLET <br />rw <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />I-0 <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />2—M <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />nCH <br />CHIMES (OPTIONAL) <br />01 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />E <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />US13 <br />TELEPHONE/USI3 (OPTIONAL) <br />E <br />fq <br />TELEVISION (OPTIONAL) <br />0 <br />C) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />_N*__j <br />ROUGH -IN FOR OPT. CEILING FAN <br />�3 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />69 (1) PHONE LINE, (1) DATA PORT <br />ENTRY LIGHT <br />AS PER SPECS <br />Erva-1 <br />ON n-A <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=l'-O" <br />0 0 <br />< <br />__j <br />V) 0 <br />C-/> <br />LU <br />-a) 0 LU <br />(A <br />LA <br />LU <br />I -A <br />em <br />CP M <br />�i_@Cq <br />125 *8 " <br />0 <br />8. <br />< <br />-C 6 <br />A 1 <br />BID. <br />#A <br />LU <br />U) Isse <br />14 U_ <br />us <br />cis <br />Z 0 V., <br />qn,f t �� Z5 <br />to r- 4, <br />Z U)M!l <br />pt <br />LU f <br />6 W <br />Q U <br />VAM.FDSENG,COM 0 U <br />LO <br />4=) <br />To that best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and sea] is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Z <br />0. <br />U;r 0 <br />P . 0 <br />8 �8 <br />12 @ <br />0 <br />0 <br />i U <br />z <br />I <br />Z <br />'0 <br />%%-000 <br />L.0 <br />_j <br />L.0 <br />4 <br />X <br />> <br />0 <br />U <br />Ln <br />r*4 <br />0 <br />0 <br />LL <br />n <br />flP P <br />Ran <br />r-4 <br />< <br />un <br />Z <br />00 <br />Z <br />r4 <br />Ln <br />Lij <br />.2 ti <br />Z <br />ad� <br />< <br />< <br />Z <br />.." <br />In <br />fn <br />C:) <br />Ck <br />Z <br />Z <br />tu <br />U.j <br />LU <br />0 <br />SCALE AS NOTED <br />DATE 11/2/2018 <br />TECH: KFRAZER <br />VERSION NO - 42 <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.