ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE PPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42"AFF <br />range 2"AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power sourc* and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />I Z7!L. <br />FEF <br />DUPLEX CONVENIENCE OUTLET <br />I zi!�_ <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />1 Z7!1.. <br />FE�W.p. <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />Cn <br />Fiiw: <br />HALF -SWITCHED DUPLEX OUTLET <br />I jr-h <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />C14 <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />LO <br />cc <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />)C�LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />@) <br />60 <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />C, <br />C4 <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FCHJ <br />CHIMES (OPTIONAL) <br />c14 <br />-k <br />FH <br />PUSH BUTTON SWITCH (OPTIONAL) <br />E <br />PUSH BUTTON SWITCH - DOOR BELL <br />E <br />@ <br />SMOKE DETECTOR <br />0 <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />0 <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60- A.F.F. <br />THERMOSTAT <br />0- <br />,<1 <br />CL <br />R9 <br />ELECTRIC METER <br />ELECTRIC PANEL <br />15? <br />DISCONNECT SWITCH <br />-JIIIIIIII-A <br />ROUGH -IN FOR OPT. CEILING FAN <br />C\ <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />QD <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />CENTER <br />NEMA 1 <br />200 AMP <br />METER _T <br />MAIN <br />0 <br />200 amp <br />150 amp =j <br />POWER CO. FEED---" <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14,250.94 <br />$14 copper to lights& outlets <br />#12 copper to 20 amp cirts <br />10-2 copper to WH <br />10-3 copper to Dryer <br />or 410 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />IF --------------------------------------------------------------------------------------------------- <br />UPPER ELECTRICAL PLAN <br />SCALE: Y4"=l'-O" <br />__j <br />V) 0 <br />Q) C—/> <br />4-J LU <br />C) <br />0 LLJ <br />LU <br />C.4 <br />0 <br />ILL Go <br />A <br />a FD. <br />t"'s" <br />8! C" <br />F" w. Z <br />lu <br />Z <br />1 <br />?5 <br />Z Ul <br />LLro <br />ju .4 IQ <br />(ti " , 2 <br />WAMMSENG.COM Li Li <br />C:) <br />To the best of the Engineer's knowledge, information and belief, - <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential Oth Edition, Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Z <br />13 <br />8 <br />0 <br />Z <br />'0 <br />Z <br />> <br />ILILI <br />0 <br />U <br />U-) <br />1 <br />LU <br />Uj <br />I- r <br />�96 <br />LU <br />00 <br />V- <br />< <br />t <br />I <br />Z <br />Z <br />W <br />rA <br />Ln <br />Lij <br />�: <br />0.,!i <br />�Z§ <br />_j <br />V-q <br />LU <br />2: <br />< <br />Ln <br />< <br />Z <br />Z <br />V) 9 <br />Cal <br />0 <br />LU <br />Z <br />Lu <br />9 <br />rn <br />0- <br />SCALE AS NOTED <br />DATE 11/2/2018 <br />TECH: KFRAZER <br />VERSION NO - 42 <br />SHEET NO. <br />4.2 <br />