36101 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36101 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:37:05 PM
Creation date
2/19/2025 10:49:07 AM
Metadata
Fields
Template:
Building Plans
Street #
36101
Location
Stable Wilk Ave
Contractor
Lennar Homes LLC
Building Plans - Permit #
18398
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />NEMA 1 <br />200 AMP #12 copperto 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />MAIN A-L <br />or 4/0 SER Alu <br />0 <br />200 amp <br />150 amp ===1F210 <br />Disconn <br />POWER CO. FEED <br />_Inset <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />*4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 08, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I ELECTRICAL KEY I <br />I 0=� <br />tkz�;,- <br />DUPLEX CONVENIENCE OUTLET <br />I Z±�, <br />PEPP <br />DUPLEX OUTLET ABOVE COUNTER <br />�I@W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />@) <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />MQ <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />PH] <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SMOKE DETECTOR <br />SMCKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60- A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />1> <br />ROUGH -IN FOR OPT. CEILING FAN <br />/> <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br /></ <br />OPT. CEILING FAN <br />G9 <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />GFI V <br />FI FI: V <br />VERIFY LOCATION IRRIGATION <br />r <br />OPT. ELECTRICAL PANEL — — — — — — — — — — — — <br />REF. GFI @ 44" A.F.F. <br />I L <br />T— <br />KITCH <br />EN <br />W <br />D <br />.1P <br />—QG FF I <br />Li Lil GFI FOR I <br />GFI @ 44" GAR. DOOR <br />GFI <br />A.F.F. <br />WP <br />GFI <br />9 2 CAR GARAGE <br />PATIO DINING ROOM <br />,/PENDANT AS 0 1 L <br />PER SPECS GFI @ 44" <br />Cq A.F.F. <br />Cl) W.H. <br />J, CE <br />`4P <br />Z7 <br />FOYER <br />TR)�I <br />-db- <br />----------- <br />rn <br />qp <br />WP <br />7 GFI <br />ROUGH -IN FOR 01, <br />OPT. CLG. FAN/ 1000 <br />LIGHT PRE -WIRE <br />FLEX <br />WP FAMILY ROOM — TO 2NDCj� <br />GFI 317-1 FLR. I <br />100, ROUGH -IN FOR <br />OPT.CLG.FAN/ <br />DISCONNECT LIGHT PRE -WIRE <br />7/— <br />I 1—, 4 <br />(C 0 ND. <br />db <br />LVTT7TTTTIIIIIIIIIIIIIIIIIIIIilililI 1111111111 1111mill,11+111+111111111 111111711111111111111111771111111111 <br />H.B. <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"= V-0" <br />(D <br />Ul) (D <br />Q) C—J0 <br />4—J LU <br />ru <br />0 LU <br />0 <br />CO <br />C\I <br />a) co <br />0) M <br />C M co <br />E <br />0 <br />cc "0 n <br />6'i= N <br />0 <br />to <br />C) <br />LL 00 <br />:3 <br />0_,[,_ <br />U5 <br />-�e <br />< 0 <br />LO 0 -'T <br />N C B D C <br />La <br />6 <br />010 <br />Ci <br />Z Cql` <br />W 4W 2 'T <br />__A __j <br />LL Lj-__j <br />I U- <br />08% <br />.a LL 0 <br />,= 0 <br />W CL <br />CH <br />LLI <br />PE, <br />0 <br />c� (5 <br />'6 of-- 0 <br />E B <br />0 <br />2 <br />Z <br />W 012 <br />< <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />C:) <br />0 <br />Z C-4 <br />0 cu <br />f <br />01 4-J C:) <br />V) 1 53 �0 <br />C:) <br />> V) rn <br />C) <br />M <br />U-) f0 Lr) <br />:2. q1- <br />Z <br />cl. w <br />(A 0 rl� <br />a) — Ln <br />L- LL <br />CL o-'s <br />, <br />170 <br />ce U a- OC) <br />Z <br />< <br />Z § E <br />Z 170 <br />Lu C) <br />—.1 <br />W <br />0, <br />U0, <br />Z <br />Z <br />17 <br />Z <br />>- <br />< <br />C, 0 <br />U <br />Z <br />Z Z <br />Lu Z <br />� LH <br />8 �y u 8 <br />" <br />03 l- <br />EE <br />0- Lon <br />Z Z <br />Lr) <br />0 <br />U <br />Z <br />uj <br />Z <br />0 <br />-0 <br />LU <br />Ln <br />fu <br />Lr) <br />LU <br />CC <br />Z <br />0 <br />0 <br />U <br />0 <br />LL <br />LU <br />< F0 0 <br />Z <br />0- <br />rj <br />0 < <br />Z <br />1Z <br />< <br />< <br />F- LU OW <br />0 cg <br />1) <br />Z <br />0 <br />Z <br />LU <br />Ln <br />6j <br />CY u- <br />u" 20: �Z- <br />N-c - <br />2: <br />< <br />Z <br />on <br />OZ8 <br />2 <br />w N < <br />LLI 8 <br />Z <br />Z <br />Z <br />tu— <br />(A Z <br />0 <br />LU <br />< Ln <br />Z <br />LU <br />17-11 <br />13- <br />U0 <br />In <br />SCALE AS NOTED <br />DATE 2/24/2014 <br />TECH: WAMES <br />VERSION No' 10 <br />SHEEr NO. <br />4.0 <br />