My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36484 Flats St
Zephyrhills
>
Building Department
>
Building Plans
>
36484 Flats St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:04:59 PM
Creation date
2/19/2025 10:51:09 AM
Metadata
Fields
Template:
Building Plans
Street #
36484
Location
Flats St
Contractor
Lennar Homes LLC
Building Plans - Permit #
5972
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
02 <br />0 <br />:9 <br />L0 <br />4M <br />1.0 <br />U*) <br />f14 <br />M <br />q�, <br />L0 <br />C"' <br />2 <br />CD <br />CD <br />5,4 <br />S. <br />E <br />EE <br />C-4 <br />C) <br />C14 <br />CL <br />C'4 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANELCENTER <br />10 #14 to fightS & outlets <br />NEMA 1 01 #12 to apptiances and GF1 <br />1 50 AMP/ <br />200 AMP 00 #10 to WH <br />0 #8 to Range <br />01 #6 to HVAC <br />ME ER <br />M T N T <br />T/--150=2/0 <br />n 200=4/0 In 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND IDIs <br />SERVICE BY POWER CO.---,_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17,250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />1. Electrical outlet heights as measured from finished floor to mer 11ne ol [Ile IJOX LO be: 16 Ar F k9eneral). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44"AFF <br />Bathroom 39" AFF <br />Laundry Room 36"AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centedine above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined In UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the Installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFC I protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />L 4::� <br />V4=P`__ <br />DUPLEX CONVENIENCE OUTLET <br />I Z!t!". <br />pip= <br />DUPLEX OUTLET ABOVE COUNTER <br />llf:!, <br />PE�W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />OG&F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />K�-- <br />HALF -SWITCHED DUPLEX OUTLET <br />I Ph <br />r'1:NV <br />SPECIAL PURPOSE OUTLET <br />=E�F <br />DUPLEX OUTLET IN FLOOR <br />I zn!' <br />PJ�E <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />& I <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />@) <br />RECESSED LIGHT FIXTURE <br />+P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />RCH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />PM 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />Millen <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />4. 1L <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />17% <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />< <br />VERIFY METER <br />LOCATION WITH <br />BUILDER =1 H.B. <br />�Av <br />,it 1, <br />'4 <br />G <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-131 <br />SCALE: Y4"=l'-O" <br />C" <br />C-4 <br />CI%A <br />CD <br />M <br />40 <br />to <br />C'4 <br />S <br />C, <br />CA <br />7; <br />E <br />0 <br />Cl> <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. <br />Engineers <br />signature and seal is only for <br />the structural engineering <br />portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />Im. <br />'I g <br />N F, <br />0 <br />tg: <br />N CD <br />co V <br />LLJ Lu <br />M <br />Z M a <br />1; 42 0 <br />0: <br />w <br />W <br />6 to Lu <br />c) Z <br />04 <br />< 0 <br />Z <br />W <br />co <br />or <br />(n <br />V);?: <br />M <br />Q) <br />U <br />0 <br />Ln <br />Ln <br />C� <br />C) 2! <br />M <br />E <br />C) 0 <br />(n <br />�d <br />C> <br />C11> <br />_j <br />E <br />a C' <br />Z <br />E <br />0 <br />Z <br />11 t <br />Z <br />Z <br />(a <br />M <br />0 <br />Z <br />Z <br />Q <br />9 § <br />�z <br />Z <br />M <br />1� <br />C.? <br />05 <br />120 <br />CC <br />L0 <br />V) <br />tM <br />M <br />< <br />0 <br />a- <br />a) <br />F— <br />L0 <br />M <br />LO <br />0 <br />:3 <br />LID <br />Cr <br />ch <br />M <br />tz <br />V) <br />0 <br />U) CY) <br />4- <br />C-4 <br />C:) <br />to <br />CN <br />U. N <br />0) <br />M <br />iz� <br />0 <br />CY) <br />< <br />r- <br />Ir- <br />CD <br />Z <br />cc <br />Z <br />E <br />cc <br />M <br />E <br />0 <br />4i <br />- <br />M <br />C <br />a) <br />< 0 1 <br />_j <br />JOB <br />NO: <br />23-00525 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.