My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36484 Flats St
Zephyrhills
>
Building Department
>
Building Plans
>
36484 Flats St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:04:59 PM
Creation date
2/19/2025 10:51:09 AM
Metadata
Fields
Template:
Building Plans
Street #
36484
Location
Flats St
Contractor
Lennar Homes LLC
Building Plans - Permit #
5972
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
to <br />C14 <br />L0 <br />to <br />04 <br />31 <br />E <br />0 <br />a" <br />C3, <br />CL <br />0 <br />C2 <br />C-4 <br />CD <br />ELECTRICAL SPECIFICATION <br />15OA/200A INDOOR <br />PANEL CENTER <br />NOTES: <br />011#14 to lights & outlets <br />NEMA 1 <br />01 #12 to appliances and GF I <br />ELECTRICAL CONTRACTOR <br />150 AMPI <br />2W AMP <br />10 #10 to WH <br />MUST VERIFY WITH THE <br />10 #8 to Range <br />SPECIFICATIONS FOR THE TYPE <br />10 #8 to HVAC <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />—vETER <br />—T <br />LOCATION PURPOSES. <br />n <br />T /-150=2/0 <br />200=4/0 in 2" Conduit <br />200 <br />:mp <br />150 mp <br />UNDERGROUND <br />Ipisconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />L <br />BONDING <br />GROUNDING WIRE <br />TERMINATION PER <br />Y <br />WITH CODE APPROVED <br />NEC 17, 250-94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES Typical 150-200 Amp Electrical Riser DiagraM REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />I. Electrical outlet heights as measured from finsned floor to nter line or the box to be: 16 Ar r kgeneral). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44"AFF <br />Bathroom 39" AFF <br />Laundry Room 36"AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44"AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done In strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the Installation <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits In all dwelling units per NFPA 7G- 17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The Width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed In <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FEFW.P. <br />WEATHERPROOF DUPLEX OUTLET <br />I /-N.. <br />ftt.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />1. /1-% <br />Fqw= <br />HALF -SWITCHED DUPLEX OUTLET <br />Lph <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />II <br />YO <br />THREE-WAY SWITCH <br />?4 <br />FOUR -WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />@) <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />F51 <br />CHIMES (OPTIONAL) <br />�0 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNM <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />r--- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />SWITCH & LIGHI <br />IN ATTIC SPACE <br />L- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - <br />BEDROOM 6 <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />W.I.0 <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />IRE <br />LIGHT PRE-W <br />BEDROOM 5 <br />TO <br />0 <br />C.M./S.D. <br />LOFT <br />2 <br />ROUGH -IN FOR <br />OPT.CLG.FAN/ <br />LIGHT PRE -WIRE <br />Pt\ <br />/ <br />C M <br />� q <br />'Ww W_ <br />Q'111 <br />/ ;1 S"I <br />1,07" <br />oe <br />'1 /9 <br />6A' ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE-WIR <br />BEDROOM 4 <br />(9 <br />— — — — — — — — — — - 7 — — — <br />L <br />qp <br />ROUGH -IN FOR <br />OPT.CLG.FAN/ <br />LIGHT PRE -WIRE <br />7Uo <br />BEDROOM 3 <br />SECOND FLOOR ELECTRICAL PLAN - ELEV-131 <br />SCALE: Y4"=l'-O" <br />cc <br />:5 c=� <br />r- C= <br />CC <br />Cc <br />C, <br />i3: <br />C"> <br />CD <br />To itie best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is <br />only for <br />the structural engineering portions of the dr&Mrvg pages bearing <br />Engineer's signature and seal. <br />W <br />E <br />8 <br />0 <br />':3 <br />r-- 'L <br />CIJ 0 <br />_j <br />LL U. 'L <br />uj <br />S2 <br />Z <br />M C'l <br />W <br />Z <br />IL <br />Z <br />a <br />C*1 < 0 <br />Z <br />(n <br />CD <br />Z <br />0- <br />V) <br />_ C� <br />0 <br />(1) <br />4—J <br />c,, <br />LU <br />0 <br />Uj <br />V) <br />s <br />l_ W <br />d) <br />< 0 <br />IN 0) <br />Zi <br />_j <br />LL_ <br />E <br />F5 <br />0 <br />E <br />no <br />< <br />Z <br />t0 <br />0 <br />C" C <br />Z <br />S <br />�z <br />Zo <br />02 <br />W <br />21 <br />0 ZW <br />IX <br />< <br />LO <br />0 <br />a- <br />L0 <br />co LO <br />=1 <br />0 <br />LO <br />cy. <br />Cn <br />Cal <br />U') <br />0 <br />c) <br />0) <br />co 04 <br />LL 0 <br />C:) <br />04 <br />M <br />;& <br />U) <br />cle) <br />I.. <br />E <br />LO <br />0 <br />M <br />Z <br />0 <br />E C) <br />2 <br />C <br />.T <br />E ;.; <br />0 0 <br />a 4) <br />'a <br />JOB <br />NO: <br />23-00525 <br />SCALE : <br />AS NOTED <br />SHEEr NO. <br />4.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.