Laserfiche WebLink
ELEV AT 8'• <br />T.O.M. <br />ELEV AT 0'. <br />1 ST FLOOF <br />SHINGLE R( <br />ELEV AT 8'-0" <br />T.O.M. <br />5/8" STUCCI <br />OVER CMU <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />ELEV AT 8'-0" _ <br />T.O.M. <br />1 /4" = 1'-0" <br />REAR ELEVATION B <br />1 /4" = 1 '-0" <br />INGLE ROOF <br />14" THK x 6" <br />UCCO BAND <br />" STUCCO <br />ER CMU <br />75/8" STUCCO <br />OVER CMU <br />00 <br />`D <br />ELEV AT 0'-0" <br />1ST FLOOR FF — L <br />—— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />RIGHT ELEVATION B <br />1 /4" = 1'-011 <br />12 <br />5 -Oet <br />5/8" STUCCO <br />OVER CMU <br />ELEV AT 0'-0" <br />1ST FLOOR FF — — — — — — — — — — — — — — — — — — — — — — — — — <br />LEFT ELEVATION B <br />1 /411 = 1 1 <br />-0" <br />I <br />7 <br />A5 I <br />I <br />� I <br />I <br />I <br />1 <br />W" <br />FINISH <br />!LEVATION <br />SHEATHING <br />FACTURED <br />TRUSS <br />DRIP EDGE <br />INUM WRAP <br />INUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />" OVERHANG DETAIL <br />0 Aa - 1171 <br />12 <br />15 <br />ROOF FINISH PER <br />ELEVATION <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOF TRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />PER ELEVATION <br />ALUMINUM <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />OVERHANG DETAIL <br />fi <br />���M��UMN DETAIL <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />Mill OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />* EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />NOTE: <br />FOAM TO BE USED ONLY WHEN <br />REQUIRED BY COMMUNITY <br />SPECS. IF NOT, DETAIL TO BE <br />BUILT W/ STUCCO <br />m� <br />. k1r,WIMlai <br />5/8" STUCCO <br />FINISH --- <br />2" <br />VARIES <br />N <br />CV <br />ASSUMED GRADE <br />9 ELEVATION DETAIL <br />OCT 18 2022 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approv I <br />he 2020 FBC 7t6 E i <br />e Klahr PX2300 <br />1 1/4" THICK <br />i' <br />N <br />Co <br />.- <br />o <br />00 <br />�I <br />O <br /><: <br />o <br />w <br />0 <br />z <br />Q <br />LO L E <br />W L. C `0'11 0 <br />7 0 CM N `1 <br />N <br />4. <br />HOC �0M <br />M <br />p` 2 S <br />rn <br />V/ O o Q <br />U�� <br />-t <br />'U) <br />U w a� <br />W <br />L � C .m <br />a '0 <br />W <br />dWi vi WOr- <br />F—< _j It< Of z <br />zW 0MOO0�0 <br />Q Q U <br />��L� <br />DO<ZWzmva¢ <br />xLLj Ro�MZ0 <br />00 <br />U) O Z <br />A <Z <br />0_ x JW LL 0OCL <br />U)ZW ZWnQW <br />aLL W �~F- � YQ05 o <br />O F- LL <br />O <br />O <br />Z N <br />OW <br />F— <br />(n O <br />(MO <br />O <br />Q Ln <br />2U)L <br />L_ r" ! <br />�-Wa- M <br />00 <br />Q Q <br />Z U I-- <br />Z <br />J 0 <br />J <br />on <br />I <br />� <br />cue <br />o <br />O <br />o <br />N <br />O <br />NM <br />� <br />' <br />z <br />0 <br />W <br />o <br />o <br />a <br />Lr)N <br />r <br />N <br />' <br />C <br />�^ <br />i <br />Z~ <br />of <br />Qz <br />w <br />O <br />z <br />-1 <br />O <br />W <br />U <br />zz <br />coo <br />wc,- <br />0 <br />Dzj <br />of-o <br />-� <br />Q <br />C) <br />Z <br />F- <br />—a <br />a <br />w <br />Ll <br />= <br />m~LLJ <br />rl <br />z o n <br />. <br />Q <br />Z <br />Zit <br />gLL <br />az <br />. <br />U) <br />Z <br />H2 <br />V <br />.a_I <br />pow <br />m <br />z <br />z <br />z <br />w <br />W <br />J <br />C1 <br />M <br />N <br />O <br />LAST PLOT DATE <br />• <br />April 29, 2022 <br />z <br />J <br />EXTERIOR <br />ELEVATIONS B <br />