A/C <br />DICONNECT <br />WP <br />GFI <br />ELECTRICAL PLAN (ELEVATIONS A & R <br />1 /411 = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />10 #15 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />0. #12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />TYPICAL 150-200 AMP ELECTRICAL <br />RISER DIAGRAM <br />NTS <br />OCT 1 8 ZQZZ <br />\/V\ <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th E ' on <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET ih <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />S r� <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />E)= 110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT IHORIZONTAL <br />110V QUAD OUTLET AT 12" <br />I$-- WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />�1 PUSH-BUTTON DOORBELL <br />-- CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />-- WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />�6 50W MR16 4" LOW VOLTAGE OWNER <br />80 50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />SMOKE DETECTOR <br />cU-18= UNDER CABINET 18" <br />CS-18- SINGLE 18" FLUOR STRIP <br />=U-24- UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />1—,24-_;9 24" VANITY LIGHTING <br />FRF36-RR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />GM CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />�i. ELEC PANEL <br />® VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />ED A/C REGISTER <br />THERMOSTAT <br />in SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />r <br />^, <br />W <br />A' N u7 E <br />i L r� 0 <br />CY) v ti <br />U)cM �! <br />N <br />ff'' <br />V �� m M <br />t$ Z)0 2 <br />° `l 8 c <br />U <br />to <br />O 2 <br />U L" aN C <br />E^ <br />a`. o m <br />WLj � w W. J W O <br />Q <br />�— <br />W <br />V <br />V32-,.03:x< c)0LL0JO <br />j d x 2 LL LL 0 Z O O, <br />~ <br />U <br />I— <br />ptn�O�00Zz <br />cwWwZOWnx <br />WXQpp� <br />�pWQ-ZZO <br />QW¢ <br />iZnain <br />aO <br />gLL OW � gWo <br />OW <br />oFQLL <br />Q Q <br />LL 0 <br />O <br />Z N <br />OW <br />U 5 ti <br />O <br />Q M <br />Q w M � <br />w �I <br />z <br />Ln <br />Ix CL M <br />2 n' o <br />F- <br />Z U <br />Z <br />W <br />WO <br />� <br />O <br />Mj <br />d' <br />CM <br />O <br />O <br />r <br />N <br />N <br />0 <br />N <br />O <br />r <br />N <br />� <br />O <br />C) <br />0 <br />0 <br />wo <br />r <br />0 <br />N <br />0 <br />M <br />; <br />i <br />i <br />1 <br />co <br />cr <br />'/1 <br />Z~ <br />�/, <br />Q Z <br />w <br />O <br />W <br />c O O <br />I--° <br />O <br />U <br />UV� <br />0 <br />O or¢ <br />Z <br />L0 <br />= <br />wWQ <br />H <br />pp <br />W <br />T"I <br />Z o 0 <br />W <br />a <br />§F-::) <br />. . <br />N <br />0 <br />ZWO <br />r- <br />Z <br />U <br />wW <br />g Z" <br />Zz <br />J <br />pV <br />o(L <br />W <br />z <br />A6 <br />z <br />W <br />W <br />J <br />(D <br />M <br />O <br />LAST PLOT DATE <br />April 29, 2022 <br />z <br />0 <br />J <br />ELECTRICAL PLAN <br />