My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6382 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6382 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:38:13 PM
Creation date
2/19/2025 10:59:20 AM
Metadata
Fields
Template:
Building Plans
Street #
6382
Location
Cobble Bliss St
Contractor
Lennar Homes LLC
Building Plans - Permit #
21422
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JREATHER <br />ESISITIVE <br />RRIER <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHING <br />`% „"' <br />3/4"-l" BEAD OF CONSTR. <br />BY LAPPING DOWN <br />ADHESIVE TO BE APPLIED UNDER <br />OVER RIM JOIST AND UP <br />'' _ <br />THRESHOLD OF DOOR AND RETURN <br />WALL BY 61N. <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />-- <br />.....:'. <br />�"`':'-- - <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />o<:;:;;_ <br />,.:.....:...-.:,;::a::''v.......,:::.• <br />'s"`.:re.., `"•,. <br />SUBFLOOR <br />(SEE DETAIL WP07) :;. <br />..::'' <br />...,,• <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />WEATHER <br />�E BARRIER & EXTERIOR SHEATHING <br />tARILY SECURE 3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING VIA' <br />EXTERIOR <br />SHEATHING <br />WEATHER <br />RESISITIVE <br />BARRIER <br />ED FLASHING <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive <br />barrier above header to allow for flashing <br />Installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head 2 <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW Fwpoi <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />r v�annvv r T.r+an nvu <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />NOT USED <br />SELF -ADHERED FLASHING <br />M <br />0 O <br />O <br />WP07 <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />Q <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />NOT USED <br />RIM JOIST <br />2 <br />WP02 <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />2 <br />WP05 <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />2 <br />4 <br />5 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />WP03 <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />NEEDED IN CORNERS RUBBERIZED ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT <br />FLASHING SELF -ADHERED FLASHING ........ <br />SCORED <br />RELEASE PAPER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />110 <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />• : • : INV <br />•. 4 <br />Foundation Walf'• .: <br />FOUNDATION WEEP SCREED <br />NOT USED <br />2 <br />5 <br />4 <br />6 <br />7 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />S <br />WP09 <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW <br />GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. <br />SELF -ADHERED FLASHING <br />PRO <br />DUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2 <br />Detail Instructions <br />Refer to the number marked as in each detail that corresponds to <br />the numbered items in the lis of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water <br />shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on <br />demand, embedded in the adhesive layer) - for ease of <br />installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions <br />and adhere to substrate using a square piece of flashing material <br />(6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of comer may vary, adjust folding of the flashing <br />accordingly to fit tight to comer <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />- 7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. & <br />FRC R703.7.2.1 <br />Maintain <br />Bottom of <br />Weep Screed <br />2" Above Roof <br />Sheathing <br />FLASHING REQUIREMENTS <br />FLASHING AND SEALANTS FOR EXTERIOR WINDOW AND DOOR OPENINGS SHALL COMPLY WITH <br />SECTION R703.4. <br />R703.2 WATER -RESISTIVE BARRIER. ONE LAYER OF NO. 15 ASPHALT FELT, FREE FROM HOLES AND <br />BREAKS, COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED WATER -RESISTIVE <br />BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. SUCH FELT OR <br />MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER THE LOWER <br />LAYER NOT LESS THAN 2 INCHES (51 MM). WHERE JOINTS OCCUR, FELT SHALL BE LAPPED NOT <br />LESS THAN 6 INCHES (152 MM). THE FELT OR OTHER APPROVED MATERIAL SHALL BE CONTINUOUS <br />TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING APPENDAGES IN A <br />MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL ENVELOPE AS DESCRIBED IN <br />SECTION R703.1. THE WATER -RESISTIVE BARRIER IS NOT REQUIRED FOR DETACHED ACCESSORY <br />BUILDINGS. <br />R703.4 FLASHING. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION IN A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF -ADHERED <br />MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION <br />PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT <br />COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT <br />EXPANSION AND CONTRACTION, ASTM C1281, AAMA 812, OR OTHER APPROVED STANDARD AS <br />APPROPRIATE FOR THE TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN <br />EXTERIOR WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH. APPROVED CORROSION RESISTANT FLASHINGS SHALL BE <br />INSTALLED AT THE FOLLOWING LOCATIONS: <br />1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE <br />WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 FOR SUBSEQUENT DRAINAGE. <br />MECHANICALLY ATTACHED FLEXIBLE FLASHINGS SHALL COMPLY WITH AAMA 712. FLASHING AT <br />EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR <br />MORE OF THE FOLLOWING: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING INSTRUCTIONS, OR <br />FOR APPLICATIONS NOT ADDRESSED IN THE FENESTRATION MANUFACTURER'S <br />INSTRUCTIONS, IN ACCORDANCE WITH THE FLASHING MANUFACTURER'S INSTRUCTIONS. <br />WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PAN FLASHING SHALL BE <br />INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL <br />BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE <br />EXTERIOR WALL FINISH OR TO THE WATER RESISTIVE BARRIER FOR SUBSEQUENT <br />DRAINAGE. OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OR <br />PROTECTION AT THE HEAD AND SIDES. <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN <br />PROFESSIONAL. <br />1.31N ACCORDANCE WITH OTHER APPROVED METHODS. <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/ AAMA 200, FMANVDMA 250, FMA/AAMA/ WDMA 300 <br />OR FMA/AAMANVDMA 400. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR <br />STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. & <br />FRC R703.7.2.1 <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />DAN SC O <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.donscoengineedng.com <br />CA 25948 <br />� <br />o <br />S <br />z� <br />14 <br />Z�r\ <br />0 <br />Z <br />a en <br />J'+ <br />. <br />g�g <br />Q ^ <br />�- <br />Z <br />UX <br />5�P� <br />W <br />� � <br />O <br />Mill! <br />U <br />L <br />ITJ <br />LU <br />LU <br />LLl V) <br />J <br />Q m <br />V) LLI <br />Q O o° <br />ca <br />Q O <br />w <br />Z U <br />7- <br />7- <br />00 <br />O � <br />CL <br />GO <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd = 108MPH), 3 SEC. GUST, <br />EXPOSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT = 30.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OF THIS DRAWING ONLY. <br />(02019 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />0 019 - THESE DRAWINGS AND DESIGNS ARE THE <br />JOINT PROPERTY OF DANSCO ENGINEERING, LLC AND <br />THE CLIENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHIBITED. <br />REVISION: <br />DATE <br />DESCRIPTION <br />UPDATED CONNECTION <br />06.08.18 <br />1.01 CROSS-REFERENCE TABLE <br />AND STAIR STRAP <br />01.09.19 <br />1.02 ROOF UNDERLAYMENT REV. <br />02 11 19 <br />1 03 UPDATED CONNECTION <br />CROSS-REFERENCE TABLE <br />VERSION NO. -I / 02.11.19 <br />44 <br />N <br />try <br />0 <br />Q O <br />oe O <br />LU S< <br />m J <br />z O <br />J 111 <br />Q Ce = U <br />W C� � >- 3: <br />CA <br />QN <br />ad =N vJiNO <br />LU _� }OD <br />W >- <br />W <br />Z Q LLl = LLi w <br />5 a, <br />W E E <br />SHEET TITLE: <br />WATERPROOFING DETAILS <br />SHEET INFORMATION: <br />JOB NO.: 390441 <br />DATE ISSUED: 04.04.19 <br />DRAWN BY: LF <br />REVIEWED BY: TH <br />W P <br />O <br />OD <br />O <br />I <br />N <br />IOU <br />LO <br />
The URL can be used to link to this page
Your browser does not support the video tag.