Laserfiche WebLink
I I <br />I I <br />I 1 <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />NOTE: BORATE/ SENTRA CON SYSTEM APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. <br />1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE <br />OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. <br />2) PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED <br />PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. <br />ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS <br />AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE (CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL <br />CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE <br />NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO <br />VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION, FOR EXAMPLE, ACQ-C, <br />ACQ-D, CBA-A, OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. <br />REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS <br />�RE: FBRC R308.4) <br />R308.3 HUMAN I PACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS <br />SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR, <br />PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY II AS INDICATED IN TABLE R308.3.1 <br />EXCEPTIONS: <br />1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY <br />WITH ANSI Z97.1-14 <br />2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 <br />R308.4 HAZARDOUS LOCATIONS. <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: <br />1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. <br />2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD <br />CLOSET DOOR ASSEMBLIES. <br />3. GLAZING IN STORM DOORS. <br />4. GLAZING IN ALL UNFRAMED SWINGING DOORS. <br />5. GLAZING IN DOORS AND ENCLOSURES FOR <br />0 0 HOT TUBS WHIRLPOOL SAUNAS, R AT S, S S, STEAM ROOMS, BATHTUBS, AND <br />SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM <br />EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524MM) MEASURED VERTICALLY ABOVE ANY <br />STANDING OR WALKING SURFACE. <br />6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST <br />VERTICAL EDGE IS WITHIN A 24-INCH 610MM ( )ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE <br />IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. <br />7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS <br />5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: <br />7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 M2). <br />7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR. <br />7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. <br />7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE <br />GLAZING. <br />8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE <br />STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. <br />9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS <br />WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND <br />WITHIN 60 INCHES (1524 MM ) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND <br />ALL PANES IN MULTIPLE GLAZING. <br />10. GLAZING ADJACENT TO STAIRWAY N S, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A <br />WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE <br />PLANE OF THE ADJACENT WALKING SURFACE. <br />11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A <br />STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) <br />ABOVE THE NOSE OF THE TREAD. <br />EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS <br />LOCATIONS: <br />1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. <br />2. DECORATIVE GLASS IN ITEMS 1.6 OR 7. <br />3. GLAZING IN SECTION R308.4, ITEM 6, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER <br />BETWEEN THE DOOR AND THE GLAZING. <br />4. GLAZING IN SECTION R 308.4.2, ITEM 3, IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED <br />POSITION OR WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS <br />IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 2. <br />5. GLAZING IN SECTION R308.4.3, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE <br />GLAZING 36 INCHES ± 2 INCHES (914 ± MM 51 MM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF <br />WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS <br />AND BE A MINIMUM OF 1 % INCHES (38 MM) IN HEIGHT. <br />6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4, <br />ITEM 7, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING <br />SURFACES, OR OTHER HORIZONTAL [WITHIN 45 DEGREES (0.79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE <br />GLASS EXTERIOR. <br />7. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION <br />133082. <br />8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS <br />BACKING SUPPORT. <br />9. SAFETY GLAZING IN SECTION R308.4, IS NOT REQUIRED WHERE: <br />9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING <br />BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF SECTION 1014 OF THE FLORIDA BUILDING <br />CODE, BUILDING; AND <br />9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. <br />GENERAL STRUCTURAL NOTES: <br />1. CODES & REFERENCES: <br />1.1. FLORIDA BUILDING CODE, RESIDENTIAL 6th EDITION. <br />1.2. AMERICAN CONCRETE INSTITUTE OF STRUCTURAL CONCRETE (ACI 318). <br />1.3. AMERICAN CONCRETE INSTITUTE OF MASONRY STRUCTURES (TMS 402/ACI 530/ASCE 5). <br />1.3.1 THE MASONRY SOCIETY DIRECT DESIGN HANDBOOK FOR MASONRY STRUCTURES (TMS 403). <br />1.4. AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES <br />(ASCE-7). <br />1.5. SPECIFICATION FOR THE DESIGN, FABRICATION & ERECTION OF STRUCTURAL STEEL FOR BUILDINGS LATEST <br />EDITION. <br />1.6. DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES BY THE TRUSS PLATE <br />INSTITUTE (TPI) LATEST EDITION. <br />1.7. NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS) LATEST EDITION. <br />1.8. AMERICAN PLYWOOD ASSOCIATION DESIGN CONSTRUCTION GUIDE. (APA) LATEST EDITION. <br />2. DESIGN CRITERIA: <br />2.1. ROOF LOADING: <br />- DEAD 7 PSF FOR SHINGLE OR METAL 20 PSF FOR TILE <br />2.2. FLOOR LOADING: <br />LIVE 40 PSF <br />DEAD 15 PSF MIN. (SEE NOTE 2.4) <br />2.3. RESIDENTIAL BALCONY LOADING: <br />LIVE 40 PSF <br />DEAD 15 PSF <br />2.4. FINISH MATERIAL DEAD LOAD NOTES: <br />2.4.1. FINISH FLOORING MATERIALS NOT EXCEEDING 5 PSF HAVE BEEN ANTICIPATED IN THE NUMBERS ABOVE. <br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO DIRECT THE TRUSS MANUFACTURER TO INCREASE THE <br />TCDL OF THE FLOOR TRUSSES WHERE ANTICIPATED FINISH MATERIAL WEIGHTS WILL BE HIGHER. <br />2.4.2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INFORM THE TRUSS MANUFACTURER AND ENGINEER IF <br />ANTICIPATED FINISH MATERIALS OR FIXTURES WILL EXCEED THE STANDARD INDUSTRY LOADS. <br />GENERALLY STANDARD FLOORING IS AS PER 2.4.1, STANDARD CEILING FINISH IS 5/8" OR LESS GYPSUM <br />MATERIAL. NON-STANDARD LOADS WOULD INCLUDE PLASTER OR TILE CEILINGS, LARGE CHANDELIER <br />OR FAUX BEAM POINT LOADS, STONE SOAKER TUBS, MUD SET TILE FLOORING, STONE FLOORING, ETC. <br />2.5. WIND LOADING SEE TABLE FOR CRITERIA. <br />3. SOIL: <br />3.1. MINIMUM ALLOWABLE SOIL PRESSURE IS ASSUMED TO BE 2,000 PSF AS PER TABLE R401.4.1. <br />3.2. THE FOUNDATION SYSTEM FOR THE ATTACHED PROJECT IS DESIGNED FOR A MINIMUM ALLOWABLE SOIL <br />BEARING PRESSURE OF 2000 PSF. <br />3.3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY SOIL CAPACITY & COMPACTION. <br />4. CONCRETE: <br />4.1. OPERATION INSTALLATION & PROCEDURE TO COMPLY WITH ACI STANDARDS. <br />4.2. CONCRETE & MINIMUM COMPRESSIVE STRENGTH OF 2500 psi @ 28 DAYS (U.N.O.). <br />4.3. REINFORCEMENT REBARS ASTM A615 GRADE 60 (U.N.O.). <br />4A WELD WIRE FABRIC (WWF ASTM A185) or FIBER MESH PER ASTM C1116 TYPE III 4.13. USE 0.1% BY VOLUME <br />MINIMUM (1.5 LBS / CU YD). <br />4.5. LAP SPLICES & HOOKS SEE TABLE. <br />5. MASONRY: <br />5.1. MASONRY CONSTRUCTION & MATERIALS SHALL CONFORM TO ALL REQUIREMENTS OF, "SPECIFICATION FOR <br />MASONRY STRUCTURES (ACI 530.1/ASCE 6/TMS 602)," PUBLISHED BY THE MASONRY SOCIETY, BOULDER, <br />COLORADO: THE AMERICAN CONCRETE INSTITUTE, FARMINGTON HILLS, MICHIGAN: & THE AMERICAN <br />SOCIETY OF CIVIL ENGINEERS, RESTON, VIRGINIA: EXCEPT AS MODIFIED BY THE REQUIREMENTS OF THESE <br />CONTRACT DOCUMENTS. <br />5.2. GENERAL SPECIFICATION FOR MASONRY STRUCTURES: <br />5.2.1. TESTING OF FIELD MATERIALS FOR QUALITY CONTROL IS NOT REQUIRED BY ENGINEER FOR THIS <br />PROJECT. <br />5.2.2. COMPRESSIVE STRENGTH REQUIREMENT IS f'm=1500 PSI. <br />5.2.3. DETERMINATION OF COMPRESSIVE STRENGTH IS THE ALLOWABLE STRESS METHOD. <br />5.2.4. UNIT STRENGTH METHOD IS NOT APPLICABLE. <br />5.2.5. QUALITY ASSURANCE IS NOT APPLICABLE. <br />5.2.6. GROUT SHALL COMPLY WITH ASTM C476. GROUT SHALL BE 3000 PSI U.N.O. & HAVE A SLUMP RANGE OF <br />8"-11 ". <br />5.3. PRODUCTS: <br />5.3.1. MORTAR MATERIALS SHALL BE TYPE M OR S GRAY MORTAR. <br />5.3.2. MASONRY UNIT MATERIALS SHALL BE 1900 PSI MIN. CONCRETE MASONRY UNIT. <br />5.3.3. REINFORCEMENT, PRE -STRESSED TENDONS, & METAL ACCESSORIES SHALL BE 60 KSI REBAR (MIN.). <br />5.3.4. WELDED WIRE FABRIC TO BE INSTALLED AS SPECIFIED ON PLAN SET. <br />5.3.5. STAINLESS STEEL IS NOT APPLICABLE. <br />5.3.6. COATING FOR CORROSION PROTECTION IS NOT APPLICABLE. <br />5.3.7. CORROSION PROTECTION FOR TENDONS IS NOT APPLICABLE, <br />5.3.8. PRE -STRESSING ANCHORAGE, COUPLERS, & END BLOCKS ARE NOT APPLICABLE. <br />5.3.9. JOINT FILLERS ARE NOT APPLICABLE. <br />5.3.10. LINTELS TO BE BY CAST-CRETE UNLESS NOTED OTHERWISE. <br />5.4. EXECUTION: <br />5.4.1. PIPES & CONDUITS ARE NOT APPLICABLE. <br />5.4.2. ACCESSORIES ARE NOT APPLICABLE. <br />5.4.3. MASONRY EXPANSION AND CONTROL JOINTS AS INDICATED IN THE PLAN SET ARE RECOMMENDATIONS <br />ONLY, UNLESS CLEARLY DELINEATED AS "REQ'D." <br />5.4.4. WHEN USED, MASONRY CONTROL JOINTS SHOULD BE INSTALLED IN THE LOCATIONS SHOWN ON THE <br />FLOOR PLAN AT A MINIMUM, BUT SHOULD FOLLOW THE PROVISIONS OF TMS 402/ACI 530/ASCE 5. <br />MASONRY CONTROL JOINTS MAY BE INSTALLED IN ACCORDANCE WITH E/S1, HOWEVER, ALTERNATIVE <br />ACCEPTABLE CONTROL JOINT TYPES INCLUDE 'STANDARD VERTICAL - UNKEYED CONTROL JOINT (3/8")', <br />AND'MICHIGAN CONTROL JOINT'. <br />6. WOOD FRAMING: <br />6.1. DIMENSIONED LUMBER SHALL BE DRESSED S4S, & SHALL BEAR THE GRADE STAMP OF THE <br />MANUFACTURER'S ASSOCIATION. <br />6.2. ALL LUMBER SHALL BE SOUND SEASONED & FREE FROM WARP. <br />6.3. FRAMING WALLS & COLUMNS <br />6.3.1. MINIMUM OF 3 PLY 2x STUD S.Y.P. COLUMNS TO BE INSTALLED @ BEAM OR GIRDER TRUSS BEARING <br />LOCATIONS. UNLESS NOTED OTHERWISE. <br />6.3.2. ALL TRUSS BRACING LUMBER SHALL BE S.Y.P. #2 OR BETTER. <br />6.3.3. INTERIOR LOAD BEARING WALL STUDS TO BE SPACED @ 16" O.C. & SHALL BE S.P.F. #2 OR BETTER, U.N.O. <br />6.3.4. TYPICAL AT ALL LOAD BEARING S.P.F. COMPONENTS, #2 GRADE SHALL BE USED FOR 2x4, FOR 2X <br />DEPTHS GREATER THAN 2x4, #2 GRADE OR BETTER MAY BE USED. ALL 4x MATERIAL MAY BE #2 GRADE <br />U.N.O. <br />6.3.5. INTERIOR NON -LOAD BEARING WALLS SHALL BE UTILITY GRADE OR BETTER, AND MAY BE SPF. <br />6.3.6. INSTALL BLOCKING IN ALL WALL STUDS OVER 8'-0 @ MID -HEIGHT, & SHEATHING JOINT. BRACE GABLE <br />END WALLS @ T-0 O.C. MIN. <br />6.3.7. ALL LOAD BEARING WALLS SHALL HAVE S.P.F. DOUBLE TOP AND SINGLE BOTTOM PLATES & SHALL BE <br />FASTENED PER DETAILS HEREIN. INTERIOR BEARING COLUMNS/STUD PACKS NEED NOT PENETRATE <br />TOP AND BOTTOM PLATES AS LONG AS TOP PLATE IS OF A LUMBER GRADE EQUAL TO OR BETTER THAN <br />THE BOTTOM CHORD OF THE TRUSS/JOIST ABOVE. <br />6.4. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED OR NATURAL <br />DURABLE WOOD. <br />6.5. PRESSURE TREATED LUMBER SHALL BE IMPREGNATED WITH A CCA SALT TREATMENT IN ACCORDANCE WITH <br />F.S. 11-W-571 & BARE THE AMERICAN WOOD PRESERVES INSTITUTE EQUALITY MARK LP-2. <br />6.6. ALL SHEATHING TO BE SPAN RATED FOR APPROPRIATE APPLICATION. ALL ROOF SHEATHING TO INSTALLED <br />WITH PLY CLIPS (MAXIMUM 24" O.C.). (SEE PLANS FOR SHEATHING THICKNESS.) FOR ALL SHEATHING <br />ATTACHMENT, SEE TYPICAL NAILING SCHEDULE, INSTALL ALL SHEATHING WITH EDGE GAPS AS REQUIRED BY <br />THE APA. <br />6.6.1. ROOF SHEATHING: SHINGLE OR METAL 7/16" MIN. THICK APA RATED SHEATHING SUPPORTED RTED OVER VER 24" <br />MAX. SPAN. AT TILE USE MIN. 15/32" THICK APA RATED SHEATHING SUPPORTED OVER 24" MAX. SPAN. <br />CONTRACTOR SHALL ADJUST MIN. SHEATHING CRITERIA, IF NECESSARY, TO ACCOMODATE THE TILE <br />MANUFACTURER'S WARRANTY REQUIREMENTS. THE MOST STRINGENT SHALL CONTROL. <br />6.6.2. WALL: 7/16" MIN. THICK SUPPORTED OVER 24" MAX. SPAN. <br />6.6.3. FLOOR: CARPET, VINYL, WOOD, ETC., 3/4" MIN. TONGUE & GROOVE SUPPORTED OVER 24" MAX. SPAN <br />CERAMIC TILE, MARBLE, ETC., SEE MANUFACTURERS RECOMMENDATIONS AND/OR WARRANTY <br />REQUIREMENTS.. <br />6.7 ALL NAILING & BOLTING SHALL COMPLY WITH AMERICAN INSTITUTE OF TIMBER CONSTRUCTION <br />REQUIREMENTS. ALL NAILS EXPOSED TO THE EXTERIOR SHALL BE GALVANIZED. <br />6.8 ALL CONNECTION HARDWARE SHALL BE GALVANIZED & SUPPLIED BY SIMPSON STRONG TIE CO., USP, OR <br />EQUIVALENT. ALL NAIL HOLES SHALL BE FILLED OR AS PRESCRIBED BY THE MANUFACTURER. <br />6.9 BRACING: TEMPORARY BRACING OF THE ROOF SYSTEM SHALL BE INSTALLED PER BCS1 RECOMMENDATIONS <br />& SHALL BE UTILIZED AS THE PERMANENT BRACING FOR THE ROOF SYSTEM (U.N.O.). <br />6.10 ALL WOOD FRAMING SHALL BE IN COMPLIANCE WITH THE LATEST NDS EDITION FOR WOOD CONSTRUCTION. <br />6.11 INTERIOR SHEAR WALL SHALL BE CONSTRUCTED BY ATTACHING 7/16" APA RATED SHEATHING TO ONE SIDE <br />WITH NAILING PATTERN PER'O'/S2, ATTACH TO SLAB WITH 1/2" DIA. x 10" A.B. @ 24" O.C. OR TO WOOD FLOOR <br />SYSTEM WITH (2) SIMPSON SDS25600 @ 24" O.C. MAX. TO FLOOR TRUSSES OR BLOCKING AS APPLICABLE. AT <br />TOP PLATE ABOVE ATTACH WITH SIMPSON HTS16 OR TO BLOCKING ABOVE @ 24" O.C. AS PER DETAIL P/S2. <br />7. MICRO -LAM LUMBER (ALSO LVL, PARALLAM, ETC.) <br />7.1 STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES <br />7.1.1 E=2,000,000 PSI <br />7.1.2 Fb=2950 PSI <br />7.1.3 Ft=1850 PSI <br />7.1.4 Fc--500 PSI (PERP) <br />7.1.5 Fc=2700 PSI (PARALLEL) <br />7.1.6 Fv=285 PSI <br />GENERAL NOTES: <br />PRE-ENGINEERED WOOD PRODUCTS: <br />• ALL PRE-ENGINEERED WOOD PRODUCTS SHALL BE VERIFIED BY TRUSS MANUFACTURER. TRUSS MANUFACTURER <br />HALL HAVE THE AUTHORITY T MAKE SUBSTITUTIONS OR PRODUCTS SPECIFIED ON THE PLANS DUE T S 0 0 SU U S F 0 E N 0 <br />AVAILABILITY OR ECONOMICS. CHANGES SPECIFIED BY THE TRUSS MANUFACTURER SHALL CONTROL. CHANGES <br />MADE AFTER TRUSS ENGINEERING HAS BEEN PROVIDED TO ENGINEER OF RECORD, MUST BE APPROVED BY THE <br />ENGINEER OF RECORD. <br />• ALL PRE-ENGINEERED WOOD PRODUCTS ARE THE RESPONSIBILITY OF THE TRUSS MANUFACTURER. THE TRUSS <br />ENGINEER IS A DELEGATED ENGINEER FOR THIS PROJECT & AS SUCH, IS RESPONSIBLE FOR THE VALIDITY OF THE <br />COMPONENTS PROVIDED. FRAMING LAYOUTS SHOWN MAY BE CHANGED BY THE TRUSS MANUFACTURER. THE <br />DELEGATED ENGINEER IS RESPONSIBLE FOR PROVIDING A FINAL SEALED SET OF ALL CALCULATIONS & LAYOUTS <br />FOR THIS PROJECT TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO MANUFACTURE OF SAID COMPONENTS. <br />ENGINEER OF RECORD HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUFACTURER'S COMPONENTS @ <br />THIS TIME & RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER SUCH INFORMATION HAS BEEN PROVIDED FOR <br />REVIEW. CONTRACTOR, AS PROJECT COORDINATOR, SHALL BE RESPONSIBLE FOR INSURING INFORMATION <br />REQUESTED ABOVE HAS BEEN SUBMITTED TO ENGINEER OF RECORD IN A TIMELY MANNER WHEN AVAILABLE. <br />• ALL PRE-ENGINEERED TRUSSES TO BE DESIGNED USING THE MOST RECENT TPI CRITERIA. TRUSSES TO BE <br />HANDLED & INSTALLED USING MOST RECENT BCSI RECOMMENDATIONS. TEMPORARY & PERMANENT BRACING <br />SHALL BE PER MOST RECENT BCSI RECOMMENDATIONS UNLESS NOTED OTHERWISE, OR MORE STRINGENT CODE <br />REQUIREMENTS APPLY. TRUSS ENGINEER IS RESPONSIBLE FOR INDICATING ALL TRUSS TO TRUSS CONNECTORS. <br />ALL COMPONENTS TO BE DESIGNED FOR BOTH GRAVITY & UPLIFT LOAD CASES, INCLUDING BEAM COMPONENTS. <br />• NOTE: UPON REVIEW, ENGINEER OF RECORD WILL PROVIDE A REVIEW LETTER INDICATING ANY CHANGE IN <br />STRAPPING OR SUPPORT BASED ON THAT REVIEW. CONSTRUCTION COMMENCING PRIOR TO ENGINEER'S REVIEW <br />IS SUBJECT TO MODIFICATION BASED ON REVIEW LETTER. <br />• TRUSS CONNECTIONS SPECIFIED BY THE TRUSS MANUFACTURER SHALL CONTROL. <br />• THE ENGINEERING DETAILS SHOWN HEREIN SHALL CONTROL IF THERE IS A DIFFERENCE OF CONNECTOR <br />SPECIFICATIONS IN ANY OTHER PART OR PORTION OF THE PLAN SET. <br />PRECAST CONCRETE COMPONENTS: <br />• THE USE OF PRE -CAST & PRE -STRESSED CONCRETE COMPONENTS IS ANTICIPATED IN THIS DESIGN, NAMELY <br />LINTELS AND WIND RESISTANT SILLS SHALL BE USED THROUGHOUT UNLESS SPECIFICALLY STATED OTHERWISE. <br />ALL COMPONENTS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. PRE -CAST LINTELS HAVE BEEN <br />REVIEWED & PLACED BASED ON THE DESIGN ALLOWABLE LOAD INFORMATION PROVIDED BY CASTCRETE. USE OF <br />CASTCRETE LINTELS AND SILLS OR A STRUCTURAL EQUIVALENT BY ANOTHER MANUFACTURER IS REQUIRED. <br />MANUFACTURED PRODUCTS: <br />• ALL MANUFACTURED PRODUCTS SUCH AS: ROOFING, WINDOWS, DOORS, ETC. ARE SHOWN HEREIN FOR <br />ILLUSTRATION UR E N <br />• THE INFORMATION SHOWN IS THE RESPONSIBILITY OF THE MANUFACTURER. THE MANUFACTURER IS <br />RESPONSIBLE FOR THE VALIDITY OF THE COMPONENTS PROVIDED. ATTACHMENT INFORMATION GIVEN BY THE <br />MANUFACTURER IS PROVIDED HEREIN. CONTRACTOR, AS PROJECT COORDINATOR, SHALL BE RESPONSIBLE FOR <br />INSURING THAT THE APPROPRIATE PRODUCT/COMPONENT IS USED & THAT IT HAS BEEN INSTALLED PER <br />MANUFACTURER'S SPECIFICATIONS SUCH THAT IT WILL WITHSTAND THE COMPONENTS & CLADDING PRESSURES <br />REQUIRED BY THE SEALED PLANS. <br />of <br />NOTE: ENGINEER OF RECORD HAS NOT REVIEWED THIS INFORMATION FOR APPLICABILITY OR AS A FORM OF <br />PRODUCT APPROVAL OR ENDORSEMENT. <br />FRAMING, DRYWALL & TRIM: <br />• ALL WALLS & KNEE WALLS SURROUNDING STAIRWELLS ARE TO BE FRAMED @ 16" O.C. TO PROTECT FROM <br />FALLING HAZARD. <br />• ALL KNEE WALLS WHICH ALSO ACT AS GUARDRAILS SURROUNDING STAIR, BALCONY, OR VOLUME AREAS SHALL <br />BE ANCHORED SUFFICIENT TO RESIST THE LATERAL AND/OR VERTICAL LOADS REQUIRED BY CODE FOR FALL <br />PROTECTION. THE FOLLOWING SUGGESTED ATTACHMENTS ARE INTENDED TO PROVIDE A BASE GUIDELINE IN <br />THE ABSENCE OF ANY OTHER DIRECTIVE AND SHALL APPLY WHERE AN ALTERNATIVE "SYSTEM" IS NOT BEING <br />USED, OR U.N.O. <br />of AT LOCATIONS WHERE THE FLOOR SYSTEM BELOW THE GUARDRAIL IS PERPENDICULAR, AT 48" O.C. MAX. (1) <br />2X4 STUD WITHIN THE KNEE WALL SHALL PENETRATE THE BOTTOM PLATE OF THE KNEE WALL AND FLOOR <br />SHEATHING AND SHALL "SISTER" ALONGSIDE THE FLOOR TRUSS/JOIST/BEAM AND SHALL NAIL TO THAT <br />FLOOR TRUSS WITH (3) 0.131 X 3-1/2" NAILS AT BOTH THE TOP CHORD AND BOTTOM CHORD, OR IF THE TRUSS <br />HAS A VERTICAL WEB COMPONENT AT THE "SISTERED" LOCATION (6) 0.131 X 3-1/2" NAILS EQUALLY SPACED <br />AND STAGGERED MAY BE USED ALONG THE LENGTH OF THE "SISTERED" STUD INTO THE VERTICAL WEB <br />COMPONENT. •0 <br />AT LOCATIONS WHERE THE FLOOR SYSTEM BELOW THE GUARDRAIL IS PARALLEL TO THE GUARDRAIL, THE <br />BOTTOM PLATE OF THE GUARDRAIL KNEE WALL SHALL BE ATTACHED TO THE PARALLEL FLOOR SUPPORT <br />BELOW WITH (2) ROWS OF SIMPSON SDS25600 SCREWS AT 8" O.C. ALONG THE LENGTH OF THE KNEE WALL. <br />IN ADDITION, THE SIDE OF THE KNEEWALL ADJACENT TO THE OPENING SHALL BE FULLY SHEATHED WITH <br />7/16" OSB OR EQUAL FROM THE TOP PLATE OF THE KNEEWALL TO THE BOTTOM OF THE FLOOR SUPPORT <br />BELOW, NAILED PER THE "WALL" NAILING PATTERN (SHEATHING MAY BE VERTICALLY ORIENTED), BRIDGING <br />THE HINGE POINT. ON THE NON -OPENING SIDE OF THE KNEEWALL, THE KNEE WALL STUDS SHALL ATTACH <br />TO THE BOTTOM PLATE WITH SIMPSON SP1 CONNECTORS AT EACH STUD. <br />•• IF A GUARDRAIL/KNEE WALL TERMINATES AT A FULL HEIGHT WALL, A CRIPPLE STUD SHALL BE SISTERED TO <br />THE FULL HEIGHT STUD AND SHALL BE NAILED WITH (6) 0.131 X 3-1/2" NAILS STAGGERED AND EQUALLY <br />SPACED, AND THE DOUBLE TOP PLATE OF THE KNEE WALL SHALL BE NAILED TO THE FULL HEIGHT STUD <br />WITH (4) 0.131 X 3-1/2" TOE NAILS. THIS ATTACHMENT SHALL ALSO APPLY AT ALL CHANGES OF DIRECTION AT <br />E KNEE WALL. <br />•• AIL KNEEWAL S THAT ALSO FORM GUARDRAILS SHALL HAVE DOUBLE 2X TOP PLATES, STRUCTURALLY <br />CONTINUOUS. <br />•• EACH <br />X TUD2 WITHITOENAILOR EE AL.L SHALL BE ATTACHED TO BOTH THE TOP AND BOTTOM PLATES WITH (3) <br />•• UNDERSTANDING THAT THESE ATTACHMENTS AND WALL CONFIGURATIONS MAY VARY GREATLY AND THAT <br />NUMEROUS "SYSTEMS" ARE AVAILABLE IN THE MARKETPLACE TO PROVIDE SUFFICIENT RESISTIVITY FOR <br />THESE LOADS, IT IS NOT THE INTENT OF THIS PROVISION TO LIMIT THE USE OF ALTERNATE ATTACHMENTS. <br />• BRICK/STONE SHALL BE SELF SUPPORTING, MASON SHALL PROVIDE ANGLE SUPPORT AT OPENINGS SUCH THAT <br />IT SPANS THE OPENING & DOES NOT ADD WEIGHT TO HEADERS. HEADERS PROVIDE LATERAL SUPPORT ONLY. <br />• AT MASONRY, USE 6"X6"X3/8" STEEL ANGLE W/ 1/2" DIA. X 5" SIMPSON TITEN HD ANCHORS @ 24" O.C. W/ 4" LAP <br />ONTO BRICK SUPPORT ON EITHER SIDE MINIMUM, ANGLE SIZE PER B.I.A. & F.B.C. CRITERIA, OR BY OTHERS. <br />• AT FRAME, USE 5"X5"X3/8" STEEL ANGLE W/ 3/8" DIA. X 4" LAG SCREWS @ 12" O.C. W/ 4" LAP ONTO BRICK SUPPORT <br />ON EITHER SIDE MINIMUM. ANGLE SIZE PER B.I.A. & F.B.C. CRITERIA, OR BY OTHERS. <br />• BRICK/STONE TIES, ANGLES SUPPORTS, AESTHETIC FINISHES SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />TMS 402/ACI 530/ASCE 5 AS APPLICABLE. <br />• VORTEX ENGINEERING, LLC. IS NOT RESPONSIBLE FOR BRICK/STONE INSTALLATION INFORMATION, AS <br />BRICK/STONE DESIGN IS BY OTHERS. <br />• SECOND FLOOR AREAS NOT IN ALIGNMENT WITH FIRST FLOOR AREAS HAVE BEEN ASSUMED TO REQUIRE <br />BRICK/STONE BEARING ON TRUSS SYSTEM BELOW. TRUSS MANUFACTURER TO INCLUDE ADDITIONAL DEAD LOAD <br />FOR SUCH AREAS, & LIMIT DEFLECTION TO U600 IN THESE AREAS FOR PURPOSES OF BRICK SUPPORT. <br />FOUNDATIONS HAVE BEEN SIZED FOR THE ADDITIONAL DEAD LOAD DUE TO BRICK/STONE. <br />• BRICK/STONE & ITS SUPPORT EXCEPT AS NOTED IS BY OTHERS. NOTED CRITERIA IS A MINIMUM STANDARD. TIES, <br />FLASHINGS, WEEPS, CONTROL JOINTS, & ALL OTHER BRICK/STONE CRITERIA IS BY OTHERS. <br />• THE NOTES ABOVE PERTAIN TO CLAY BRICK MASONRY & NATURAL STONE. SIMULATED PRODUCTS & VENEERS <br />SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS & THEIR FLORIDA PRODUCT APPROVAL OR <br />MIAMI/DADE NOA. <br />NOTE: <br />IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. FLORIDA <br />DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY <br />DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' SHOP DRAWINGS, CONTRACTORS' <br />BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF <br />FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. <br />NOTE: <br />GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" <br />,„ <br />1 DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1 "DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND <br />EDGES OF WALLBAORD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS <br />(EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW / NAIL DISTANCEFROM <br />EDGE SHALL BE 8". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED <br />ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE <br />COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. <br />DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. <br />NOTE: <br />ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE <br />DRAWINGS AND CAN NOT BE REVISED. <br />SPECIFICATION FOR ANCHOR BOLTS <br />(THE FOLLOWING SHALL APPLY U.N.O.) <br />• ALL 1/2" DIA. A.B. INTO THE TOP OF A MASONRY KO BLOCK COURSE SHALL HAVE A MINIMUM <br />EMBEDMENT OF 5". <br />• ALL 1/2" DIA. OR 5/8" DIA. A.B. INTO THE SIDE OF FILLED MASONRY SHALL HAVE A MINIMUM EMBEDMENT <br />OF 5". <br />• ALL 1/2" DIA. A.B, INTO THE TOP OF A GROUTED MASONRY STEMWALL SHALL HAVE A MINIMUM <br />EMBEDMENT OF 6". <br />• ALL 1/2" DIA. A.B. INTO THE TOP OF CONCRETE THICKENED SLABS SHALL HAVE A MINIMUM EMBEDMENT <br />OF 7". <br />• ANY DIFFERING NOTATIONS FOR EMBEDMENT MADE ON THE PLAN SET SHALL CONTROL. <br />• THESE NOTES ARE SPECIFICALLY FOR ANCHOR BOLTS WITH A 90 DEGREE HOOK, THEY DO NOT APPLY <br />TO ANY OTHER ANCHORAGE DEVICE. SPECIFICATIONS FOR THOSE DEVICES MUST ACCOMPANY THE <br />NOTATION TO USE SAME. <br />ULTIMATE WIND SPEED (Volt) 139.,B MPH <br />NOMINAL WIND SPEED (Valt) 106 MPH <br />RISK CATEGORY II <br />WIND EXPOSURE C <br />INT. PRESSURE COEFF. +/- 0.18 ENCLOSED <br />MAX. MEAN ROOF HEIGHT 20.0' (ONE STORY) <br />COMPONENTS AND CLADDING INTERIOR ZONE (ULTIMATE) <br />COMPONENTS AND CLADDING END/EDGE ZONE (ULTIMATE) <br />ROOF -9 10 SQFT <br />+ 26.1 / -453 PSF <br />ROOF -8 10 SOFT <br />+ 26.1 /-10ro.IPSF <br />g 20 SQFT <br />+ 24.2 / -43.4 PSF <br />-9 20 SQFT <br />+ 24.2 / -99.4 PSF <br />a 50 SQFT <br />+ 203 / -42.2 PSF <br />-S 50 SQFT <br />+ 203 / -90.6 PSF <br />a 100 SQFT <br />+ 10.4 / -415 PSF <br />-9 100 SQFT <br />+ 10.4 / -83l PSF <br />W <br />WALL ® -a Ira SQFT <br />+ 453 / -49.1 PSF <br />WALL © -9 10 SQFT <br />+ 453 / -60.6 PSF <br />]-_ <br />© a 20 SQFT <br />+ 42.2 / -4-1.2 PSF <br />0 6 20 SQFT <br />+ 42.2 / -56.6 PSF <br />50 SQFT <br />+ 40.E / -43.4 PSF <br />(:F:) a 50 SQFT <br />+ 40.7 / -51.8 PSF <br />a 100 SQFT <br />+ 38.4 / -41.5 PSF <br />'a 100 SQFT <br />+ 35.4 / -50.3 PSF <br />500 SQFT <br />+ 33.8 / -316 PSF <br />-9 500 SQFT <br />+ 33.6 / -31.6 PSF <br />I- <br />A <br />GARAGE DOOR 8' WIDTH <br />+ 40.4 / -43.1 PSF <br />GARAGE DOOR 6' WIDTH <br />+ 40A / -45.0 PSF <br />n <br />O 10' WIDTH <br />+ 39.6 / -42.6 PSF <br />O 10' WIDTH <br />+ 39.8 / -44B PSF <br />12' WIDTH <br />+ 39.1 / -42.1 PSF <br />12' WIDTH <br />+ 39.1 / -44Z PSF <br />16'+ WIDTH <br />+ 38.2 / -413 PSF <br />16'+ WIDTH <br />+ 36.2 / -43.2 PSF <br />CHART IS IN "ULTIMATE" PRESSURES. <br />CHART IS IN "ULTIMATE" PRESSURES. <br />CHART MAY BE INTERPOLATED <br />CHART MAY BE INTERPOLATED <br />GARAGE DOOR PRESSURES ASSUME NO END ZONE <br />GARAGE DOOR PRESSURES ASSUME T MAX IN END ZONE <br />_j <br />COMPONENTS AND CLADDING INTERIOR ZONE (ALLOWABLE) <br />COMPONENTS AND CLADDING END/EDGE ZONE (ALLOWABLE) <br />ROOF a 10 SQFT <br />+ 15.E / -272 PSF <br />ROOF a 10 SQFT <br />+ 15.7- / -64.0 PSF <br />Q 20 SQFT <br />+ 14.5 / -26.0 PSF <br />a 20 SQFT <br />+ 14.5 / -59.6 PSF <br />T_ <br />9 50 SQFT <br />+ 12.2 / -253 PSF <br />0 50 SQFT <br />+ 12.2 / -54.4 PSF <br />O <br />a 100 SQFT <br />+ 11.0 / -24.9 PSF <br />tv 100 SQFT <br />+ 11.0 / -50.2 PSF <br />WALL ® 6 10 SQFT <br />+ 27.2 / -29.5 PSF <br />WALL © a 10 SQFT <br />+ 2-12 / -36.4 PSF <br />w <br />© a 20 SQFT <br />+ 253 / -253 PSF <br />� 6 20 SQFT <br />+ 25.3 / -34.1 PSF <br />-1 <br />(!�:) 6 50 SQFT <br />+ 24.4 / -26.0 PSF <br />0 G 50 5QFT <br />+ 24.4 / -31.1 PSF <br />uj <br />a 100 SQFT <br />+ 23.0 / -24.9 PSF <br />-9 100 SQFT <br />+ 23.0 / -30.2 PSF <br />6 500 SQFT <br />+ 20.3 / -22.6 PSF <br />a 500 SQFT <br />+ 20.3 / -22.6 PSF <br />GARAGE DOOR 8' WIDTH <br />+ 24.2 / -25.9 PSF <br />GARAGE DOOR 8' WIDTH <br />+ 24.2 / -21.0 PSF <br />® <br />O 10' WIDTH <br />+ 23.9 / -25.ro PSF <br />O 10' WIDTH <br />+ 23.9 / -2rol PSF <br />A <br />12' WIDTH <br />+ 23.5 / -253 PSF <br />12' WIDTH <br />+ 23.5 / -26.4 PSF <br />-A <br />16'+ WIDTH <br />+ 22.9 / -24.8 PSF <br />16'+ WIDTH <br />+ 22.9 / -25.9 PSF <br />I <br />CHART IS IN "ALLOWABLE/NOMINAL" PRESSURES. <br />CHART IS IN "ALLOWABLE/NOMINAL" PRESSURES. <br />CHART MAY BE INTERPOLATED <br />CHART MAY BE INTERPOLATED <br />GARAGE DOOR PRESSURES ASSUME NO END ZONE IIIGARAGE <br />DOOR PRESSURES ASSUME T MAX IN END ZONE <br />BLOCKING DEFINED <br />(THE .N.O.) <br />THROUGHOUT THIS PLAN THE TERM BLOCKING IS USED AS A GENERIC TERM. THIS NOTE SEEKS TO CLARIFY PROPER BLOCKING TECHNIQUE:' <br />• BLOCKING SHALL BE THE SAME SPECIES AND LUMBER GRADE AS INDICATED IN GENERAL STRUCTURAL NOTE 6.3.4. <br />• BLOCKING SHALL BE ATTACHED WITH (3) 0.131X3-1/2" TOENAILS INTO THE STUDS AT EITHER END, U.N.O. <br />• BLOCKING IN A WALL CAVITY IS TO BE INSTALLED IN THE SAME ORIENTATION AS THE BOTTOM PLATE (HORIZONTAL AND FLATWISE), AND SHALL <br />EXTEND TO FILL THE CAVITY FORMED BY THE STUDS. U.N.O. <br />• BLOCKING WITHIN A FLOOR TRUSS WEB SPACE IS TO BE ORIENTED THE SAME AS THE END VERTICAL OF THE TRUSS (ON END), AND SHALL EXTEND <br />FROM TOP TO BOTTOM CHORD, OR IF INTERRUPTED BY DIAGONAL WEB COMPONENTS, IT SHALL EXTEND FROM THE TOP CHORD, TO THE WEB <br />MEMBER, AND A SECOND PIECE SHALL BE INSTALLED FROM THE WEB MEMBER TO BOTTOM CHORD, ALIGNED VERTICALLY, U.N.O. <br />• BLOCKING WITHIN A ROOF TRUSS WEB SPACE SHALL BE ORIENTED PERPENDICULAR TO THE BOTTOM CHORD, AND FLATWISE WITHIN THE PLANE <br />OF THE TRUSS WEB ON END. BLOCKING WITHIN THE TRUSS SHALL EXTEND FROM BOTTOM CHORD TO TOP CHORD OR IF INTERRUPTED BY <br />WEB MEMBER AND A SECOND PIECE SHALL BE INSTALLED FROM THE <br />DIAGONAL WEB COMPONENTS, IT SHALL EXTEND FROM THE TOP CHORD, TO W <br />WEB MEMBER TO BOTTOM CHORD, ALIGNED VERTICALLY, AS NECESSARY TO FACILITATE THE ITEM FOR WHICH BLOCKING IS NEEDED, U.N.O. <br />• BLOCKING BELLOW WITHIN DTO FILL THEE AREA TOADSPACEKEN UP BY TRUSS WORKI.E. THE VOID .)) FOR TRANSFERRINGACE BETWEEN THE OTTOM PLATE UPPER POINT OF AN LOA S (I.E. STUD PACKS) TOALL TO THE LOWER OMPO ENSONRY OR FRAME WALL <br />SHALL BE INSTALLED IN THE SAME ORIENTATION, OF THE SAME WOOD TYPE AND GRADE, AND OF THE SAME NUMBER OF PLIES, AS THE STUD PACK <br />ABOVE. <br />• BLOCKING INSTALLED BETWEEN ADJACENT TRUSSES SHALL BE PERPENDICULAR TO THE TRUSS CHORD BEING BLOCKED, AND SHALL BE ORIENTE <br />ON EDGE. EXCEPTION: AT HIP AND VALLEY LOCATIONS BLOCKING WHICH SUPPORTS THE SHEATHING JOINTS MUST FOLLOW THE HIP OR VALLEY <br />AND SHALL THEREFORE NOT BE PERPENDICULAR TO THE TRUSS CHORD BEING BLOCKED. U.N.O. <br />• IN GENERAL BLOCKING INSTALLED AS PER THE CRITERIA ABOVE IS INTENDED FOR STRAPPING, BRACING, AND SUPPORT, U.N.O. <br />SPECIFICATION FOR LANDINGS & STAIR CONSTRUCTION <br />(THE FOLLOWING SHALL APPLY U.N.O.) <br />• ALL STRINGERS TO BE 2-2X12 #2 SYP. <br />• ALL STRINGERS TO ATTACH AT LANDINGS & UPPER FLOOR LEVELS WITH SIMPSON LSC HANGER. <br />• <br />STRINGERS RUNNING & PARALLEL TO SUPPORTED BY A WALL SHALL BE ATTACHED: <br />R <br />•• @ MASONRY/CONC. WITH 4" DIA X 3" TAPCONS AT 8" O.C. STAGGERED ALONG THE LENGTH OF THE STRINGER (USE PT AT MAS./CONC.). <br />of @ WOOD WITH (4) 0.131 X 32' NAILS AT EA. STUD MIN. (16" O.C. MAX) <br />IF STRINGERS ARE SUPPORTED IN THIS WAY, LSU <br />GERS ARE <br />• •• ALL STRINGERS SPRINGING FROM A FLAT SURFACE SHALL TERMINATE OREQUIRED TERM NATE AT A 2X4 FOOT (TO BE PT AT CONC.). ATTACH FOOT TO FLOOR: <br />•• @ CONC. W/ 4' DIA. X 3" TAPCONS @ 12" O.C. <br />•• @ WOOD ATTACH W/ 0.131 X 31" NAILS AT 8" O.C. TO TRUSS/JOIST/ OR BLOCKING BELOW. <br />•• ATTACH STRINGER TO FOOT WITH (2) 0.131X32' TOENAILS EA. <br />• •• LANDINGS SHALL BE BUILT AS FOLLOWS: <br />JOISTS TO BE 2X8 #2 SYP, MIN. @ 16" O.C. <br />•• IF LANDING INCLUDES STRINGER SUPPORT IN A BEAM CONFIGURATION, BEAM SHALL BE (2) 2X12 #2 SYP WITH 2-2X4 SUPPORT STUDS AT <br />EACH END. <br />•• IF LANDING IS SUPPORTED BY A KNEEWALL, PROVIDE A 2X8 END JOIST WITH (3) 0.131X32' R.S. END NAILS AT EACH LANDING JOIST, & (2) 0.131 <br />X 32' TOE NAILS FROM EACH JOIST TO KNEEWALL TOP PLATE. <br />•• LEDGERS TO BE 2X8 WITH: <br />••• (4) 0.131X32' NAILS AT EACH PASSING STUD AT WOOD ATTACHMENT 16" O.C. MAX. <br />••• "X 3" TAPCONS @ 8" O.C. STAGGERED @ MASONRY/CONCRETE ATTACHMENT. <br />•• <br />ATTACH JOISTS TO LEDGERS OR BEAMS WITH SIMPSON LUS26 HANGERS OREQUAL. <br />• THE SPECIFICATION LISTED ABOVE OR MINIMUM SPECS. SUBSTITUTIONS OF EQUAL OR BETTER CAPACITY ARE ACCEPTABLE. <br />• GUARDRAILS & HANDRAILS ARE BY OTHERS, INCLUDING THEIR ATTACHMENTS. ALL RAIL SYSTEMS MUST MEET OR EXCEED THE REQUIREMENTS <br />OF FBC TABLE R301.5 & SECTION R312. <br />SPECIFICATION FOR BUCK ATTACHMENT <br />• IF lx - ATTACH WINDOW THROUGH BUCK TO <br />MASONRY/WOOD FRAMING. IF 2x - ATTACH TO 2x BUCK. <br />• IF 2x - ATTACH TO MASONRY w/ 1/4" x 3" MASONRY <br />ANCHORS @ 12" O.C. w/ MAX. 6" FROM END OF BUCK <br />(TYP. ALL 2x WINDOW BUCK ATTACHMENT.) <br />LIMITATIONS <br />(THE FOLLUWINCj SHALL APPLY U.N.O.) <br />• VORTEX ENGINEERING, LLC. HAS CHECKED THE <br />ATTACHED DESIGN FOR ITS STRUCTURAL COMPLIANCE <br />WITH SECTION R301 OF THE FLORIDA BUILDING CODE, <br />RESIDENTIAL 6TH ED., AND IS NOT RESPONSIBLE FOR <br />THE DESIGN'S ARCHITECTURAL AND/OR DRAFTING <br />CRITERIA (I.E. - DIMENSIONS, AESTHETICS, CONTINUITY <br />OF LAYOUTS, ETC.) ANY DISCONTINUITY IN DESIGN IS <br />THE RESPONSIBILITY OF THE DESIGNER. <br />CONFLICTS <br />(THE FOLLO PLY U.N.O.) <br />• REGARDLESS OF ANY NOTE TO THE CONTRARY IN THE PLAN SET, <br />EXCEPT AS INDICATED BELOW, IN ANY LOCATION WHERE THE PLAN <br />SPECIFICATIONS SEEM TO CONFLICT WITH THEMSELVES, THE CODE, <br />OR THE MANUFACTURER'S SPECIFICATIONS, THE MOST STRINGENT <br />CRITERIA SHALL APPLY. <br />• WHERE A SEALED DIRECTIVE FROM THE ENGINEER OF RECORD IS <br />PROVIDED RELATING TO A CONFLICTED ITEM, THAT DIRECTIVE SHALL <br />CONTROL. <br />DISCLAIMER <br />(THE FOLLOWING PLY U.N.O.) <br />CONTRACTOR IS TO VERIFY ALL DIMENSIONS IN THE FIELD AND REPORT <br />ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING ANY WORK. <br />ANY CHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT <br />WRITTEN, SEALED APPROVAL OF VORTEX ENGINEERING, LLC, OR ANY <br />CONSTRUCTION EXECUTED FROM THESE PLANS WITHOUT THE EXPRESS <br />APPROVAL OF VORTEX ENGINEERING, LLC SHALL AUTOMATICALLY RENDER <br />VORTEX ENGINEERING, LLC. HARMLESS TO ANY LIABILITY, CLAIMS, SUITS, <br />OR LITIGATION BY ANY INTERESTED PARTIES IN THE PROJECT. IF BOUND <br />SPECIFICATIONS ACCOMPANY THESE PLANS, THEY SHOULD BE READ <br />CAREFULLY FOR ADDITIONAL CONDITIONS. <br />�\\\\`N RAN//( /// <br />• <br />��� OP''� N qLF �1i <br />v .0,, i� <br />* <br />�k.. - <br />lz� <br />Qom' 8I 3, Z <br />*= 4T <br />4_11 ;*= <br />�O • STATE OF ; wk <br />��_��,*-.;c�ORID�' <br />•••``'��' <br />f//iS/OIVAL <br />�* �1� <br />///111I 11O <br />w <br />u ui <br />>- <br />� IS Z=- <br />r aw rOw <br />Np,Z <br />rDw Cza7 <br />Wr n <br />�W=ro <br />DOE o= °zo w <br />Om <br />Wmo 3.a o>wizu <br />a <br />-mo0W <br />tw w a2v�aQ-d u_rYz <br />a(D f- <br />��LLJ =�a�gw cn <br />rzn z zw'z�z 0 <br />11 <br />w �zawo <br />>Wow .FDw=a 0 <br />MO � zr0 Lu w z <br />W W v 2 w w �n J <br />= S n r i r w=� Q <br />- ¢ = a w - = IIIr <br />0 w N <br />a � <br />00 a i N <br />u <br />J Mo N M lD <br />ul 00 00 <br />L0 m �* *t <br />ii I�w- <br />..z M� w w w <br />..Z W F 0 00 m _ Z <br />... yj Vn w o w w Q <br />Z w 0 w 2 N Y <br />0LLj 0 <br />Z X�LU <br />00 2 a' <br />W LL, v 0 -; <br />. X Q z r, � 3 0 <br />UJ vi g � a L w <br />0 <br />O`°CC <br />QQ <br />It <br />O <br />O <br />Z N <br />4 <br />O O <br />> u') <br />M O� <br />C <br />a <br />0L_j2: O I <br />i L� <br />~ Q, <br />> ru ,_..I <br />d� <br />Q <br />Z fu <br />r6 <br />o }- <br />wZ <br />W <br />J <br />d' <br />mi <br />U) <br />uj <br />F__" <br />O U) <br />J <br />z_ <br />.j < <br />< �- <br />0� W <br />to <br />::) <br />I_ 0 <br />V <br />m <br />U) <br />SCALE: AS NOTED <br />DATE: 03-11-2019 <br />SHEET NO. <br />