Laserfiche WebLink
EXTERIOR PLASTER <br />ON FRAME <br />12 <br />5� <br />25 SH 25 SH <br />CJ <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />12 <br />�5 <br />1/2 33 SH <br />------ ------ ---------- ------------------------I--- 2ND FIN. FLR. <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON CMU <br />CJ / WEEP <br />35 SH <br />HDR <br />FIN. <br />REAR ELEVATION — ELEV—B <br />SCALE: 1 /4" = V-0" <br />rrnrnr�r Ann n"1K1fNI r• Ir.InTA1 I rf An Ml M <br />RIGHT ELEVATION — ELEV—B <br />SCALE: 1/4" = 1'-0" <br />=RIOR <br />3TER ON <br />AE <br />-URED <br />ENTITIOUS <br />;H ON CMU <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />txtenor covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having a 7/16" head, or 1-1/2" long, <br />16 gage staples, spaced in accordance with ASTM C1063 or <br />C1787, or as otherwise approved. (Refer to sheet SN1 for the <br />engineered method for Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4"-1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09,24.21 <br />a+7 <br />cu <br />r- <br />:e <br />-W <br />Z <br />fro <br />c C= <br />ci <br />•N 'tJ N t <br />a� a, <br />E <br />C, COD.� <br />�5: -ow <br />coil <br />CM <br />4n Q- <br />0 <br />is O <br />M <br />0 <br />CV <br />N <br />O <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />'.I N <br />W <br />o 0 <br />m0) <br />Ov <br />G <br />N N <br />Co N r <br />M <br />M <br />Y/ <br />to <br />Vi r Z P � J <br />W <br />a <br />a N. CT 3 <br />C: _ w w <br />w LL a <br />z <br />0fY <br />J LU <br />@ Ern a R <br />:3 Cc 0 Y <br />W_ <br />in�°jO' of w <br />u <br />00 <br />N N Z ¢ J <br />Z <br />O U < v <br />W <br />E10 <br />(D M c'n- <br />o g <br />z <br />z o <br />J <br />V) <br />M <br />Z a <br />lL <br />4-1 <br />Ca <br />f/J <br />w <br />0 <br />to <br />w <br />�fLS <br />.D <br />CD <br />I— <br />CJ <br />allW <br />0 <br />1 <br />_ N <br />U 0 <br />c rn <br />M <br />o <br />JZ <br />w <br />M <br />M <br />z ¢ <br />zC <br />Z <br />Q <br />ti <br />�a <br />zo <br />z® <br />p <br />E U <br />s� <br />Fz <br />❑a <br />o <br /><= <br />� g <br />��° <br />Wo <br />? o <br />aZ <br />a It <br />C/) L <br />¢z <br />0. <br />m0 <br />O� <br />Z <br />m J <br />ym <br />F ^ <br />aw <br />� <br />O <br />o g <br />Z <br />a0 <br />a <br />z <br />�w <br />W <br />0 <br />=r <br />M <br />v <br />wF <br />5 <br />a0 <br />003 <br />.o <br />G 0 <br />�cy) <br />O <br />N <br />rn <br />12 <br />m <br />C9 <br />(0 LO <br />T <br />N <br />Q- <br />LO <br />Q <br />CF Y <br />°O <br />J <br />N <br />a. <br />U) o <br />N <br />m <br />O <br />0 <br />cc N <br />m <br />O <br />N <br />Q <br />N <br />T <br />E <br />w <br />+= <br />CO t{) <br />o <br />Z <br />z <br />E <br />E r <br />� <br />W <br />E <br />U <br />a. <br />-1 <br />Q p <br />JOB <br />NO: <br />23-04906 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />2.2 <br />