My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6426 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6426 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:53:25 PM
Creation date
2/19/2025 10:59:57 AM
Metadata
Fields
Template:
Building Plans
Street #
6426
Location
Back Forty Lp
Contractor
Lennar Homes LLC
Building Plans - Permit #
6516
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />MA_ `IN <br />200 amp <br />150 amp <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.—� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />4 to lights & outlets <br />2 to appliances and GFI <br />0 to wH <br />to Range <br />to HVAC <br />200=410 in 2" Conduit <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV.03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />PZ�G. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF-SWITCHED DUPLEX OUTLET <br />Ia <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4. <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />�_o <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />e USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />IMM <br />ELECTRIC METER <br />PP11 <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />0 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />1.5" VTR <br />I <br />II, <br />I <br />I <br />—11I 3" VTR <br /><� I I <br />R" \/TR <br />SWITCH <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />C <br />11 DEDICATED <br />RECEPTACLE FOR <br />ICROWAVE RANGE <br />HOOD PER SPECS <br />WP A/C PAD <br />GFIDISC. <br />�JDB <br />I <br />/ I <br />IENTRY�P <br />DB & GFI TO I GFI <br />REALIGNED ------- <br />VERTICALLY <br />I <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />W 0� <br />w w <br />^W Z <br />Om <br />job <br />COACH LIGHTS COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS \ �. PER SPECS <br />SPEC 3 & 4 KITCHEN FIRST FLOOR ELECTRICAL PLAN - ELEV-13 <br />SCALE: %4"=1'-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />L----------I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —� <br />SECOND FLOOR ELECTRICAL PLAN <br />144wWon <br />ev <br />0 <br />!1 <br />> u, <br />c as e� N <br />e o0 <br />y. C9 N t <br />� 3 <br />O 2 V 6f <br />a� <br />E <br />�g <br />>o <br />0 <br />CV <br />CV <br />_o <br />y;- <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />v E <br />SO <br />0 N <br />N O <br />rtiCO <br />d <br />It <br />_j 3�3 LL w <br />u_ 3 0 <br />a <br />t <br />Z roc mom_ <br />4 <br />W ornrn <br />S4" 1LL <br />W t7 m w <br />Z Q <br />Z co Cl) <br />a0400 <br />Z O U o <br />W El El <br />M � <br />� � So <br />� m <br />N <br />` ^ M <br />I u- <br />Q) UI o <br />- <br />O N <br />�N U) <br />tisa <br />— E <br />��x <br />y //gypp <br />C) O N <br />ID <br />N � <br />0 <br />o <br />w <br />CO <br />m <br />Z <br />Z <br />a <br />LL <br />p <br />zo <br />>N <br />Z <br />>= U <br />" j <br />o a <br />l� ra <br />L. <br />00 <br />CD E <br />co <br />o¢ <br />�� <br />o0 <br />oa <br />r <br />= <br />az <br />o <br />p <br />Wz <br />Cn <br /><o <br />z <br />Y <br />Lo <br />m� <br />o <br />01 � <br />ZF <br />C 0 J <br />m <br />m <br />¢' <br />Q W <br />�z <br />a <br />go <br />T <br />m <br />o <br />w 0 <br />M <br />Qo <br />_ w <br />aF <br />'0 <br />z�< <br />Qo <br />8 <br />0 <br />0 <br />> CY) <br />N <br />I..L <br />0 <br />rn <br />ca <br />t— <br />N Q- <br />LO <br />Q <br />cr °O <br />N <br />+a <br />LO <br />.� <br />o U_ <br />r, <br />to N <br />m <br />M <br />O <br />N <br />a N CN <br />v <br />m <br />w <br />d % <br />o <br />Z <br />z <br />i6 <br />E t— <br />to <br />a <br />E <br />0 _ ¢ o <br />JOB <br />NO: 23-04906 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.