ATTIC VENTILATION CALCULATIONS - B1 <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN, of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev ) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />21.00000 <br />2.000000 <br />Floor <br />2377 <br />2282 <br />326 <br />1141 <br />81 <br />570 <br />0 <br />591.0 <br />315.0 <br />276.0 <br />(Zone 1) <br />**NOTE* <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN <br />SCALE: %4'=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA I UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT, <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. <br />*" (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />**Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT <br />**Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed <br />La <br />0V <br />z M <br />a <br />z� <br />Q <br />J <br />dv <br />z <br />U)V) <br />Q <br />w <br />a--+ <br />LU <br />O <br />F_ <br />N <br />to <br />o 0 <br />'— <br />Co 04 <br />04 <br />U <br />Lij <br />t— E <br />O <br />a� M <br />C N CO <br />m -o Q <br />`4 <br />U <br />S dj <br />O o <br />L LL co <br />N <br />� fl o <br />O <br />Y <br />Q rn <br />to V <br />M ¢ d <br />Al <br />MID®,'��fi/ <br />I <br />NCB�D �C <br />/ <br />g <br />vuvv <br />-,{A�9�4 • � O <br />♦ <br />CO <br />ID <br />LA73 <br />W ul <br />IIIIIIIIII�II� <br />O � <br />0 UM V <br />/gyp <br />O <br />�,W <br />To the best of the Engineer's kr�AkfeVJ9,7information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />z (V <br />O n <br />o <br />r>i M O <br />M <br />Q(n-0Lr) <br />a tn•��t <br />LL <br />ss ^ <br />U <br />a <br />l000 <br />� <br />z <br />WUJ <br />J � <br />Oz <br />O <br />w� <br />zaa <br />f a <br />r~ <br />u Q ix <br />UZOp <br />Z ZQ <br />L) <br />2 f W <br />U N WOO <br />Z0 <br />Z <br />Fz <br />Oro <br />1� <br />a <br />M <br />> <br />C <br />0 <br />U <br />U-) <br />— <br />J <br />CL <br />�W <br />o9 <br />0 <br />1, <br />O <br />�Rzo <br />x �5 <br />.;-. `; <br />O <br />U a m a <br />oaoa <br />N <br />` <br />U Q <br />Q <br />Q <br />O X C) <br />��Q <br />WzJ <br />Ln <br />rl <br />LL <br />�90,u- <br />? a =,,ozU <br />c <br />G <br />Q <br />W U <br />2 he <br />W <br />^ <br />L / <br />Ln <br />z <br />z <br />a z <br />Cy <br />nZ <br />z <br />m <br />rn <br />Q <br />J <br />= <br />Qo <br />,-+ <br />0- <br />cn <br />SCALE : AS NOTED <br />DATE : 1 /4/2018 <br />TECH: ERAN D <br />VERSION NO. 10 <br />SHEET NO. <br />5.0 <br />