+A. <br />TERMITE SPECIFICATIONS: <br />1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL <br />BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR <br />ELECTRIC PANEL.(FBC 104.2.6) <br />2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" <br />AWAY FROM BUILDING SIDE WALKS.(FBC 1503.4.4) <br />3. IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS <br />SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS.(FBC 1503.4.4) <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL <br />COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAT 6 INCHES. <br />EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINISH LESS THAN 5/8" <br />THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.(FBC 1403.1.6) <br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL <br />IS COMPLETE.(FBC 1816.1.1) <br />6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />INCLUDING SPACES BOXED AND FORMED.(FBC 1816.1.2) <br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, <br />ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT <br />FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF <br />SOIL AFTER THE INITIAL TREATMENT.(FBC 1816.1.3) <br />8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS <br />REQUIRED.(FBC 1816.1.4) <br />9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT.(FBC 1816.1.5) <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS.(FBC 1816.1.6) <br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION <br />IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER <br />THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED.(FBC 1816.1.6) <br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT.(FBC 1816.1.7) <br />13. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT <br />BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY <br />WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING <br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES."(FBC 1816.1.7) <br />14. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, <br />TUB TRAY BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />(FBC 2303.1.3) <br />15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED <br />WITHIN 15'-0": OF ANY BUILDING OR PROPOSED BUILDING.(FBC 2303.1.4) <br />ABBREVIATIONS <br />A.B. <br />Anchor Bolt <br />F.B.C. <br />Florida Bldg. Code <br />Opn'g. <br />Opening <br />Abv. <br />Above <br />Fin. Flr. <br />Finished Floor <br />Opt. <br />Optional <br />A/C <br />Air -Conditioner <br />F.G. <br />Fixed Glass <br />Pc. <br />Piece <br />Adj. <br />Adjustable <br />Flr. <br />Floor <br />Ped. <br />Pedestal <br />A.F.F. <br />Above Finished Floor <br />Fdn. <br />Foundation <br />P.L. <br />Parallam <br />A.H.U. <br />Air Handler Unit <br />Flr. Sys. <br />Floor System <br />PLF <br />Pounds per linear foot <br />ALT. <br />Alternate <br />F.PI. <br />Fireplace <br />Plt. Ht. <br />Plate Height <br />B.C. <br />Base Cabinet <br />Ft. <br />Foot / Feet <br />Plt Sh. <br />Plant Shelf <br />B.F. <br />Bifold Door <br />Ftg. <br />Footing <br />PSF <br />Pounds per square foot <br />Bk Sh <br />Book Shelf <br />FX <br />Fixed <br />P.T. <br />Pressure Treated <br />Bm. <br />Beam <br />Galy. <br />Galvanized <br />Pwd. <br />Powder Room <br />BOT. <br />Bottom <br />G.C. <br />General Contractor <br />Rad. <br />Radius <br />B.P. <br />Bypass door <br />G.F.I. <br />Ground Fault Interrupter <br />Ref. <br />Refrigerator <br />Brg. <br />Bearing <br />G.T. <br />Girder Truss <br />Req'd. <br />Required <br />Cir. <br />Circle <br />Hdr. <br />Header <br />Rm. <br />Room <br />Clg. <br />Ceiling <br />Hgt. <br />Height <br />Rnd. <br />Round <br />Col. <br />Column <br />HB <br />Hose Bibb <br />R/SH <br />Rod and Shelf <br />Comp. <br />A/C Compressor <br />Int. <br />Interior <br />SD. <br />Smoke Detector <br />C.T. <br />Ceramic Tile <br />K/Wall <br />Kneewall <br />S.F. <br />Square Ft. <br />D <br />Dryer <br />K.S. <br />Knee Space <br />Sh. <br />Shelves <br />Dec. <br />Decorative <br />Laun. <br />Laundry <br />SHT <br />Sheet <br />Ded. <br />Dedicated Outlet <br />Lay. <br />Lavatory <br />S.L. <br />Side Lights <br />Dbl. <br />Double <br />L.F. <br />Linear Ft. <br />S.P.F. <br />Spruce Pine Fir <br />Dia. <br />Diameter <br />L.T. <br />Laundry Tub <br />Sq. <br />Square <br />Disp. <br />Disposal <br />Mas. <br />Masonry <br />S.Y.P. <br />Southern Yellow Pine <br />Dist. <br />Distance <br />Max <br />Maximum <br />Temp. <br />Tempered <br />D.S. <br />Drawer Stack <br />M.C. <br />Medicine Cabinet <br />Thik'n. <br />Thicken <br />D.V. <br />Dryer Vent <br />Mfgr. <br />Manufacturer <br />T.O.B. <br />Top of Block <br />D.W. <br />Dishwasher <br />Micro. <br />Microwave <br />T.O.M. <br />Top of Masonry <br />Ea. <br />Each <br />Min <br />Minimum <br />T.O.P. <br />Top of Plate <br />E.W. <br />Each Way <br />M.L. <br />Microlam <br />Trans. <br />Transom Window <br />Elec. <br />Electrical <br />Mir. <br />Mirror <br />Typ. <br />Typical <br />Elev. <br />Elevation <br />Mono <br />Monolithic <br />UCL <br />Under Cabinet Lighting <br />Ext. <br />Exterior <br />N.T.S. <br />Not to Scale <br />U.N.O. <br />Unless Noted Otherwise <br />Exp. <br />Expansion <br />VB <br />Vanity Base <br />Vert. <br />Vertical <br />V.L. <br />Versalam <br />VTR <br />Vent through Roof <br />W <br />Washer <br />W/ <br />With <br />W/C <br />Water Closet <br />W.A. <br />Wedge Anchor <br />Wd <br />Wood <br />WP <br />Water Proof <br />MASTER REVISIONS <br />DATE I DESCRIPTION <br />STRUCTURAL NOTES: <br />FOUNDATIONS <br />SOIL TO BE COMPACTED TO AT LEAST 95% <br />OF MAX. DRY DENSITY AS DETERMINED BY <br />ASTM - 1557 ( MODIFIED PROCTOR) <br />FOUNDATION INSPECTIONS <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A <br />COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING <br />INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE <br />EXPOSED AND A STRING STRETCHED FROM MARKER TO <br />MARKER TO VERIFY REQUIRED SETBACKS. <br />CAST IN PLACE CONCRETE <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS OF 3000 PSI, A SLUMP OF 6" <br />PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT, <br />AND A MAXIMUM WATER/CEMENT RATIO OF 0.63 <br />2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC <br />DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 <br />GRADE 40. <br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />WWF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT <br />LEAST ONE CROSS WIRE WITHIN THE 6". <br />4. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF <br />ALL TOP BARS OF BEAMS. <br />5. HORIZONTAL FOOTING BARS SHALL BE BENT 1'-0" <br />AROUND CORNERS OR CORNER BARS WITH A 2'-0" <br />LAP PROVIDED <br />6. MINIMUM LAP SPLICES ON ALL REINFORCING BAR <br />SPLICES SHALL BE 40 BAR DIAMETERS TYP. <br />7. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR <br />1 1/2" TO FORM <br />REINFORCING STEEL <br />ALL REINFORCING STEEL SHALL BE NEW DEFORMED BARS <br />FREE FROM RUST, SCALE & OIL & SHALL MEET ASTM A-615 <br />REINFORCING FOR FOOTING SHALL BE SUPPORTED ON PRE- <br />CAST CONCRETE PADS, TOP REINFORCING SHALL BE <br />POSITIVELY SUPPORTED BY TEMPORARY STRINGERS. <br />DOWELS FOR COLUMNS & FILLED CELLS SHALL BE SECURED <br />IN PLACE BY USING ADDITIONAL CROSS- REINFORCING TIED <br />TO FOOTING REINFORCING. SPLICES IN REINFORCING WHERE <br />PERMITTED SHALL BE THE FOLLOWING MINIMUM, UNLESS <br />OTHERWISE INDICATED ON THE DRAWINGS: <br />FIGS, WALLS, COLUMNS, BEAMS, SLABS: 36 DIA. OR 2'-0" MIN., WHICHEVER IS MORE. <br />FILLED CELL REINFORCING: 40 DIA. OR 2'-0" MIN., WHICHEVER IS MORE. <br />TEMPERATURE REINFORCING: 20 DIA. OR 1'-0" MIN., WHICHEVER IS MORE. <br />WELDED WIRE MESH: 8" LAP <br />MASONRY WALL CONST. <br />1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL <br />WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, <br />WITH A MINIMUM NET COMPRESSIVE STRENGTH OF <br />1900 PSI (f'm = 1500 PSI ) <br />2. MORTAR SHALL BE TYPE "S", CONFORMING TO <br />ASTM C270. <br />3. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A <br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM <br />COMPRESSIVE STRENGTH OF 3000 PSI SLUMP 8" TO 11". <br />4. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE <br />DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. <br />5. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION <br />AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING <br />OF 192 BAR DIAMETERS. REINFORCEMENT SHALL BE PLACED <br />IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS <br />OTHERWISE NOTED. <br />6. REINFORCING STEEL SHALL BE LAPPED A MINIMUM OF 40 BAR <br />DIAMETERS, UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />7. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC <br />SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO <br />PREVENT THE FLOW GROUT INTO CELLS BELOW. THE USE OF FELT <br />PAPER AS A STOP IS PROHIBITED. <br />WOOD CONSTRUCTION <br />1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA <br />"NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION", LATEST EDITION. <br />2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR <br />WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS, <br />( I.E. BLOCKING OR GABLE END BRACING ) SHALL BE EITHER <br />SOUTHERN PINE, OR S.P.F. NUMBER 2 GRADE SHALL BE <br />USED REGARDLESS OF SPECIES. <br />ALL WORK SHALL COMPLY WITH ALL <br />PREVAILING CODES, FLORIDA BUILDR,'' <br />CODE, NATIONAL ELECTRIC CODE AND <br />C;'1Y OF, ZEPHYRHILLS ORDINANCES <br />(REVIEWED <br />MAY 0 9 2005 <br />3. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT <br />HAVE HOLES IN THE CENTER OF THE STUD UP TO 1" DIA. <br />SHALL HAVE STUD PROTECTION <br />SHIELDS FOR ALL HOLES OVER 1" IN DIA. <br />FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH <br />SIMPSON HSS2 STUD SHOES,TYP., U.N.O. <br />WOOD FRAMING INSPECTION <br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL <br />ROUGH -INS MUST BE COMPLETE, INSPECTED <br />AND APPROVED BEFORE REQUESTING FRAMING <br />INSPECTION. <br />PREFABRICATED WOOD TRUSSES <br />1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY <br />FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH <br />HURRICANE CLIPS OR ANCHORS. <br />2. PREFABRICATE WOOD TRUSSES SHALL BE DESIGNED IN <br />ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL <br />DESIGN SPECIFICATION FOR STRESS -GRADE LUMBER AND <br />ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL <br />FOREST PRODUCTS ASSOCIATION. <br />3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPOR- <br />TIONED ( WITH A MAXIMUM ALLOWABLE STRESS INCREASE <br />FOR LOAD DURATION OF 25%) TO WITHSTAND THE LIVE <br />LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. <br />4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS <br />REQUIRED BY THE TRUSS MANUFACTURER UNLESS <br />NOTED ON THE PLANS. <br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL <br />CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE <br />NOT SHOWN, BUT SHALL BE DESIGNED BY THE TRUSS <br />MANUFACTURER IN ACCORDANCE WITH THE FOLLOWING <br />DESIGN LOADS: <br />6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL <br />PLATE CONNECTED WOOD TRUSSES PER THE TRUSS <br />PLATE INSTITUTE TPI LATEST EDITION. <br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY <br />THE MANUFACTURER IN ACCORDANCE WITH SPECIFIED LOADS <br />AND GOVERNING CODES . SUBMITTALS SHALL INCLUDE TRUSS <br />FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, <br />BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIONS, AND <br />AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED <br />FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH <br />SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA <br />REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />8. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS <br />WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. <br />TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL <br />BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. <br />UPLIFT CONNECTORS <br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS <br />ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON <br />MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT FORCES. <br />INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED <br />TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD <br />NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE CONSULT <br />THE TRUSS ENGINEERING FOR THE LOCATION OF THESE WALLS. <br />STRUCTURAL DESIGN CRITERIA <br />CODES: <br />FLORIDA BUILDING CODE, 2001 EDITION WITH 2003 REVISIONS <br />BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02) <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301-02) <br />BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-02) <br />NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2001 EDITION <br />APA PLYWOOD DESIGN SPECIFICATION <br />LIVE LOADS: <br />ROOF 20 PSF (REDUCIBLE) <br />RESIDENTIAL FLOOR, UNLESS OTHERWISE INDICATED 40 PSF <br />BALCONIES 40 PSF <br />STAIRS 40 PSF <br />LIGHT PARTITIONS (DEAD LOAD), U.N.O. 20 PSF <br />10 PSF ATTIC L.L. <br />WIND LOADS: <br />WIND LOADS BASED ON FBC, SECTION 1606.2. <br />(F.B.C.) <br />WIND VELOCITY: 123 M.P.H., USE FACTOR: 1.0 <br />CONCRETE <br />ALL CONCRETE UNLESS OTHERWISE INDICATED 3000 PSI <br />STRENGTH <br />PEA GRAVEL CONCRETE FOR MASONRY CELLS ONLY 3000 PSI <br />0 28 DAYS <br />(DO NOT USE FOR CONCRETE COLUMNS OR TIE BEAMS) <br />REINFORCING: <br />WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 <br />ALL REINFORCING BARS ASTM A615-40 40,000 PSI <br />ALL STIRRUPS AND TIES ASTM A615-40 40,000 PSI <br />CONCRETE <br />ASTM C90-99b, STANDARD WEIGHT UNITS, fm=1500 PSI <br />MASONRY <br />MORTAR TYPE "S" 1800 PSI <br />UNITS: <br />CONCRETE GROUT 3000 PSI <br />CONTINUOUS MASONRY INSPECTION IS REQUIRED DURING CONSTRUCTION <br />STRUCTURAL <br />ALL STRUCTURAL AND MISCELLANEOUS STEEL A36 36,000 PSI, U.N.O <br />STEEL: <br />SHOP AND FIELD WELDS: E70XX ELECTRODES <br />ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 <br />WOOD FRAMING: <br />BEAMS, RAFTERS, JOIST, PLATES, ETC. U.N.O. <br />NO. 2 SOUTHERN YELLOW PINE (19% M.C.) <br />ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR, or OSB <br />FLOOR SHEATHING: T&G A-C GROUP 1 APA RATED (48/24) <br />WALL SHEATHING: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />VERSA LAM BEAM Fb = 2900 PSI (2.OE) <br />WOOD COLS. PARALLAM 2.0E U.N.O. <br />WOOD ROOF <br />DESIGN LOADS: <br />TRUSSES: <br />TOP CHORD LIVE LOAD: 20 PSF <br />TOP CHORD DEAD LOAD: 10 PSF <br />BOTTOM CHORD DEAD LOAD: 10 PSF <br />40 PSF <br />BOTTOM CHORD ATTIC LIVE LOAD: 10 PSF <br />SEE DRAWINGS FOR SPECIAL CONCENTRATED LOADS. DESIGN <br />FOR NEW WIND UPLIFT AS PER SPECIFIED CODES, DEDUCTING <br />A MAXIMUM OF 5 P.S.F. DEAD LOAD, BUT NOT EXCEEDING ACTUAL <br />DEAD LOAD. <br />WOOD FLOOR <br />DESIGN LOADS: <br />TRUSSES: <br />DEAD LOAD: 15 PSF <br />LIVE LOAD: 50 PSF <br />TOTAL: 65 PSF <br />SOIL BEARING <br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF <br />VALUE: <br />SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS <br />IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY <br />THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO <br />FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. <br />BUILDING DATA <br />CONSTRUCTION TYPE - TYPE VI UNPROTECTED WIND SPEED 123 MPH (3 SEC. GUST) <br />(SECTION 608 - FBC 2001) WIND IMPORTANCE FACTOR - (Iw) = 1.0 <br />MEAN ROOF 15 FT. HIGH WIND EXPOSURE - "B" (FBC 1606.1.8) <br />TYPICAL FOR SINGLE HOMES INTERNAL PRESSURE COEFFICIENT = +/ 0.55 (PARTIALLY <br />ENCLOSED BLDG) <br />DESIGN WIND PRESSURE: <br />(COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) <br />WINDOWS AND DOORS <br />123 MPH + 38 PSF / - 40 PSF <br />GARAGE DOORS (V = 123 MPH) <br />SINGLE 9x7 +37.0 PSF / -40.0 PSF <br />DOUBLE 16x7 +37.0 PSF / -41.0 PSF <br />SEE FLOOR PLAN FOR ACTUAL PRESSURES <br />ENGINEERED PLANS <br />ON FILE <br />COLONIAL ANDE 2003 <br />GENERAL NOTES: <br />Qo <br />y ° <br />�o <br />oQ��� <br />wa <br />ma <br />w0LL <br />0ZZ <br />� m <br />THE FOLLOWING TECHINCAL CODES <br />wo <br />U Xo Z) LL L) <br />y <br />o p <br />SHALL APPLY: <br />frp z U <br />(- CL 2 UJ ¢ <br />a c7 <br />2001 FLORIDA BUILDING CODE, <br />w C) d 0 <br />4) <br />o <br />WITH 2003 REVISIONS <br />PLUMBING , MECHANICAL, FUEL GAS, <br />W " w <br />w w¢ o <br />(Aw <br />-' <br />m <br />ENERGY EFFICIENCY, ACCESSIBILITY, <br />AND NFPA 70-02 <br />0 <br />C� ow Y o 0 <br />Q � Z <br />0 <br />v Cr <br />NATIONAL ELECTRICAL CODES <br />II-- p 0 <br />o <br />Dw-w <br />O a<Z2 <br />+ W <br />w <br />O wu,w¢z <br />0 <br />w < 0 <br />0 <br />mo o <br />1. TANK TYPE WATER CLOSET VOLUME <br />1.6 GALLONS <br />IX z o- - <br />Q LL <br />��" m <br />t <_J <br />2. WALL MOUNT WATER CLOSET VOLUME <br />g w o a <br />Er o � -' ¢ <br />a ¢ Z m <br />N m <br />p 0 <br />3.5 GALLONS <br />3. WATER FLOW RATE. <br />(n a ¢ ui o ¢ <br />W fr_ <br />06 <br />uO p r-ti <br />PUBLIC FACILITIES 0.5 G.P.M. <br />; > ¢ z <br />+ <br />+ rn <br />PRIVATE FACILITIES 2.2 G.P.M. <br />a 0 3 ¢ 0 <br />SHOWER HEADS 2.5 G.P.M. <br />4. ALL WATER LINE PLUMBING <br />r z ao CS <br />Z <br />TO BE PVPC <br />~ W 3 m <br />rn <br />VTR LOCATIONS ARE APPROXIMATE <br />0 Z ''' < N `4 y <br />o Z 0 0 <br />m <br />AND MAY CHANGE DUE TO JOBSITE <br />LU 0 ¢ L) -� O <br />o Z <br />CONDITIONS <br />z Q 9 0 ��* . <br />�c�Z ,yea <br />OP Q <br />N <br />THE FOLLOWING SHALL COMPLY <br />z w aw_ o 0 W Z O <br />0 <br />E o <br />WITH THE 2001FBC. <br />LU <br />WZoMZ00aC Z <br />m N <br />❑ PORCHES AND BALCONIES <br />~ 0 Z i T J O 3 <br />M M C <br />SECTION1014 <br />❑ HANDRAILS - SECTION 1007.5 <br />0LL <a WU)a-Wm W <br />(n a ¢ ~ 0 ¢ m 0 <br />0NNw <br />co `m <br />❑ GUARDRAILS - SECTION 1015, 1019.9 <br />M n 0 < ==) �p <br />0 U- ao � v (o <br />N <br />❑ STAIRS SECTION 1007 <br />� 3 � n = Z <br />OJ <br />'CV:> W <br />i a <br />❑ CHIMNEY & FIREPLACE <br />SECTION 2804-2806 (MFGR) <br />oz�o~axurt <br />� � W 0 � Fn n❑❑ � <br />:Xmci <br />m < a- � 0 2 0 <br />SECTION 2113-2114 (MAS) <br />❑ EGRESS WINDOWS <br />E3 <br />SECTION 1005.4 <br />5. ALL OPENINGS SHALL COMPLY WITH <br />to <br />2001; FBC WIND LOADS AS STATED <br />W <br />BELOW. ATTACHMENTS OF WINDOWS, <br />DOORS, SLIDING GLASS DOORS <br />AND O.H. GARAGE DOORS ARE TO DELEGATED <br />It <br />THE MANUFACTURER OF THESE ITEMS. THE <br />N LIN <br />MANUFACTURER OF THESE ITEMS <br />SHALL SUBMIT ATTACHMENTS FOR <br />Z 0 r N <br />SITE INSTALLATION. <br />0 J M N <br />SEE ATTACHED SPECIFICATION SHEETS FOR <br />. <br />N In <br />MANUFACTURERS DESIGN CRITERIA AND <br />W M � <br />INSTALLATION METHODS FOR WINDOWS, <br />; <br />lz <br />DOORS, SLIDING GLASS DOORS, OVERHEAD <br />_ <br />M <br />O 0 <br />GARAGE DOORS, AND ROOFING. <br />.a <br />aNL� <br />IL <br />6. ALL DOORS INTERIOR & EXTERIOR ARE <br />m <br />6'-8" UNLESS OTHERWISE NOTED <br />Q in IL <br />ALL SHOWER ENCLOSURES TO BE <br />.w F W <br />'- <br />TEMPERED GLASS <br />a <br />7. ALL WINDOWS WITHIN 24" OF DOORS <br />(INTERIOR & EXTERIOR) AND WITHIN <br />-.. Z <br />18" OF FLR TO BE TEMPERED GLASS. <br />(SECTION 2405.2) <br />INDEX OF DRAWINGS <br />Zo <br />z w <br />z <br />� <br />UJ I— <br />SHT NO TITLE <br />ozN�¢ <br />° � - _' <br />z�'=3(n <br />¢Nww <br />z QoO <br />Cr <br />1 COVER SHEET <br />inw w LU Q <br />3 0 U <br />2 FLOOR PLAN <br />�oz <br />O�w <br />3 FOUNDATION PLAN <br />�>wo� <br />N a < <br />4 ELECTRICAL PLAN <br />5 ELEVATIONS <br />Z <br />6 TRUSS LAYOUT <br />Ln <br />S-1 MASONRY DETAILS <br />c-4 <br />c) <br />= <br />Lo <br />0 <br />LINTEL PLAN AND DETAILS <br />o <br />QMS-2 <br />DETAILS <br />LooS-3 <br />S-4 DETAILS <br />w <br />� <br />0 <br />S-5 DETAILS <br />S-6 DETAILS N <br />S-7 STRUC. NOTES & <br />O Cn <br />Lu <br />HANGER INFORMATION <br />J <br />0 <br />S-8 DETAILS <br />O _..I <br />z <br />w <br />o <br />S-9 DOOR DETAILS <br />N '- <br />Q <br />U <br />- <br />Z E Z <br />ao <br />Z <br />S-10 ROOFING DETAILS <br />Z <br />Z W > <br />S-10A ROOFING DETAILS <br />(� <br />C <br />O <br />o 0 <br />0Q <br />S-11 GARAGE DETAILS <br />J <br />Q <br />z <br />o w 0 <br />S-12 DETAILS <br />PRODUCT APPROVAL <br />W <br />Q <br />N <br />a <br />S-13 <br />- <br />_ <br />cr - <br />S-14 WINDOW DETAILS <br />- <br />Z <br />0 <br />m= Z <br />S-15 SGD DETAILS <br />w 0 <br />- <br />Cr <br />0 <br />S-16 D ETA I LS <br />LO F- <br />2 --� <br />a <br />S-17 DETAILS <br />Q p <br />��o <br />Ld <br />S-18 DETAILS <br />z V <br />O <br />a Z o <br />J <br />U <br />=¢ <br />NOTICE TO BUILDER <br />�_ 2 <br />Cr <br />IT IS THE INTENT OF THIS DESIGNER THAT <br />THESE PLANS ARE ACCURATE AND ARE <br />0 <br />O <br />SHEET NO. <br />a <br />CLEAR ENOUGH FOR THE LICENSED PROFESS- <br />ONAL TO CONSTRUCT THIS PROJECT. <br />Ld <br />IN THE EVENT THAT SOMETHING IS UNCLEAR <br />OR NEEDS CLARIFICATION..STOP..AND CALL <br />z N <br />OF <br />THE DESIGNER LISTED IN THIS TITLE PAGE. IT <br />w <br />25 <br />co <br />0 <br />IS THE RESPONSIBILITY OF THE LICENSED <br />PROFESSIONAL THAT IS CONSTRUCTING THIS <br />\ <br />LAST PLOT DATE <br />0 <br />March 11, <br />2005 <br />0 <br />O <br />PROJECT TO FULLY REVIEW THESE DOCUMENTS <br />�/� <br />BEFORE CONSTRUCTION BEGINS AND ANY AND 0 <br />ALL CORRECTIONS, IF NEEDED, TO BE MADE <br />COVER SHEET <br />BEFORE ANY WORK IS DONE. <br />