Laserfiche WebLink
A -(I) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(9) 10dx I J' NAILS TO TRUSS <br />B-(2) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(12) 16d X 1 J' NAILS TO TRUSS <br />DEL STRAP, 1 EACH SIDE WRAPS UP AND <br />OVER TRUSS (NOT SHOWN) <br />C-(l) SIMPSON LGT2 GIRDER TIEDOWN WITH <br />(16) 10d x 3 J'NAILS TO GIRDER AND <br />(2) SIMPSON HETA16 TRUSS ANCHORS <br />WITH (12) 16d X 3 � NAILS TO GIRDER <br />1)(2,2x WOOD FASCIA <br />SEE ARCHITECTURAL <br />2x SECURED W/ (3) 16d <br />GALV. COMMON NAILS. <br />IX2 SECUREDW/ 10d <br />GALV. COMMON NAILS <br />12'0/C <br />MASONRY BOND BEAM <br />SEE SCHEDULE <br />PLYWOOD SHEATHING, SEE <br />,ROOF/WALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE' <br />NOTE: A PT SYP #2 2' x 4*, <br />6', 8'xV-G* MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3- <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE TRUSS <br />ANCHOR REQUIREMENTS. <br />ENGINEEREDWOOO <br />TRUSSES 0 24- O/C, <br />SUBMIT SHOP DRAWINGS <br />FOR REVIEW <br />AND APPROVAL <br />A ALLOWABLE UPLIFT U: 1810 LES, L:T70 USS (1 PLY) <br />B ALLOWABLE UPLIFT U:2365 LOS, L 1430 LES (2 OR 3 PLY) <br />C ALLOWABLE UPLIFT U2705 LBS (2 PLY) <br />S1A 1B 1C TYPICAL TRUSS/ <br />(��IGIRDER CONNECTOR(S) <br />3/4. T & G SUBFLOO14 GLUEDAND <br />SCREWED AS PER SCHEDULE <br />PRE-ENG FLOOR TRUSS <br />518"GYPSUM BOARD OR 1/2"HIGH <br />STRENGTH CLG. BOARD <br />SECURE TRUSS TO TOP PLATE W/ (2) <br />16d TOENAILS <br />DOUBLE TOP PLATE <br />ENGINEERED WOOD TRU <br />0 24- O/C, SUBMIT SHOP <br />DRAWINGS FOR REVIEW <br />AND APPROVAL <br />(1) SIMPSON HETA16 <br />TRUSSANCHORWITH <br />(9) 1 Od X 1 J* NAILS TO <br />GIRDER, PROVIDE 5' <br />MINIMUM CONCRETE <br />EMBEDMENT. USED IN <br />CONJUNCTION WITH <br />HEAVY UPLIFT <br />CONNECTOR <br />PLYWOOD SHEATHING, SEE <br />'ROOF/WALL/FLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE: A PT SYP 42 2'x 4', <br />6', 8* . 4'-0' MAY BE ADDED <br />W1 I Dd NAILS, 2 ROWS, 3- <br />OIC TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE GIRDER <br />TIEDOWN REQUIREMENTS. <br />\—A-(l) SIMPSON LGT3-SOS2.5 GIRDER TIEDOWN <br />WITH (4) t X S'TITEN HD TO CMU AND (12) SDS <br />J' X 2 k TO GIRDER <br />B-(I) SIMPSON FGTR GIRDER TIEDOWN WITH <br />12) k X 5' TITEN HD TO CMU AND (18) SDS il x <br />lx2,2x WOOD FASCIA <br />3* TO GIRDER <br />SEE ARCHITECTURAL <br />C-(2) SIMPSON FGTR GIRDER TIEDOWNS WITH <br />2x SECURED W/ 13) 16d <br />(2)kxS'TITENHDTOCMUAND(18)SDS J"XT <br />GALV. COMMON NAILS. <br />1 X2 SECURED Wl I Od <br />MASONRY BOND SCREWS TO GIRDER (EACH TIEDOWN) <br />GALV COMMON NAILS <br />EAM <br />BEAM ENSURE THAT CELLS ARE GROUTED <br />12'010 <br />SEE SCHEDULE SOLID, WEACH WAY OF BOLTS <br />A ALLOWABLE UPLIFT 3285 LES (2 OR 3 PLY) <br />B ALLOWABLE UPLIFT 4725 LBS (2 PLY MIN.) <br />C ALLOWABLE UPLIFT 8WS LES 12 PLY MIN.) <br />_Y2 _Y_ C� TYPICAL ROOF <br />r2A 2B 2 —ox- 4 <br />GIRDER CONNECTOR(S) LL _` <br />LSTA12 20 GAUGE <br />W/ 10dxl/2 HOG NAILS <br />0 EACH END. TOTAL OF 10 <br />FLOOR <br />GIRDER <br />iTT4 W/ 6/8"AA, WITH <br />AIN. 7' EMBEDMENT <br />TO S�AB & (18) 16d <br />2X4 OR 2X6 WOOD BEARING 2-1/2 NAILS TO PDX <br />ST <br />WALL W/ SYP No 2 STUDS SEE POST TO SIT DIRECTLY <br />PLANS FOR SPACING. SINGLE ON SLAB <br />BTM. PLATE TO BE PT. <br />PROVIDE DEIL. TOP PLATE <br />PROVIDE BLOCKING <br />1/2' GYP. WL. BD. <br />tl �,GIRDER/WOOD POST CONNECTIONS <br />FLOOR TRUSS CONNECTION @ L.B.W. <br />SCALE: 3/4"-l'-O* (NO UPLIFT) <br />OUTER 1/3 ( <br />SPAN ONLY <br />BTM. - <br />PLATE <br />DEPTH 1/4*0 <br />—HOLE EDGE 15/8" <br />. 216*13 SGL. STUD <br />STUD NOTCHING <br />AND BORING LIMITS <br />EDGE >516' <br />� 3t5*0 DBL. STUD <br />A - SIMPSON HUS28 G � 1200 LES, U < 1280 LES W/ (1) 34- SIMPSON TITEN BOLT/J-BOLT, 51 MIN. <br />EMBED (22) 16d GALV. COMMON NAILS AND (8) 10d QALV. COMMON NAILS. <br />B - SIMPSON HUS28 G � 2400 LES, U � 1425 LES W/ (2) 314- SIMPSON TITEN BOLTIJ-BOLT, V MIN. <br />EMBED (22) 16d GALV. COMMON NAILS AND (10) 16d GALV. COMMON NAILS. <br />C - SIMPSON HGUS28-2 G � 2400 LBS, U < 1810 LEIS W/ (2) 3/4" SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN . EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS. <br />D - SIMPSON HGUS28-2 0 < 4800 LES, U < 1810 LBS W/ (4) 3/4- SIMPSON TITEN BOLT/J-BOLT, S' <br />MIN. EMBED (36) 1 6d GALV. COMMON NAILS AND (12)16d GALV. COMMON NAILS. <br />E - SIMPSON HGUS28-3 G � 4600 LES, U < 1810 LES W1 (4) 314- SIMPSON TITEN BOLTIJ-BOLT, 5' <br />MIN. EMBED (36) Ifid GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS. <br />WOOD LEDGER <br />ATTACHMENT DETAIL <br />9 SCALE: 3/4'=I'-O* <br />6'-0" MAX (W/1 X4) <br />R 10'-0" MAX (W12 !!llv_ <br />#1100 UPLIFT SIMPSON <br />HTSM20 W/10 10d TO <br />TRUSS AND (4)114'.21/4' <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br /># 1900 UPLIFT (2) SIMPSON <br />HTSM20 INSTALLED ON <br />OPPOSITE FACES OF <br />BLOCK WALL W/10 10d TO <br />TRUSS AND (4) 1/4'. 2 1/4' <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br />PRE-ENG TRUSS <br />CONTINUOUS BOND BEAM <br />TITEN 2 ANCHORS MIN, <br />2, COVER & 2'APART <br />REPAIR OF MULTIPLE <br />mispi-AdED EMBEDDED TRUSS ANCHOR <br />1 X4 DIA GONAL <br />BTM.CHORO <br />BRACING, SEE <br />PLAN FOR LOCATION <br />MAY NOT BE <br />REQUIRED <br />STM. CHORD OF <br />WOOD ROOF TRUSSES <br />IX4 BTM. CHORD BRACING 6-0"O/C END WALL OR OTHER <br />MAX., OR 2X4 EITM. CHORD BRACING END TYPE CONDITION, IF <br />101-0- O/C MAXSECURED W/ (2) 10d DEPICTED SEE PLAN <br />COMMON NAILS AT EACH CHORD <br />INTERSECTIONTYP. BTM. CHORD BRACING <br />5'EDGE <br />CENTRAL <br />SPACING <br />SPACING <br />SEE <br />S <br />5CHEDULE� <br />S2M��� WE TWIG Pf <br />L <br />SEE SCHEDULE FOR BOLT <br />LEDGER SCHEDULE Lu <br />5 112- MIN. EMBED. (TYP) <br />B 13 <br />1. ENSURE THAT EXP. BOLTS/J-HOLTS ARE <br />H, H <br />PLACED INTO GROUTED CELLS, S' ALL AROUND <br />BOLT. <br />2. END OF FRONT AND REAR LEDGER SHOULD <br />LAP A MIN OF 4'-D'. <br />3. ALL BOLTS TO HAVE WASHERS <br />4 EXP. BOLTS/J-BOLTS SHOULD NOT BE ANY <br />CLOSER THAN VC/C. <br />5. IN LIEU OF HILTI PAPS SIMPSON TITEN 1/4* <br />(2) PT <br />DIA. x 3' MASONRY SCREWS MAY BE USED. <br />LEDGER SCHEDULE <br />MARK <br />SIZE <br />BOLT SIZE <br />VEDGESPACING <br />CIROM&PACING <br />A <br />DOUBLE 2X8 <br />1/2" <br />81 O/C <br />16* O/C <br />B <br />DOUBLE 2xS <br />14- <br />81 Ole <br />24'O/C <br />C <br />DOUBLE 2xlO <br />1/2, <br />a, O/C <br />16, O/C <br />D <br />DOUBLE 2xI0 <br />11. <br />a* O/C <br />24' O/C <br />E <br />DOUBLE 2xI0 <br />3/4' <br />6'O/C <br />16, O/C <br />F <br />DOUBLE W2 <br />---- <br />I <br />WOOD LEDGER DETAIL <br />3/4'.V-0' <br />(2) 2X4 No.2 SYP DIAG. - <br />BRACE W/ (3) 12d 0 EA. <br />TRUSS (DIAG BRACE TO <br />COVER 6 TRUSSES) <br />0'-0- TO 30'-0' (1) 'X' BRACE <br />3U-l' TO EICY-0 (3) 'X' BRACE <br />�l :X B A E *CENTER <br />EIR C <br />RACE DIVIDED EQUALLY <br />FROM CENTER TO END. <br />2x WOOD FASCIA, <br />SEE ARCHITECTURAL <br />PRE-ENG GABLE TRUSS <br />STIFFBACK (AS PER <br />TRUSS ENG) <br />SEE SCHEDULE FOR <br />BOND BEAM REQ. <br />2x4 BLOCKING BETWEEN <br />TRUSSES WHERE <br />X-BRACING IS PRESENT AT <br />W-0- O.C. (AT SHEATHING <br />SEAMS) <br />SECURE 2XB PT. PLATE <br />TO SLK W1 1/2' DIA. <br />ANCHOR BOLT W/ 2' <br />WASHER SET IN HIGH <br />STRENGTH EPDXY 6' <br />MIN. EMBED. AT 32'OC <br />MAX. <br />SECURE GABLE TO 2X8 <br />P.T. PLATE W/ 12d'. 8* <br />O.C. MAX <br />CONT. 2X4 SECURED W/ <br />(2) lOds 0 EACH TRUSS <br />TO BE INSTALLED 0 <br />101-0'O.C. MAK <br />BLOCK WALL W/ GABLE END <br />1,� �-ENG�DTRU`S�� <br />THE USE OF ALTERNATE MATERIALS MAY BE <br />USED SO LONG AS THEY CONFORM TO THE <br />FOLLOWING <br />1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS <br />A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS <br />EQUIVALENT OR GREATER UPLIFT AND LATERAL fl AND F2) LOAD CAPACITIES <br />AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND <br />ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE <br />THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO <br />A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, Fl, AND F2 <br />FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE <br />SUBJECT TO Fl AND F2 FORCES. <br />ALTERN TE MATERIALS <br />LE: 3/4"-V�0" <br />1441. N, RONALD REAGAN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-774-6078 <br />FAK 407-7744078 <br />www.abdeslgngroup.com <br />AA#:O003325 <br />DRAFTING BY: <br />A.S. DESIGN GROUP <br />DRAFnNGINC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 8134M&2628 <br />FAX: 813-886-2802 <br />ISXMDIV. S& LWO <br />SILVERADO <br />LOT #22 <br />BLK #1 <br />pr.tojzcT# 1 <br />03719,000-22'01 <br />Tfd!�-CAMDEN <br />GARAGE EMNG: <br />LEFT <br />PAGE: <br />DETAILS <br />IQ50 MPH EXP. V <br />