My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7145 Boxer Round Pl
Zephyrhills
>
Building Department
>
Building Plans
>
7145 Boxer Round Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:58:01 PM
Creation date
2/19/2025 12:12:46 PM
Metadata
Fields
Template:
Building Plans
Street #
7145
Location
Boxer Round Pl
Contractor
DR Horton
Building Plans - Permit #
22278
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL ISE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED M NON -CONDITIONED AREAS SHALL ISE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB / MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NPPA WA 2-3J <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER MC 6TH EDITION (20n) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />T. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH F15C 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SP70KE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MIFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />W. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A PANTEC 4 DBF BOOSTER PAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />NOTE <br />ALL HVAC TO HAVE PAPER <br />PANS W/ DRAINS <br />ATTIC <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OW <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THR.1 AIR GRILL <br />"c'61"' <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />? <br />y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />RIGERANT LINES <br />REFVE'Tl <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />THRJU <br />WALL <br />y <br />TO OONC. <br />2)--3/16�X2' <br />CONDENSER <br />3/4' PVC CONDENSATE ORAN LINE <br />W/SECURE <br />TAP"_ <br />UNIT <br />SIMP'SON WB ROLL STRAP <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />OR EQUAL <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING WIT <br />TRAP DRAIN LINE AND TERMINATE <br />4' CONCRETE SLA15 SECURE STRAP TO WIT W/ l2) <br />�SXI I/4' BHt. MTL. SCREWS <br />IN AN APROVED ORAN, AS PER <br />MCR6TCALBOG.C4O) <br />MECHANICAL BLDG. CODE <br />CONDENSER UNIT <br />HVAC <br />SECTION 3V12A <br />DRAINS <br />CONNECTION TO PAD <br />NOTE, MAIN DRAIN 3/4' <br />* 12' <br />OVER HEAD 12FROM STRUCTURE <br />. <br />■ <br />SC0RIATED NICKEL FIN. FLOOR COUNTERSUNK <br />BRONZE FL. PL. OR WALL C.O. PLUG <br />BRASS PLUG <br />—� FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED 00 WADE 8240-K JOSAM 860 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPT[/SPEC <br />FLOOR SLAB CLEAN —OUT (TYPN) <br />FIN. GRADE <br />OR PAVING <br />SEE SPED. <br />1'-8'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />2 EXT. GROUND CLEAN —OUT (TY <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE, 114 . I'-C' <br />1441 N. RONALD REAGAN SLVD. <br />LONGWOOD, FL327W <br />PH: 407-774.6078 <br />FAX: 407-7744078 <br />wwwabdesigngroup.com <br />L AA #: 0003325 J <br />g <br />IN <br />atrBDiv ae ItAT: <br />SILVERADO <br />LOT #8 <br />BLK #18 <br />PROJECT# <br />04128.002-08181 <br />MODEia <br />3EFB <br />"2447— ROBIE" <br />GARAGE aw:NO: <br />LEFT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />50 MPH EXP. <br />-=ilk• � JI i•L i'L <br />D TE 10/09/19 <br />SCALE: 1/41 = r—o' <br />a M1 <br />