My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7145 Boxer Round Pl
Zephyrhills
>
Building Department
>
Building Plans
>
7145 Boxer Round Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:58:01 PM
Creation date
2/19/2025 12:12:46 PM
Metadata
Fields
Template:
Building Plans
Street #
7145
Location
Boxer Round Pl
Contractor
DR Horton
Building Plans - Permit #
22278
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT WALL DE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. RECUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB / MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLDG, CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL IN CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. PRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SELLER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, ALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE. TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />I. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH PBC 6TH EDITION (20(1) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9, ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/BMCKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 60T. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH POP BOOSTER FAN OR EQUAL. <br />FANTECH POP 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURRN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE. RETURN TRLINIC <br />1 <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECOND FLOOR <br />MECHANICAL PLAN <br />SCALE: 1/4 . P-O' <br />FREE DRAW AIR <br />HANDLER CLOSET <br />W/LOUVERED DOOR <br />SUPPLIED BY <br />BUILDER <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, F. 32780 <br />PH: 407-774.6078 <br />FAX: 407-774.4078 <br />www.abdesigngroup.com <br />AA A: 0003325 <br />p� <br />i <br />r <br />• <br />�sy <br />i3 <br />F <br />ifC <br />0 <br />b <br />avaaly. ae LOT: <br />SILVERADO <br />LOT #8 <br />BLK #18 <br />PROJECT <br />04128.001-08181 <br />MOaEIe <br />3EFB <br />"2447- ROBIE" <br />GARAGE 8WINa: <br />LEFT <br />PAGE: <br />SECOND FLOOR <br />MECHANICAL <br />PLAN <br />50 MPH EXP. <br />t�Lv <br />ROLA1� A <br />AR NC 90723 <br />,PRINT <br />A 10/09/19 <br />9CAI.E: 1/4• = 1'-0* <br />1 <br />Im <br />