Laserfiche WebLink
ipOR ASPHALT SHINGLE ROOF, USE MIN 7/16" STRUCTURAL <br />SHEATHING EXP 1(24/18) or 15132" STRUCTURAL SHEATHING EXP 1 <br />(32/18), FOR CEMENTITIOUS TILE AND METAL ROOFING, USE 15132' <br />STRUCTURAL SHEATHING EXP 1 (32116) .(SEE TABLE FOR FIELD AND <br />EDGE SPACING) SEE DETAIL <br />ROOF SHEATHING TO GABLE END FRAME USE 8d RING SHANK GUN <br />NAILS <br />0 4" O.C. EDGEWISE 2.4 BLOCKING ALL PANEL JOINTS Wq IN 4' <br />OF GABLE END. <br />SHEATHING <br />FASTENER SCHEDULE <br />NAIL REQUIREMENTS <br />SIZE <br />HEAD <br />LENGTH <br />DIA <br />TENSILE STIR. <br />SHANK <br />ASTM <br />8d <br />RING SHANK <br />23/8" <br />0.113 <br />170,000 <br />(11Ng <br />6-20 RINGS <br />F1067 <br />RSRS-01 <br />SCREW SHANK <br />PER INCH) <br />8d <br />RING SHANK <br />PNEUMATIC <br />2 3/8" <br />0.113 <br />F1667 <br />SCREW -NAILS <br />RSRS-0i <br />EXTERIOR SHEATHING <br />USE 1/7CDX OR 7/16" O.S.B. PLY WITH Sd RING SHANK GUN NAILS AT <br />4" O.C. AT PANEL SIDES AND Bd RING SHANK GUN NAILS 4" O.C. TOP & <br />BOTTOM PANEL AND Bd RING SHANK GUN NAILS AT W O.C. AT <br />INTERMEDIATE SUPPORTS OR 7/16" ZIP SHEATHING SYSTEM <br />(INSTALLED PER MANUF. SPECS.) SEE DETAIL. <br />ROOF SHEATHING ATTACHEMENT SPACING <br />ZONE 1:. 8d NAILS Q 4" O.C. ON EDGE AND W O.C. IN FIELD <br />ZONE 2B, 2n, 2' <br />8d NAILS ®4" O.C. ON EDGE AND 4" O.C. IN FIELD <br />ZONE 3,38, 3r Bd NAILS C 4" O.C. ON EDGE AND 4" O.C. IN FIELD <br />NDTE ROOF SHEATHING THICKNESS WAS CALCULATED <br />AND ADHERES TO ASCE 7-16 <br />8d RING SHANK GUN NAILS 0 4" O.C. <br />TOP 8 BOTTOM EDGES <br />li - <br />TYR. EXT. SHEATHING ATTACHMENT <br />RAFTER OR TRUSS —� <br />ROOF SHEATHING <br />p O <br />m <br />1, BUILDING LENGTH U <br />ROOF SHEATHING LAYOUT <br />AND ENOWALL BRACING <br />FOR GABLE END FRAMING <br />NOTE: GABLES -DROP GABLE END 8 (1) ADD'L DROPPED <br />TRUSS 2x4 #2 SYP OUTLOOKER RAFTER W/ BLOCKING G <br />18"0.C. IF NO DROPPED GABLE END, ATTACH 20 #2 SYP <br />BLOCKING G 16" O.C. FIRST 4 BAYS WN (2)12d NAILS EA. <br />END. ATTACH ROOF SHEATHING TO RAFTERS 2t <br />BLOCKING PER NAILING SCHEDULE <br />8d RING SHANK GUN NAILS <br />SEE "ROOF SHEATHING ATTACHMENT' <br />TABLE FOR FIELD SPACING <br />#8 2" DECK SCREWS E 6" S" O.C. MAX G <br />EDGES 8 12" O.C. MAX IN FIELD. UNTHREADED <br />SHANK TO EXTEND BEYOND THICKNESS OF <br />SUB -FLOOR SHEATHING <br />I YH. J/4" I #U SUB-NL WK ULUKINU ULULU I U ALL LAHUSLU MLMULKJ <br />'++ <br />.��A•A•A•dA•A•4s�•� j�.r� f�f.r�j.A•A•A•A•A�.�A•A•A•A•�T <br />A•A�AiA'I A•Ar©i�r©.+LAV� <br />AVA•ATAV4 I•A•A•A <br />• • <br />NN • <br />• • • <br />ROOF WIND DESIGN PRESSURES <br />1EGRDssI ABLE/ <br />z�a.mc <br />� eiawwu�GTe�Gom�. a� <br />uTelE�m.enNM <br />PResa,mE wEFNGENr..l.o.,s <br />FASTENER SCHEDULE <br />WINDOW AND <br />DOOR BUCK FASTENERS <br />FASTENER <br />APPLIGiICN <br />91g <br />ttFE <br />SPADING <br />REMARKS <br />APPLICATION <br />BITe <br />ttPE <br />BPAgN3 <br />REMARI6 <br />1M PT INNING 70 <br />MA80NRYICONC. <br />CASEHARDENEDCOIL <br />NbLl1/T LONG. <br />e•OC <br />OMAOE DOOR BUCK <br />TO IMBJIRV/VINO. <br />1M'tlA <br />NOWASHFR <br />TPPCON MASONRY <br />FASTENER <br />S� <br />11/1"EMBED., 1"ENotlSI, <br />I1Q•EIX3E DIeT <br />SOpIXT. DOORS <br />o <br />CABS HARpBIED LCA <br />0.OIC <br />WNpOYAWORl FABT@IED <br />MADE OOWI eLT( <br />OTO <br />3••tlA OR <br />E%PANeIONBOLT <br />01L (0/CW# <br />1•EMBED.. 1"ElDbST, <br />I , SEE NOlEB <br />NNL 11?LIXJG. <br />STAGGERED <br />MAS'INRYroONL <br />MABOMTroONG. <br />wI WA91@t <br />24"OE ItR Otnl <br />]•EDGE OISr <br />wHDOW— <br />CABEHbtDENEDCgL <br />I,.- <br />WINDOwmocal FASTe <br />METN-BTIWTO <br />CONTACT THIS ENGINEER <br />FOR SPACING <br />tv PT,3EENOTEe <br />tJNL 11IT LOYG. <br />9TAOGEREO <br />IMOMASLNRYIWNC. <br />.—.IC.- <br />REQUIREMENTS <br />EXT. SWINODOOR <br />(n 3ne•OV. <br />'TAPLOM <br />111T EMBED,B <br />NONBEAMNG WIbD <br />I- E%PM•ON 1'EMBED.1"END <br />]I" <br />Bl1CKSEENDTEe <br />NO WABHHi <br />FABTNEN <br />I80F <br />WST,11R'EDOEtlTT <br />WALL iO CONC.eVB <br />WI WASHHI BOLT 018T.,3•EOGEDL4F. <br />T PT'AwDOWBUtl( 01]B'PAFn]1R• e"OIC 1•E. DUST. It¢ <br />PT TO STEELgJl..BH W/WA91ER eTACA M EDOEpBT. <br />No Ee <br />NOTES <br />1. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS <br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURERS SPECS AND/OR NQA <br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED <br />4. RAF SHALL BE HILTI X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN <br />5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE <br />6. WINDOW AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXCEPT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. ix MEMBERS ARE NAILED AND <br />2% MEMBERS ARE SECURED W/ TAPCONS OR RAF TO THE SUBSTRATE. <br />GENERAL NOTES: <br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND <br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT <br />ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN <br />ON STRUCTURAL DRAW NGS. APPLICABLE BUILDING CODE STANDARDS: FBCR 2020, 7th EDITION <br />AO 318-14, BUILDING CODE REQUIREMENTS <br />FOR STRUCTURAL CONCRETE, THIS 4021602-18 AISI SPECIFICATION FOR THE DESIGN OF <br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2018, ASCE 7-16 AND AISC SPECIFICATIONS <br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE I WENDEDTO BE TYPICAL AND <br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, <br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN, <br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE <br />DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT <br />TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART <br />OF THE WORK. <br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORT NO AND STABLE AFTER THE BUILDING <br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND <br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS <br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, <br />TEMPORARY BRACING, GUYS OR TIE-OONN3. <br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION <br />REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. <br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C331C93M. MAXIMUM AGGREGATE SIZE SHALLBE3W. <br />WOOD: <br />PROVIDE 6%AIR ENTRAINED CONCRETE SPOSS) TO EARTH OR WEATHER NON -BEARING WOOD WALLS TOP PLATES S SIDS CAN BE SPF. <br />ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFERED 314'. ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING, <br />PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SIA&40N40ROUND WiM INDICATED ON <br />CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2 OR BETTER. Fb = 1100 PSI AND A MODULUS OF <br />ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE <br />DRAWINGS. SEAMS LAPPED 61NCHE8 AND 3EPl®WITHE9IVETAPE <br />PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES <br />SHALL BE RATEDTO RETENTION LEVELS OF 0.25 PCF OF A BORATE PRESERVATIVE TREATMEW: DISOOIUM <br />FORM -WORK: <br />CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY <br />FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, <br />REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED <br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI 347 LATEST <br />W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT <br />EDITION,'RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK. <br />CONTAINS MORE THAN W OF HEARTWOOD. <br />EXCLUSIONS FROM THESE PLANS: <br />MINIMUM NAILING PER FBOR 2020, 7th EDITION SEE NAILING SCHEDULE ON PLANS. <br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS <br />VIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER <br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURALDEPENDING PROVIDE <br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS, <br />SYP <br />UNTREATED WOOD SRALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED <br />WELDED WIRE MESH: <br />AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. <br />WELDED WARE MESH, SHALL BE ASTM A7064/Al064M. GRADE 65 AND BE PLACED IN ACCORDANCE WITH THE <br />WOOD TRUSSES: <br />ACI TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL <br />BE SUPPORTED WITH 2" CHAIRS SPACED T-O" OC, EACH WAY. <br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THENATIONAL DESIGN SPECIFICATIONS FOR <br />STRESS -GRADE LUMBER AND ITS FASTENINGS" BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS. <br />DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR REINFORCING STEEL: <br />TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. REBAR SHALL BE ASTM A815A815M GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM-15 <br />GRADE BO IN MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN ACCORDANCE <br />DESIGN LOAM: Wt THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS. <br />CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL <br />AND VERTICAL BARS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEER'S <br />ROOF: LIVE LOAD FLOOR: LIVELOAD 40 psf REVIEW. <br />20 psf TOP CHORD nonKo —rit TYR. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #6 BAR - 36" <br />10 psf BTM CHORD--nourleln #5 BAR - 30" #7 BAR - 47' <br />PROVIDE 36"x 36"CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR SEE DETAILS <br />DEAD LOAD DEAD LOAD FOR ADDITIONAL INFORMATION. <br />15 psf TOP CHORD 20 psf TOP CHORD <br />(7 psf W ASPHALT SHINGLES) (10 psf W/ No GYPCRETE) <br />10 pst BTM CHORD 5 psf BTM CHORD <br />DEAD LOAD TO RESIST WAND UPLIFT: 1Opsf <br />BALCONY LIVE LOAD 60 psf <br />STAIRS LIVE LOAD 40 psf <br />WIND DEAD LOAD SPEED =150 MPH 3-SECOND GUST <br />(ASCE 7.16 (FBC R2020) EXPOSURE B, RISK CATEGORY II) <br />LIVE LOADS: LIMNHASITABLE ATTIC WITHOUT STORAGE: 10pef, UNINHABITABLE ATTIC WITH LIMITED <br />STORAGE: 20psf, HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS. 30psf, BALCONIES (EXTERIOR) <br />AND DECKS: 40psf, GUARDS AND HANDRAILS: 200ps1, GUARD IN -FILL COMPONENTS: 50pV, PASSENGER <br />VEHICLE GARAGES: 50psf, ROOMS OTHER THAN SLEEPING ROOM: 40psf, SLEEPING ROOMS: 30psf, STAIRS: <br />40psf <br />SHOP DRAWING REVIEW: <br />SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT <br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY <br />COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. <br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT <br />DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM <br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036' AND BE MANUFACTURED FROM STEEL <br />MEETING THE REQUIREMENTS OF ASTM A446/A446M, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. <br />DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14, "DESIGN NATIONAL <br />STANDARDS FOR METAL-PLATECONNECTED-WOOD TRUSS CONSTRUCTION:, AND "SCSI LATEST EDITION' <br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED <br />WOOD TRUSSES. <br />TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF <br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR <br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WTH ANSI/ASCE 788: 1990. <br />ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS. <br />THICKENED SLAB BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH <br />MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT <br />WALL. TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. <br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES ANDARCUND CORNERS. DOWEL ROOF BFL LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED ASA GUIDE FOR BEARING <br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. <br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS <br />WITHOUT THE APPROVAL OF THE ENGINEER. <br />MASONRY: <br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE <br />"SPECIFICATION MASONRY STRUCTURES" CTMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY <br />STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS PUBLISHED BY <br />THE MASONRY STANDARDS JOINT COMMITTEE. <br />ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK <br />MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE Trn - 2000 PSI. BLOCK SWILL BE PLACED USING <br />RUNNING BOND UNLESS OTHERW SE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE <br />FLOOR <br />OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE PROHIBITED <br />PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH <br />WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER, IN ALL INSTANCES, THE CONTRACT <br />ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS <br />DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERWISE SPECIRED IN <br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3W <br />WRITING BY THE ARCHITECT. <br />COURSE AGGREGATE, AND SHALL BE PLACED W A SLUMP OF 8" TO 10". USE ONLY MECHANICAL VIBRATION <br />TO CONSOLIDATE GROUT. <br />FOUNDATION/ SITE PREPARATION' <br />TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE <br />FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PV,, FOOTING <br />PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS <br />EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95%OF THE <br />SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO <br />MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE W TH ASTM P7557. TREAT ALL <br />CELLS TO BE FILLED. <br />SOIL FOR TERMITE PROTECTION <br />FILL CMU CELLS SOUD WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL <br />THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY <br />REINFORCING. <br />SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE <br />GEO-TECHNICAL ENGINEERS REQUIREMENTS SHALL BE RECOMPACTED AND RETESTEDAT THE <br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O. <br />CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE <br />MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL <br />STRUCTURAL STEEL: <br />BE MADE BY THE GEO-TECH. ENGINEER. <br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE <br />CONCRETE" <br />SPEOFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, <br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM <br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: <br />A36/A36M, Fy • 36 kv FOR ANGLES, PLATES, AND WSHAPES. STRUCTURAL TUBING SHALL BE ASTM <br />A500/ASOOM, GRADE B, Fy = 48 ktl. STRUCTURAL PIPE SHALL BE ASTM A53/A53M, GRADE B, TYPE E OR S, Fy = <br />2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB ON -GRADE <br />35 ksi. TUBE AND PIPE COLUMNS SHALL BE CONCRETEFILLED IN THE SHOP. <br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURALTBWa SLAB. <br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL <br />CONTRACTOR 9IRPLL SUBMIT PROPoSEDMXOEBfYJS WITHHSTORICMSTRENGTHDATA FOR EACH SEPARATE MIX PPoORTO <br />STRENGTH <br />MITCONCRETE <br />EACH SEgZHt <br />OTHER BOLTS SHALL BE ASTM F3125IF3125M BOLTS VITH WASHERS UNDER THE TURNED ELEMENT. BOLTS <br />CONCRETE PLACEMENT. SLUMP SIDESIGN& IX� 5"M-PRIOR TO THE ADDITIONTAFOR <br />SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN-OFF-THENUT METHOD. <br />CONCRETE SHALL COM]LYWRHALL THE REQUIREMENTSOF ACI 318 AND ASTMC94IC94MOR MEASURING, MAW TPANWORONG <br />ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J4BOLTS ARE TO BE STEEL. <br />ETC. CONCRETE TICKETS SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN <br />WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSIT® IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES IF FORANY REASON <br />THERE IS A DENY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL <br />BE THE RESPONBBUTY OF THE TESTING LABORATORY TO NOTIFY THE OWNERS REPRESENTATIVE AND THE CONTRACTOR OF ANY <br />NON COMPLIANCE WITH THE ABOVE <br />REQUIRED CONCRETE COVERAGE OVER REBARSIILL BE AS FOLLOWS <br />A 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY E%PDSED TO EARTH FOUNDATVAS) <br />B FOR CONCRETE EXPOSED TO EARTH ANWORWEATHEt <br />1-117 FOR #5 AND SMPLLet <br />7 FOR #8 AND URGER <br />C. FOR CONCRETE NOT EXPOSED TO WEATHER <br />31C FOR SLABS WALLS AND JOISTS <br />1.1/2' FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS <br />DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL <br />LAYOUT, SPANS 8 ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT <br />AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIREDTO THE <br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL <br />PROVIDE ENGINEERED SHOP DRAW NGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION <br />PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA <br />LICENSED PROFESSIONAL ENGINEER. <br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDEDTO FACILITATE THE <br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS <br />PROVIDED BY THE TRUSS ENGINEER. <br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE <br />OF THE DELEGATED TRUSS ENGINEER. WIND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-16 COMPONENT <br />AND CLADDING WAND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR <br />ALL TRUSS TO TRUSS CONNECTIONS. <br />MOON <br />rou� <br />2 <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-77415078 <br />FAX: 407-7744078 <br />www.abdeafgngroup.00m <br />AA N: 0003325 <br />DRAFTING BY: <br />A.S. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 336M <br />PH: 813486-2628 <br />FAX: 813886-2802 <br />SILVERADO <br />LOT# 13 <br />BLK# 14 <br />DETAILS <br />12 <br />OCAIM 1/4"=1'-O" j <br />SN1 <br />