Laserfiche WebLink
w <br />r <br />dh <br />A <br />© TRIM NAIL <br />INSTALLED THROUGH <br />FASCIA @ 16" O.C. MA} <br />7O STAPLES INSTALLED <br />THRU SOFFIT AT NAIL <br />HEM AND IN VALLEYS <br />® FASC <br />DETAIL A <br />FASCIA <br />7D STAPLES INSTALLED @ <br />12" O.C. MAX (INTO <br />WOOD) IN J-CHANNEL <br />SLOT OR T-NAIL @ 12" <br />O.C. MAX. (INTO <br />CONCRETE/MASONRY) <br />*' MA <br />DETAIL D <br />J—CHANNEL <br />FASCIA <br />A WOOD <br />D BY OTHERS <br />BATTEN STRIP ANCHOR 12 <br />10d NAIL AT EACH <br />TRUSS/JOIST/ RAFTER <br />LOCATION NOT TO <br />EXCEED 24" O.C. INTO <br />FRAMING rTRUSS/JOIST/RAFTER <br />/ BY OTHER <br />72)STAPLES INSTALLED <br />2-1/4' <br />EMB. <br />THRU SOFFIT AND <br />1X2 WOOD BATTEN 11 <br />Jt <br />J-CHANNEL AT NAIL <br />HEM AND IN VALLEYS <br />1 <br />O <br />STAPLES INSTALLED @ <br />OFFIT 1O <br />12" O.C. MAX (INTO <br />IN J-CHANNEL <br />J-CHANNEL 3Q DETAIL B <br />O(7DWOOD) <br />SLOT MAX. <br />J—CHANNEL <br />FASCIA <br />12 BATTEN STRIP ANCHOR <br />r2X2 WOOD BATTEN 10 <br />10d NAIL AT EACH <br />TAPLES INSTALLED 77 <br />TRUSS/JOIST/ RAFTER <br />THRU SOFFIT AND <br />LOCATION NOT TO <br />J-CHANNEL AT NAIL HEM <br />EXCEED 24" O.C. INTO <br />AND IN VALLEYS <br />FRAMING <br />#8X3" WOOD SCREW OR <br />TAPPING SCREW, <br />BATTEN ATTACHMENT <br />O STAPLES INSTALLED <br />THRU SOFFIT AND <br />FASTENER SPACED 24" <br />J-CHANNEL AT NAIL <br />MAX. O.C. <br />HEM AND IN VALLEYS <br />J L `J-CHANNEL 3Q <br />O STAPLES INSTALLED <br />THRU SOFFITAND <br />J-CHANNEL AT NAIL <br />HEM AND IN VALLEYS <br />O SOFFIT <br />3D J-CHANNEL <br />J" A <br />DETAIL E <br />J—CHANNEL <br />TRUSS/FRAMING OVERHANG EAVE CONSTRUCTION <br />—SPAN'U—� 1•—SPAN'!,—� <br />SEE DETAIL'A' SEE DETAIL'E'—� + <br />EAVE CROSS-SECTION <br />SINGLE SPAN WN-CHANNEL <br />J-CHANNEL @ WALL, FASCIA @ FASCIA END <br />-EAVE WIDTH <br />(ROOF <br />OVERHANG) <br />CONCRETE; <br />CIVIL OR WOOD <br />(NOTEA) <br />#0FFr=rA. <br />SEE DETAIL'D' SEE DETAIL'E' <br />EAVE CROSS-SECTION <br />SINGLE SPAN WN-CHANNEL <br />J-CHANNEL @ WALL AND FASCIA END <br />O 11 1X2 WOOD BATTEN <br />r2X2 WOOD BATTEN 10 <br />/ O SOf <br />NSTALLATION SCREW, <br />BATTEN ATTCHMENT <br />FASTENER SPACED 24" g� <br />MAX O.C. <br />STAPLES INSTALLED @ <br />12" O.C. MAX (INTO <br />7D WOOD) IN J-CHANNEL <br />O ""'WOOD <br />LOT OR T-NAIL @ 12" <br />O.C. MAX. (INTO <br />CONCRETE/MASONRY) <br />CONCRETE/CMU OR <br />(NOTE 1) <br />Q J-CHANNEL <br />8 <br />nl=TAII r- <br />J-L;rlA VIVtL <br />TRUSSMOIST/RAFTER <br />BY OTHER <br />2-1/4" NSTALLATION SCREW, <br />EMB. BATTEN ATTCHMENT <br />FASTENER SPACED 24" 90 <br />MAX O.C. <br />STAPLES INSTALLED @ <br />12" O.C. MAX (INTO <br />O WOOD) IN J-CHANNEL <br />_ O SLOT OR T-NAIL @ 12" <br />O.C. MAX. (INTO <br />CONCRETE/MASONRY) <br />CONCRETE/CMU OR <br />WOOD (NOTE 1) <br />NOTE 1: MINIMUM SPRUCE -PINE -FIR <br />FRAMING OR CONCRETE/MASONRY. <br />BUILING CODE REQUIREMENTS FOR <br />SUBSTRATE MATERIAL MUST BE MET. <br />irsi=:i?i.:��••• <br />=.j..i 3.519 <br />EAVE WIDTH <br />•a:i; .375 .375 <br />(ROOF <br />�••i�::rii 49 3.625 3.625 3. <br />OVERHANG) <br />5 <br />\ <br />.08 .0 <br />12 <br />-CONCRETE; <br />��— <br />CMU OR WOOD <br />( NOTE A) <br />DETAIL A <br />12" TRIPLE 4 FULL-0-VENT SOFFIT ECO <br />VINYL -NO. 639 <br />1 <br />Groin <br />441 N. RONALD REAGAN BLYD <br />LONG WOOD, FL 32750 <br />PH: 407-7746078 <br />FAX: 407-7744078 <br />1 —DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 3" <br />PH: 813.8862828 <br />