Laserfiche WebLink
PREFORMED CONTROL JOINT <br />MA'*E OF CONTROL JOINTS TO <br />BE WRED TIED TO LATH • 9' . <br />OJC. MAX (VERT.) NOTE, DO <br />NOT FASTEN CONTROL JOINT TO <br />WAIL EVEN F STUD EXISTS <br />BEYOND EXCEPT STAPLES kill <br />SECT LBO JOMAY BE USEDNT TE1P. <br />DURING INSTALLATION —� <br />FASTENERS TO BE SPACED <br />• T Or—ERT MAX VERTICALLY <br />i, THIICIG 3 COAT CEMENT <br />PLASTER <br />\ W® LAYER 9, FORTFIEER <br />BUILDING PAPER <br />APPROVED PETAL LATH <br />FASTENED •T' (VERT.) Or— MAX <br />AT SUPPORT$ <br />IRS LAYER'L <br />STUCCO WRAP <br />)ROOD SWEATMING <br />LATH SMALL NOT BE CCNTNUOUS •• To .• .• ro r <br />TIRO" CONTROL no nL <br />JOINTS BUT SHALL \ <br />ISE STOPPED AC, <br />TIED AT EACH SIDE. PROVIDE 2X4 BLOB <br />PER A67M CI069 \ <br />PLACED PLAT MAX 6' TO S' <br />FROM CONTROL JOINT WEN <br />\ CONTROL JOINT FALLS ON <br />L FASTENERS FOR LATH TO BE NAILS, OR- i / STRUCTURAL STUD <br />STAPLES N COMPLIANCE UV ASTM CI063 T� <br />2. WIE TIE& TO BE (NO. 0) 00418' WIRE / <br />3. BLOCKING WON MAY BE N ADDITION <br />\ <br />TO WALL STCIS REQUIRED <br />�FPER <br />�yPLAN <br />O"M" TYPE CONTROL JOINT <br />—' 4NNaLE <br />Der E <br />OLroLD N611O •PT.♦ <br />®IOLG <br />O M. <br />A NWIC• <br />R.A <br />a. c1LEAee . n. e <br />1 c1.AUE . R.O <br />FCNANCALLY <br />IM {' OL MAIL <br />Ol IrOLD NMIm • R. A <br />1 CFEAGE • M. D <br />1 CRANE • FT. C <br />4 POl.D R.0 AMR R. <br />e rC R. C TOICJ!! <br />NO <br />euTTan <br />~ANX WTD! T. <br />LEAL TOLD, QQ <br />Imp. <br />3 COAT CEMENT <br />ORAMEl w• 2 COAT <br />ASTER 1Q <br />ER 9. FORTIFBER <br />PAPER aWA W ONLY) <br />ER L <br />ER.IPfN.APEO Y) <br />sTOF <br />roE <br />GL <br />NLAWen <br />KAS" on <br />s1= NITALL IOQ:= <br />NOTE, <br />APPROVED BUILDING IIRAP <br />SMALL BE LAPPED A MINIMUM OF <br />6' - VERTICAL LAPS (ROLL <br />ENDS) 4 6' • HORIZONTAL LAPS. <br />ALL SEAMS NEED TO BE TAPED <br />WTW FORTIDER 6WEATMNG TAPE <br />/ r r,N LA' • METaL Lan+ \ <br />.LAA1114 AT eOrTOM Q ROOF <br />WLL NIBLeEc,low <br />LATH VERTICAL LAP TO BE I' <br />IT METAL LATH <br />LLRD LAYER L <br />ST1C00 UIR.4P <br />' MN r .CP LOW OILY / I <br />UIRB LAYER 4, FGRTFlSER <br />\BUILDING PAPER / I <br />I <br />I <br />2 eGAPE.IIlJ'.1'-O' <br />VERTICAL LATH <br />Sc PAPER DETAIL <br />UCOD <br />NaE. $NEAT <br />SIDE LAP$ OF METAL <br />PLASTER BASES SMALL <br />BE SECURED TO dIILDi <br />FRAMW. MEMBERS. PAPEF <br />THEY SMALL BE TIED <br />WITM 00415-1k. (121-MF) BTCCJ <br />WIRE AT INTERVALS NOT <br />MORE THAN W (228-MM). <br />AS PER ASTM CV63. <br />Q KIC KO UTiwmr <br />F R REPAIR OF TEARS <br />"'RID LAYERS. TEARS <br />DETAIL <br />MAY Bfi PATCHED <br />UIRAP TAPE <br />PERU44OLISE <br />PER MAIM. SPEC. oR <br />PEEL 4 STICK <br />Li <br />j' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WAS LAYER 4, PORTFIIBER <br />BUILDING PAPER <br />WRB LAYER L <br />STUCCO LLRAP <br />INSTALL FASTENERS (CLIPS; <br />STRAPS. STAPLES) AS <br />REQUIRED TO SECURE <br />PIPE/ UIRE TO FRAMING <br />UM LAYER L <br />STUCCO ~ <br />URD LAYER -2 FORTFIBER <br />SUILDING PAPER <br />PETAL LATH <br />6'AW SELF -ADHERING MEMISRA 5 <br />FLASWNG OVER 4le4' <br />SELF -ADHERING MEMBRANE <br />FLASMNG OVER APPROVED <br />WDU6E WULAP. <br />RABLNR.Y. To EXTEND ONTO PIP@ <br />'4'A4' SELF-ADHERNCs MEMBRANE <br />FLASHING OVER APPROVED <br />MOUSE WR4P. <br />liABkNIdG TO EXTEND ONTO PIPE <br />V CONT. BEAD OF SEALANT <br />INSTALL APPROVED WOIIBEIRAP AIR <br />INFILTRATION BARRIER OVER <br />SFEATWNG <br />ELABTON£RIC COATING OVER STUCCO/ <br />C,V. FNBN (BEE TYP WALL SECTION) <br />SECTION PER TION MM <br />134ef1orl.UJg.W Pk WA m <br />EH•dw usa of pmtland combo[ pgatx <br />shag mmply wit, theASTM <br />aP 926-1 <br />r•quirem•nls of ASTM C 928-iSC. <br />IrrebllaUon of •Wdor Iht,ing and frarrnrig <br />sh•A comply wit, ASTM C 1063-19a, <br />or ASTM 1787. <br />4SL4' SELF-ADiERIYa MEMBRANE l <br />FLASHING (COMPATIBLE UV HORSE <br />WRAP MATERIAL) OVER \ <br />I. OR LESS PPE <br />PENETRATION .. <br />CUT AND OVERLAP ONE SIDE OFF <br />SELF -ADHERING MEMRANE <br />FLASMU4G <br />STEP e1 <br />WOOD SHEATHING <br />OR CMU <br />WRB LAYER N, <br />STUCCO WRAP (FRAME ONLY) <br />J' THICK, 3 COAT CEMENT <br />PLASTER (FRAME), 1/2' 2 COAT <br />CEMENT PLASTER (CMU) <br />METAL LATH (FRAME ONLY) <br />LAP WRIS 4 TAPE OVER <br />ROOF/WALL SCREED <br />5'X5' 'L' TYPE CONTINUOUS <br />GALV. METAL FLASHING <br />(NAIL TO ROOF DECK, NOT <br />WALL SHEATHINCs) <br />CAP SHINGLE - DO NOT NAIL, <br />INSTALL WITH ROOF CEMENT <br />ROOF PER ELEVATIONS <br />O"L" FLASHING <br />N.T.S. <br />PIPE <br />N.T.S. <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LATER #1, 5TUGGO WRAP) <br />WRB LATER #2 (FORTIFIBER <br />BUILDING PAPER) <br />METAL LATH <br />STUCCO <br />W xW SELF -ADHERING ME'BRAN E <br />FLASHING (COMPATIBLE W) WOUSE <br />WRAP MATERIAL) OVER 4'x4' <br />SELF -ADHERING. MEMBRANE <br />FLABHRJG OVER APPROVED <br />WOUBE WRAP, <br />FLASHING TO EXTEND ONTO FNF£ <br />CUT AND OVERLAP ONE SIDE OF <br />SELF -ADHERING MEMBRANE <br />FL46NNG <br />x—x—x—x <br />WOOD OR-1/16'l ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R"703.11 / ASTM G-84l-14a, MIN, 2.5 L55. <br />PER 5Q. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL32750 <br />PH: 407-7746078 <br />FAX: 407-774-4078 <br />www,abdesigngroup.com <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SURE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813S86-2828 <br />FAX: 813-88fr2802 <br />SUDDIV. & I.OT: <br />SILVERADO <br />LOT #4 <br />BLK 15 <br />PROJECT# <br />79. 1- 45 <br />MODEL <br />2795-CAMDEN <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />%Q50 MPH A B <br />I <br />DA1='E• 03/03/21 <br />SCALE: 1/4.=11—C <br />SHEET <br />WA1 <br />