7312 Steer Blade Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7312 Steer Blade Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:49:32 PM
Creation date
2/19/2025 11:26:32 AM
Metadata
Fields
Template:
Building Plans
Street #
7312
Location
Steer Blade Dr
Contractor
DR Horton
Building Plans - Permit #
2065
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL V SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE: <br />I. BOTTOM. 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />�:...� <br />• <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />I - <br />TOOLED 80 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />' <br />JOINTS AND INTERSECTIONS <br />' 1. <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, Y1 CAULKING • JOINT <br />I <br />I <br />ALL AROUND <br />I I <br />PER SECTION R703.7 <br />Exterior kMhv and plashvft <br />BACKER ROD <br />Exterior use of pordand cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />I <br />X� <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />orASTM 1787. <br />WRB LAYER M, <br />STUCCO WRAP <br />I` <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />UJRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />r <br />SHEATHINGAYER h,IF15ER <br />ING PAPER <br />wooD <br />coNBrucnoN <br />—METAL LATH <br />8. OJ'AJ VINYL CASING BEAD <br />6' RAISED BAND <br />V To A• tma:WALL w-eean <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCKA <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — — — • — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-541-14a, MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />W SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHINCs <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />GONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROIXsH / <br />WALLi <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />�A__VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />' `ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />Ys' TO X' MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />j__v I s, WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />)R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />::O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER <br />STUCCO WR< <br />WOOD SHEATHING <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE '0' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEiATHIM <br />LAYER 'I, <br />STUCCO WRAP <br />LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />WOOD CONSTRUCTION FINISH 4 WOODD <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • T' OG MAX <br />8, CM! <br />x• TO A• MID -WALL <br />WEEP SCREED <br />E? <br />6' WIDE STRP SELF <br />ADHESIVE FLASHING, CLEAN <br />... MASONRY BEFORE APPLYING <br />V FINISH • MASONRY <br />7B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCKI <br />S' <br />WRB LAYER h, <br />STUCCO WRAP <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.Y. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />1°hlf 1, <br />STEP 05 STEP #ro <br />OD <br />ELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-774-6078 <br />FAX 407-7744078 <br />www.abdesigngroup.com <br />AA #: OD03325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813886-2628 <br />FAX: 813-SM2802 <br />Btmz) . & L/OT <br />SILVERADO <br />LOT #4 <br />BLK 15 <br />PROJECT► <br />03719.001-04151 <br />HODEic <br />2795—CAMDEN <br />GARAGE BVWG: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 PH EXP. B <br />D 03/03/21 <br />SCALE: 1/4"=1'— 0" <br />SHEET <br />WA2 <br />