I I IP 1[ ni -I -. --I _ I I 1 - - ' I ' ! ! - I 1 - 'W I `I L <br />LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING HEIGHT <br />LIGHTING <br />5 <br />DESIGNATES FIXTURE TYPE - SEE LIGHTING FIXTURE SCHEDULE <br />NORMAL BRANCH SURFACE, SUSPENDED, OR RECESSED FIXTURE <br />(TYPE DETERMINES MOUNTING) <br />® <br />CRITICAL OR EQUIPMENT BRANCH SURFACE, SUSPENDED, OR RECESSED <br />FIXTURE (TYPE DETERMINES MOUNTING) <br />® <br />LIFE -SAFETY BRANCH SURFACE, SUSPENDED, OR RECESSED FIXTURE <br />(TYPE DETERMINES MOUNTING) <br />O <br />NORMAL BRANCH SURFACE, SUSPENDED, OR RECESSED FIXTURE <br />(TYPE DETERMINES MOUNTING) <br />® <br />® <br />CRITICAL OR EQUIPMENT BRANCH SURFACE, SUSPENDED, OR RECESSED <br />FIXTURE (TYPE DETERMINES MOUNTING) <br />® <br />0 <br />LIFE -SAFETY BRANCH SURFACE, SUSPENDED, OR RECESSED FIXTURE <br />(TYPE DETERMINES MOUNTING) <br />® <br />NORMAL BRANCH SURFACE, SUSPENDED, OR RECESSED FIXTURE <br />(TYPE DETERMINES MOUNTING) <br />® <br />CRITICAL OR EQUIPMENT BRANCH SURFACE, SUSPENDED, OR RECESSED <br />FIXTURE (TYPE DETERMINES MOUNTING) <br />® <br />LIFE -SAFETY BRANCH SURFACE, SUSPENDED, OR RECESSED FIXTURE <br />(TYPE DETERMINES MOUNTING) <br />Q <br />NORMAL BRANCH WALL BRACKET FIXTURE <br />CRITICAL OR EQUIPMENT BRANCH WALL BRACKET FIXTURE <br />LIFE -SAFETY BRANCH WALL BRACKET FIXTURE <br />®� <br />EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED <br />ON PLANS <br />POWER - RECEPTACLES <br />120V. DUPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE <br />1'-6" <br />ABBREVIATIONS FOR EXCEPTIONS) <br />AFF TO CL. <br />120V. DUPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT <br />AS NOTED OR <br />(REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) <br />SEE SPECS <br />120V. QUADPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE <br />1'-6" <br />ABBREVIATIONS FOR EXCEPTIONS) <br />AFF TO CL. <br />120V. QUADPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT <br />AS NOTED OR <br />(REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) <br />SEE SPECS <br />120V. GFI RECEPTACLE - IVORY <br />1 <br />AFF TO CL. <br />120V. GFI RECEPTACLE - IVORY (SPECIAL MOUNTING HEIGHT) <br />AS NOTED OR <br />SEE SPECS <br />120V. DUPLEX RECEPTACLE - CRITICAL, RED (REFER TO <br />V-6" <br />RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) <br />AFF TO CL. <br />a <br />120V. DUPLEX RECEPTACLE - CRITICAL, RED - SPECIAL MOUNTING <br />AS NOTED OR <br />HEIGHT (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) <br />SEE SPECS <br />120V. QUADPLEX RECEPTACLE - CRITICAL, RED (REFER TO <br />11-6. <br />RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) <br />AFF TO CL. <br />120V. QUADPLEX RECEPTACLE - CRITICAL, RED - SPECIAL MOUNTING <br />AS NOTED OR <br />HEIGHT (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) <br />SEE SPECS <br />120V. GFI RECEPTACLE - CRITICAL, RED <br />1 <br />AFF TO CL. <br />120V. GFI RECEPTACLE - CRITICAL, RED (SPECIAL MOUNTING HEIGHT) <br />AS NOTED OR <br />SEE SPECS <br />SINGLE RECEPTACLE (TYPE AS NOTED ON PLANS) <br />1'-6" <br />(REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) <br />AFF TO CL <br />SINGLE RECEPTACLE- CRITICAL, RED- (TYPE AS NOTED ON PLANS) <br />1'-6" <br />(REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) <br />AFF TO CL <br />LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING HEIGHT <br />FIRE ALARM <br />Q <br />FIRE ALARM VISUAL STATION - LIGHT ONLY <br />FIRE ALARM AUDIO DEVICE WITH STROBE <br />FIRE ALARM HORN WITH STROBE <br />F❑ <br />FIRE ALARM MANUAL PULL STATION <br />0 <br />FIRE ALARM SMOKE DETECTOR <br />O <br />HEAT DETECTOR <br />FAC <br />FIRE ALARM CONTROL PANEL <br />FAAP <br />FIRE ALARM ANNUNCIATOR PANEL <br />FEP <br />FIRE ALARM EXTENDER PANEL <br />MISCELLANEOUS <br />q= <br />NON -FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING/POLES) <br />FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING/POLES) <br />`® <br />COMBINATION MOTOR STARTER <br />Ea3 <br />FACTORY WIRED CONTROLLER OR EQUIPMENT <br />MOTOR CONNECTION <br />DUCT HEATER CONNECTION <br />JUNCTION BOX <br />�C Q C <br />SECURITY CCTV CAMERA <br />1! <br />PANELBOARD - FLUSH MOUNTED <br />PANELBOARD- SURFACE MOUNTED <br />DS <br />DOOR SWITCH - X- RAY EQUIPMENT FOR SHUT DOWN <br />FE-C-B-1 <br />ELECTRONIC CIRCUIT BREAKER <br />TVSS <br />TRANSIENT VOLTAGE SURGE SUPPRESSORS <br />PDC I <br />POWER DISTRUBITION CABINET AND UPS <br />SWITCHES <br />NORMAL <br />CRITICAL <br />S <br />�' <br />SINGLE POLE SWITCH <br />3'-10" <br />AFF TO CL <br />S2 <br />$2 <br />DOUBLE POLE SWITCH - CENTER OFF <br />T-10" <br />AFF TO CL <br />S3 <br />$3 <br />THREE WAY SWITCH <br />S-10" <br />AFF TO CL <br />S4 <br />$4 <br />FOUR WAY SWITCH <br />3'-10"AFF TO CL <br />PUSH BUTTON SWITCH (MUSHROOM BUTTON) <br />S-10" <br />AFF TO CL <br />RACEWAY <br />CONDUIT & BRANCH CIRCUIT WIRING <br />BRANCH CIRCUIT RACEWAY CONCEALED IN OR BELOW FLOOR SLAB OR <br />BELOW GRADE <br />FEEDER RACEWAY CONCEALED IN OR BELOW FLOOR SLAB OR BELOW <br />GRADE <br />------- <br />EXPOSED CONDUIT & BRANCH CIRCUIT WIRING <br />�-o <br />RACEWAY TURNING UP AS VIEWED FROM THE LOAD <br />RACEWAY TURNING DOWN AS VIEWED FROM THE LOAD <br />RACEWAY VERTICAL RISER WITH HORIZONTAL CONTINUATION AT TWO <br />LEVELS SHOWN <br />CAPPED RACEWAY <br />CIRCUIT CONTINUATION <br />HOMERUN TO PANELBOARD - NUMBER OF ARROWHEADS INDICATES <br />NUMBER OF #12 AWG PHASE CONDUCTORS. FOR MINIMUM CONDUIT <br />REFER TO SPECIFICATION. <br />NOTES: <br />1. #12 AWG NEUTRAL CONDUCTOR, ALTHOUGH NOT INDICATED, <br />SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. <br />2. #12 AWG GREEN GROUND CONDUCTOR, ALTHOUGH NOT INDICATED, <br />SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. <br />3. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF <br />THREE BRANCH CIRCUITS. PROVIDE A SEPARATE NEUTRAL <br />CONDUCTOR WITH EACH PHASE CONDUCTOR FOR ALL <br />BRANCH CIRCUITS. <br />LEGEND (NOT ALL SYMBOLS <br />MAY BE USED) <br />SYMBOLF <br />I DESCRIPTION <br />MOUNTING HEIGHT <br />TO CENTER LINE <br />VOICE/DATA <br />Q X <br />DATA OUTLET <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />18" AFF OR MATCH POWER <br />OUTLET <br />X <br />VOICE / DATA OUTLET <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />18" AFF OR MATCH POWER <br />OUTLET <br />a'X <br />DATA OUTLET (SPECIAL MOUNTING HEIGHT) <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />SMH AS NOTED, OR PER <br />ARCH. ELEVATIONS <br />.'X <br />VOICE / DATA OUTLET (SPECIAL MOUNTING HEIGHT) <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />SMH AS NOTED, OR PER <br />ARCH. ELEVATIONS <br />®X <br />DATA OUTLET (FLOOR OR BELOW FLOOR) <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />FLUSH FLOOR OR SURFACE <br />MOUNT BOX <br />®X <br />DATA OUTLET (CEILING - FLUSH OR ABOVE CEILING) <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />FLUSH CEILING OR ABOVE <br />CEILING (AC) <br />®X <br />VOICE / DATA OUTLET (FLOOR - FLUSH OR BELOW FLOOR) <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />FLUSH FLOOR OR SURFACE <br />MOUNT BOX <br />®X <br />VOICE / DATA OUTLET (CEILING - FLUSH OR ABOVE CEILING) <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />FLUSH CEILING OR ABOVE <br />CEILING (AC) <br />a X <br />VOICE OUTLET (FLOOR - FLUSH OR BELOW FLOOR) <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />FLUSH FLOOR OR SURFACE <br />MOUNT BOX <br />®X <br />VOICE OUTLET (CEILING - FLUSH OR ABOVE CEILING) <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />FLUSH CEILING OR ABOVE <br />CEILING (AC) <br />X <br />WIRELESS ACCESS POINT CONNECTION <br />(SUB -SCRIPT REPRESENTS NUMBER OF OUTLETS IN FACEPLATE) <br />WALL, CEILING, OR ABOVE <br />CEILING <br />D <br />DISTRIBUTED ANTENNA SYSTEM (DAS) <br />WALL, CEILING, OR ABOVE <br />CEILING <br />0- <br />TELEMETRY ANTENNA <br />CEILING OR ABOVE CEILING <br />VOICE OUTLET <br />+54" AFF OR PER ARCH. <br />ELEVATIONS <br />VOICE OUTLET (SMH) <br />+34" AFF OR PER ARCH. <br />ELEVATIONS <br />W <br />WALL PHONE VOICE OUTLET <br />+54" AFF OR PER ARCH.ELEVATIONS <br />CT==e, rr7--= <br />TELECOMMUNICATIONS GROUNDING BAR (ELEVATION VIEW) <br />PROVIDED BY DIVISION 26. <br />WALL MOUNTED OR AS <br />VENDOR SPECIFIED <br />aTA <br />DATA OUTLET (SPECIAL MOUNTING HEIGHT) <br />(TIME AND ATTENDANCE) <br />SMH AS NOTED, OR PER <br />ARCH. ELEVATIONS <br />aEWB <br />ELECTRONIC WHITE BOARD <br />SMH AS NOTED, OR PER <br />ARCH. ELEVATIONS <br />LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING HEIGHT <br />ABBREVIATIONS <br />ABC <br />ABOVE COUNTER <br />ADO <br />AUTOMATIC DOOR OPENER <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />COF <br />COFFEE MACHINE <br />CLG <br />CEILING <br />EWB <br />ELECTRONIC WHITE BOARD <br />EQ <br />EQUIPMENT SYSTEM <br />EWC <br />ELECTRIC WATER COOLER <br />FBO <br />FURNISHED BY OTHERS <br />FI <br />FILM ILLUMINATOR (VIEW BOX) <br />FLR <br />RECESSED FLUSH IN THE FLOOR <br />ICE <br />ICE MACHINE/MAKER <br />IG <br />ISOLATED GROUND <br />LS <br />LIFE SAFETY BRANCH <br />C <br />CRITICAL BRANCH <br />MW <br />MICROWAVE <br />REF <br />REFRIGERATOR <br />PRN <br />PRINTER <br />SMH <br />SPECIAL MOUNTING HEIGHT - AS NOTED OR SEE SPECS <br />TYP <br />TYPICAL INSTANCE <br />TV <br />TELEVISION <br />UR <br />UNDERCOUNTER REFRIGERATOR <br />WP <br />WEATHERPROOF <br />EF <br />EXHAUST FAN <br />INDOOR AIR QUALITY NOTES <br />1. CONTRACTOR SHALL OBTAIN FROM THE OWNER A COPY OF THE INFECTION CONTROL RISK <br />ASSESSMENT (ICRA) PREPARED FOR THIS PROJECT. CONTRACTOR SHALL REVIEW THE <br />REQUIREMENTS IN THE REPORT AND PERFORM ALL WORK IN ACCORDANCE WITH THOSE <br />REQUIREMENTS. CONTRACTOR SHALL STRICTLY ADHERE TO THE LIMITS OF CONSTRUCTION <br />AREA, AND WHERE PHASING APPLIES SHALL ADHERE TO THE PHASING PLAN. ANY WORK <br />OUTSIDE THE CONSTRUCTION AREA SHALL BE COORDINATED WITH THE OWNER AND <br />PERFORMED IN ACCORDANCE WITH THE ICRA REPORT, UNDER THE SUPERVISION OF THE <br />OWNER'S REPRESENTATIVE OR OTHER DESIGNATED ICRA COMMITTEE OFFICER. <br />2. TO THE EXTENT THAT IT IS REQUIRED BY THE ICRA, THE CONTRACTOR SHALL ENDEAVOR <br />TO MAINTAIN EXISTING LEVELS OF INDOOR AIR QUALITY IN AREAS SURROUNDING AND <br />ADJACENT TO THE CONSTRUCTION WORK ZONE, AND ELSEWHERE IN THE FACILITY. <br />IT SHOULD BE ANTICIPATED THAT THE ICRA REPORT WILL REQUIRE MEASURES TO THIS EFFECT <br />INCLUDING ERECTION OF CONSTRUCTION ZONE BARRIERS AND PROVISION OF NEGATIVE AIR <br />PRESSURE IN THE CONSTRUCTION ZONE RELATIVE TO OTHER AREAS OF THE NEW FACILITY. <br />3. IN ADDITION TO MEETING THE REQUIREMENTS OF THE ICRA REPORT, THE CONTRACTOR AT A <br />MINIMUM SHALL PROVIDE EQUIPMENT AND COMPONENTS NECESSARY TO CREATE A NEGATIVE <br />PRESSURE IN THE CONSTRUCTION WORK ZONE RELATIVE TO ADJACENT AREA. EXISTING HVAC <br />SYSTEMS AND COMPONENTS SHALL NOT BE USED FOR THIS FUNCTION, UNLESS SPECIFICALLY <br />APPROVED BY THE OWNER'S INFECTION CONTROL OFFICER. THE CONCEPT AND ALL ASPECTS <br />OF THIS WORK SHALL BE DONE IN ACCORDANCE WITH THE ICRA REQUIREMENTS AND AT A <br />MINIMUM AS FOLLOWS: <br />A. VERIFY ALL EXISTING WORK WHICH PASSES THROUGH THE CONSTRUCTION ZONE, AND IS <br />TO REMAIN, IS SEALED AND PROTECTED DURING THE CONSTRUCTION DURATION. <br />B. AIR REMOVED FROM THE CONSTRUCTION ZONE SHALL BE FILTERED AND/OR DISCHARGED <br />AS DIRECTED BY THE ICRA REPORT. <br />C. PRESENT THE NEGATIVE AIR PRESSURE PLAN TO THE OWNER FOR APPROVAL BY THE <br />INFECTION CONTROL COMMITTEE. <br />D. PROVIDE MEANS TO MONITOR AND VERIFY NEGATIVE PRESSURE IS BEING MAINTAINED IN <br />ACCORDANCE WITH THE ICRA REPORT, AND PROVIDE DOCUMENTATION TO THE OWNER AS <br />REQUIRED. <br />4. COORDINATE IN ADVANCE ANY REQUIRED EQUIPMENT SHUTDOWN WITH THE OWNER, AND <br />VERIFY BEFORE SHUTDOWN THAT EXISTING OR DESIRED AIR PRESSURE RELATIONSHIPS <br />WILL NOT BE ADVERSELY AFFECTED. <br />5. CONTRACTOR SHALL ENSURE THAT THE EQUIPMENT AND COMPONENTS NECESSARY TO <br />CREATE NEGATIVE AIR PRESSURE IN THE CONSTRUCTION WORK ZONE ARE CONNECTED <br />TO EMERGENCY POWER. (LIFE SAFETY CIRCUITS SHALL NOT BE USED.) <br />GENERAL CONSTRUCTION NOTES <br />1. PROVIDE TYPED DIRECTORY CARDS UNDER PLASTIC DOORS OF BRANCH CIRCUIT PANELBOARDS NEW AND <br />EXISTING AFFECTED UNDER THE SCOPE OF THIS PROJECT. DIRECTORIES SHALL INDICATE DEVICES BEING <br />SERVED INCLUDING SPACE NUMBERS IN WHICH DEVICES OR FIXTURES ARE LOCATED. SPACE NAMES AND <br />NUMBERS SHALL MATCH THE GRAPHICS INSTALLED IF DIFFERENT FROM THE SPACE NAMES AND NUMBERS <br />ON THE DRAWINGS. <br />2. REFER TO ARCHITECTURAL PLANS FOR RATED WALLS AND UL LISTED FIRE RATED DETAILS. <br />3. REFER TO THE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL DESIGN STANDARDS. THE ELECTRICAL <br />SPECIFICATIONS ARE A BINDING PART OF THE CONSTRUCTION DOCUMENTS. <br />4. ALL NEW AND EXISTING SWITCHES AND RECEPTACLES (EMERGENCY AND NORMAL) WITHIN THE PROJECT <br />LIMITS SHALL BE PROVIDED WITH ENGRAVED FACEPLATES TO MATCH EXISTING. VERIFY THAT EXISTING <br />FACEPLATES WITH CIRCUIT IDENTIFICATIONS ARE ACCURATE. PROVIDE NEW ENGRAVED FACEPLATES WITH <br />CORRECT CIRCUIT NUMBER AS NECESSARY. <br />5. PROVIDE CODE COMPLIANT PENETRATIONS FOR ALL NEW CONDUITS ENTERING/EXITING FIRE RATED <br />WALLS, <br />REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL FIRE RATED WALLS AND UL LISTED FIRE RATED <br />DETAILS. ALL EXISTING NON -CODE COMPLIANT ELECTRICAL PENETRATIONS WITHIN THE PROJECT SCOPE <br />(INCLUDING BUT NOT LIMITED TO EXISTING ELECTRICAL ROOMS, AND CORRIDORS) SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR TO CORRECT. <br />6. REMOVE AND RE -INSTALL ANY LIGHT FIXTURES OR CEILING MOUNTED DEVICES THAT NEED TO BE <br />TEMPORARILY REMOVED, DUE TO THE RENOVATION OF ANY MECHANICAL AND ELECTRICAL SYSTEMS. <br />VERIFY ALL AREAS OF POTENTIAL CEILING RE -WORK PRIOR TO BID. <br />7. MAINTAIN EXISTING FIRE ALARM SYSTEM WITHIN AREA OF DEMOLITION THROUGHOUT CONSTRUCTION <br />PERIOD. PROVIDE SMOKE DETECTORS COVERS DURING WORK HOURS. REMOVE SMOKE DETECTOR COVERS <br />OUTSIDE OF WORK HOURS. <br />8. VISIT THE SITE PRIOR TO BID AND ALLOW FOR EXISTING CONDITIONS IN HIS BID. MATCH THE EXISTING <br />COLOR SCHEME OF ELECTRICAL DEVICES ALREADY ESTABLISHED ON SITE AND CONFIRM WITH OWNER. <br />9. VERIFY EXISTING RECEPTACLES AND LIGHTS TO REMAIN ARE WIRED PER NEC REQUIREMENTS. RECTIFY <br />ALL EXISTING CODE VIOLATIONS WITH IN THE PROJECT LIMITS. <br />10 REFER TO MECHANICAL PLANS FOR EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS AS WELL AS <br />MOTOR SIZE, VOLTAGE, AND LOCATION. <br />11. ALL BRANCH CIRCUITS HOMERUN CONDUITS WITH THE CEILING SPACE COMPLETE TO THE PANELBOARDS <br />SHALL BE EMT CONDUIT. METAL CLAD (TYPE MC) CABLE OR ARMORED (TYPE AC) CABLE MAY BE UTILIZED ON <br />LIEU OF BRANCH CIRCUIT EMT CONDUIT, MC CABLE AND AC CABLE. THE CONDUIT OR METAL SHEATH SHALL <br />ITSELF QUALIFY AS A EQUIPMENT GROUNDING RETURN PATH IN ACCORDANCE WITH NEC. 250,118. <br />12. FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOXES TO RECESSED LIGHTING FIXTURES, 6 FT. <br />IN LENGTH. <br />CURRENT CODE REQUIREMENTS <br />NFPA 70: NATIONAL ELECTRICAL CODE (2011) <br />NFPA 72: NATIONAL FIRE ALARM CODE (2010) <br />NFPA 90B: STANDARD FOR THE INSTALLATION OF WARM AIR HEATING & <br />AIR-CONDITIONING SYSTEMS (2012) <br />NFPA 101: LIFE SAFETY CODE (2012) <br />NFPA 101A: LIFE SAFETY CODE (2010) <br />NFPA 241: STANDARD FOR SAFEGUARDING BUILDING CONSTUCTION AND <br />DEMOLITION OPERATIONS (2009) <br />FLORIDA BUILDING CODE: (2014) <br />FGI GUIDELINES: (2010) <br />ELECTRICAL SHEET INDEX <br />NUMBER <br />SHEET NAME SHEET NAME <br />E001 <br />ELECTRICAL LEGEND, NOTES, & SHEET INDEX <br />E002 <br />ELECTRICAL SPECIFICATIONS <br />E003 <br />ELECTRICAL SPECIFICATIONS <br />E201 <br />ELECTRICAL PARTIAL FLOOR PLAN - DEMOLITION <br />E301 <br />ELECTRICAL PARTIAL FLOOR PLAN - NEW CONSTRUCTION <br />E401 <br />ELECTRICAL RISER DIAGRAM & PANEL SCHEDULES <br />E501 <br />ELECTRICAL DETAILS <br />S aL]LtC O , ILEC <br />AA 26001479 <br />Sheet Notes: <br />Smith <br />Seckman <br />SRReid, Inc. <br />301 North Cattlemen Road, Suite 300 <br />Sarasota, FL 34232 <br />(941) 907-7750 <br />FAX: (941) 907-7751 <br />www.ssr-inc.com <br />Firm Certification - CA-0000857 <br />SSR# 1636044.0 <br />Erick Phelps - PE #64598 <br />Christopher E. Durham - PE #76655 <br />�oQ\o E D W 4RoO <br />ENS F'• l/,P�� <br />.� <br />No. 76655 <br />Ir= <br />• �: <br />STATE OF �44/` <br />Christopher Edward Durham <br />PE License No. 76655 <br />F "RIDACAN"ER <br />1M A <br />Research <br />Key Plan <br />MARK ISSUE DATE DESCRIPTION <br />Issue Log <br />CONSTRUCTION <br />DOCUMENTS <br />FLORIDA CANCER SPECIALISTS <br />EQUIPMENT REPLACEMENT <br />38010 MEDICAL CENTER AVE. <br />ZEPHYRHILLS, FL 33540 <br />Drawing Title <br />ELECTRICAL LEGEND, <br />NOTES, & SHEET INDEX <br />71604 <br />06 /29 /2016 <br />Scale <br />Sheet Number <br />E001 <br />Drawn By KDS <br />Approved By MLG <br />Filename <br />SaltCo, LLC 2007 <br />