Laserfiche WebLink
BUILDING CODE ANALYSIS <br />IIR <br />Weight <br />Machine <br />� U <br />L U N <br />U � � <br />m <br />Wei ht Rack I <br />1. <br />I <br />I <br />Weight <br />Machine <br />Weight <br />Machine <br />Weight <br />Machine L4 <br />Office <br />l59 <br />Asses, <br />StorDe157 <br />E58i LLP <br />Weight I I Weight I I Weight <br />Machine Machine Machine <br />Weight Weight Weight <br />Machine Machine Machine <br />Tec14s <br />156 <br />Weight Weight Weight a a a a o a <br />Machine Machine Machine = — � _ _ <br />o �� <br />32' <br />SYMBOL LEGEND <br />• F.E. <br />FIRE EXTINGUISHER <br />F.E.C. <br />FIRE EXTINGUISHER CABINET <br />® <br />MAGNETIC DOOR HOLDER <br />�S <br />SMOKE DETECTOR <br />�H <br />HEAT DETECTOR <br />® <br />FIRE ALARM PULL STATION <br />S♦ <br />STROBE <br />HIS 0--* <br />HORN AND STROBE <br />39 <br />EXIT LIGHTS <br />1 3K <br />EXIT LIGHTS WITH DIRECTIONAL ARROW(s) <br />EXIT WIDTH IN INCHES <br />125' <br />INTERIOR EXIT. PATH AND DISTANCE <br />A <br />SMOKE COMPARTMENT DESIGNATION <br />0 <br />— — -1 Women's <br />rI Locker <br />>: 155a <br />Sauna <br />I t II I II 11 <br />II II � I II !I <br />I LAa o L A J tI LJO O LAa I <br />Corridor <br />lob <br />VV <br />32' <br />E <br />Men's <br />154 <br />unc <br />Office <br />10 <br />�y <br />Hoorn -� <br />/52 <br />Dressing Watt <br />113A 11 <br />Corridor <br />111 <br />r <br />I <br />E <br />32' <br />lal <br />Mass <br />114 <br />Kitchen/ <br />Education <br />144ir <br />0 <br />• � II <br />Office v 143 �� \ <br />142 I • — <br />I <br />LIFE SAFETY PLAN <br />118'=I'-0' <br />I. Codes In effect: <br />Florida Building Code 2010 Florida Building Code <br />NFPA 101 2012 Edition <br />Florida Fire Prevention Code 5th Edition <br />2. Use and Occupancy Classification: <br />Building is non-seperoted <br />mixed occupancy Group <br />As per FBC Chapter 3 and NFPA 101 <br />'B' Business and Group 'A-3' <br />Assembly per FBC <br />508.3 and Life <br />Safety Code <br />6.1.14.1.10) <br />J. Type of Construction: <br />As per FBC Section 602 and NFPA l01 Table A.8,2.1.2 <br />Type I11B, Not Sprinklered or <br />NFPA Type Ill (2,0,0) <br />4. Allowable Height & Building Areas <br />Permitted <br />Existing <br />As per FBC Table 503 and NFPA 101(If applicable) <br />Building Height: <br />55' <br />22, <br />Number of Stories: <br />2 <br />1 <br />Building Area: <br />9,500 SF <br />13,570 SF <br />Refer area Increase calculation <br />Area of Remodeling: <br />--- <br />13,570 SF <br />Area Increase as per Section 506: <br />Rllll SING AREA MODIFICATIONS <br />--- <br />--- <br />Frontage Increase <br />If = fF/P-0.251 x W/30 <br />If = 15881588 - 0.251 x 20130 <br />If = l0.751 x 0.66 <br />If = 49X <br />Area Modification Calculations <br />Aa = At - [At x If] • [At x Is/1001 <br />Aa = 9,500 • 19,500 x 0.491 <br />Aa = 9,500 • 14,6551 <br />Aa = 14,155 SF. per floor > 13,570 SF. OK. <br />5. Fire Protection <br />Required <br />Existing/ <br />Desion <br />As per FBC Tables 601 & 602 <br />Proposed <br />and NFPA 101 (If app.) <br />Structural Frame <br />Including columns, girders, trusses: <br />0 <br />0 <br />--- <br />Bearing Walls <br />Exterior: <br />2 <br />2 <br />FBC Table 21.3.2 <br />Interior: <br />0 <br />0 <br />Minimum equivalent <br />Nonbear ing walls <br />thickness <br />Exterior: <br />0 <br />0 <br />0 <br />Interior: <br />0 <br />0 <br />0 <br />Floor Construction <br />Including supporting beams and Joists: <br />0 <br />0 <br />0 <br />Roof Construction <br />Including supporting beams and Joists: <br />0 <br />0 <br />0 <br />6. Opening Percentage on Exterior Walls <br />Permitted <br />Propose <br />As per FBC Table 705.8: <br />Maximum Area of Exterior Wall Openings <br />No Limit <br />--- <br />7. Fire Resistant Partitions <br />Reauired <br />Proposed <br />Design <br />As per FBC Chapter 7 and NFPA 101: <br />Flrewalls: <br />NA <br />--- <br />--- <br />Vertical Shafts: <br />NA <br />--- <br />--- <br />Occupancy Separations: <br />NA <br />--- <br />--- <br />Tenant Separations: <br />NA <br />--- <br />--- <br />Exit Access Corridors: <br />I hr <br />1 hr <br />--- <br />Refuse Chute Access Room: <br />NA <br />--- <br />Refuse Chute and Vault: <br />NA <br />--- <br />8. Building Occupancy/ Exit Calculations <br />Building Occupancy per FBC Table 1004.1.1 <br />and NFPA 101 table 7.3.1.2 (in SF/Occupant): <br />A.S.SFMRI Y ARFAS <br />Gymnasium/ Weights: 5758 SF./50 SF.per person = 76 <br />persons <br />Lockers 844 SF./50 SF.per person = 17 persons <br />Aerobics Room 1094 SF./15 SF.per person = 73 persons <br />Cycle Room 213 SF./50 SF.per person = 5 <br />persons <br />Break Room 240 SF./15 SF.per person = 16 <br />persons <br />KTtchen/Educatlon 782 SF./15 SF.per person = 53 <br />persons <br />Sub Total <br />240 persons <br />RIISINFSS/ OTHFR <br />Kitchen: 215 SF./20 SF.per person <br />= II persons <br />Message/Exam 2330 SF./100 SF.per person = 24 <br />persons <br />Miscellaneous Offices 863 SF./100 SF.per person <br />= 9 persons <br />Lobby/Lounge/Clrculatlon 1717 SF./100 SF.per <br />person = 18 persons <br />Sub Total 62 persons <br />Total Occupant Load 302 persons <br />Exit Requirements <br />9. 302 persons x 0.2' per person = 60.4' of exist width required. <br />352' of width available OK. <br />Reauired <br />Proposed <br />Max. Travel Distance: <br />200, <br />109, <br />Max. Common Travel Distance: <br />20'/75' <br />53' (less than 50 occupants, OK) <br />Max. Dead End Corridor: <br />20' <br />0 <br />Min. Corridor Width: <br />44' <br />58' <br />Min. Clear Opening of Exit Doors: <br />32' <br />32, <br />Min. Stair Width: <br />44' <br />44' Exterior Stair <br />10. Required Plumbing Fixtures, As per FPC Table 403.1 <br />Based on 120 males/ 120 females A-3 Occupancy <br />31 males/ 31 females B-Occuponcy <br />Required <br />Proposed <br />Water Closets <br />6 <br />9 <br />Lavatories <br />4 <br />7 <br />Urinals <br />--- <br />I <br />Showers <br />--- <br />6 <br />RE <br />Drinking Fountains <br />2 <br />2 HILo <br />Service Sink <br />I <br />I <br />ll. Interior Finish Requirements <br />As per FBC Table 803.5 <br />and NFPA 101 Table A 10.2.2 <br />Exits: <br />All interior finishes <br />Exit Access Corridors: <br />Class I or Class <br />A <br />Rooms & Enclosed Spaces: <br />H <br />vi <br />N <br />U <br />•� N <br />o <br />N <br />00 <br />d- <br />rn <br />U o M <br />O 4 <br />cd cn N <br />0 <br />bNU <br />o z <br />0 <br />c4 <br />P x <br />o <br />N x <br />N <br />C�3 <br />�-O-I <br />Cd <br />7� <br />O <br />tb <br />MM� <br />Cd N <br />4V <br />Project No. 14037.00 <br />A161 <br />61312015 8:47:46 AM ...\cd\AI.ILife Safety Plan.dgn <br />© 2015 BH/PK Architects, Inc. I <br />