1000 GENERAL NOTES: <br />1. STRUCTURAL. DRAWINGS SHALL BE USED IN CONJUNCTION WITH PROJECT SPECIFICATIONS <br />AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. <br />CONSULT THESE DRAWINGS FOR OPENINGS, DEPRESSIONS, EQUIPMENT WEIGHTS AND <br />LOCATIONS, MBEDDED ITEMS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. <br />2. DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. ANY DISCREPANCIES <br />SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD BEFORE PROCEEDING <br />WITH THE AFFECTED PART OF THE WORK. <br />3. NO STRUCTURAL MEMBER OR COMPONENT SHALL BE CUT, NOTCHED, OR OTHERWISE ALTERED <br />UNLESS APPROVED IN WRITING BY THE ENGINEER OF RECORD. THE CONTRACTOR SHAL_ <br />BE RESPONSIBLE FOR ANY AND ALL COSTS INCURRED BY THE ENGINEER OF RECORD FOR <br />REVIEW OF ANY SUCH DEVIATIONS. <br />4. DO NOT SCALE DRAWINGS. <br />5. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING <br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION <br />PROCEDURES AND SEQUENCE TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS <br />DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, <br />TEMPORARY BRACING, GUYS OR TIE -DOWNS. <br />6. DETAILS LABELED "TYPICAL DETAILS" ON THE DRAWINGS SHALL APPLY TO ALL <br />SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE <br />SPECIFICALLY DETAILED. THE APPLICABILITY OF THE DETAIL TO ITS LOCATION ON <br />THE DRAWIN 3S CAN BE DETERMINED BY THE TITLE OF DETAIL. SUCH DETAILS SHALL <br />APPLY WHETHER OR NOT THEY ARE REFERENCED AT EACH LOCATION. QUESTIONS <br />REGARDING APPLICABILITY OF TYPICAL DETAILS SHALL BE DETERMINED BY THE <br />ENGINEER OF RECORD. <br />7. THE GENERAL CONTRACTOR SHALL COMPARE THE ARCHITECTURAL, MECHANICAL, <br />ELECTRICAL.. PLUMBING, CIVIL AND STRUCTURAL DRAWINGS AND REPORT ANY <br />DISCREPANCIES BETWEEN EACH SET OF DRAWINGS AND WITHIN EACH SET OF DRAWINGS TO <br />THE ARCHITECT AND ENGINEER OF RECORD PRIOR TO THE FABRICATION AND <br />INSTALLATION OF ANY STRUCTURAL MEMBERS. <br />8. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED <br />STRUCTURE, AND DO NOT INDICATE THE METHOD OR MEANS OF CONSTRUCTION. THE <br />CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY <br />RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES, <br />SEQUENCE AND SAFETY. THE ENGINEER DOES NOT HAVE CONTROL OR CHARGE OF, AND <br />SHALL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES, <br />SEQUENCES. OR PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION <br />WITH THE WORK, FOR THE ACTS OR OMISSION OF THE CONTRACTOR, SUBCONTRACTOR OR <br />ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF ANY Of: <br />THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. <br />9. THE STRUCTURAL ENGINEER'S OBLIGATIONS TO REVIEW SHOP DRAWINGS AND OTHER <br />SUBMITTALS AND TO RETURN THEM IN A TIMELY MANNER ARE CONDITIONED UPON THE <br />PRIOR REVIE N AND APPROVAL OF THE SHOP DRAWINGS OR SUBMITTALS BY THE <br />CONTRACTOR AS REQUIRED IN THE CONSTRUCTION CONTRACT AND THE CONTRACTOR'S <br />SUBMITTAL OF THE SHOP DRAWINGS AND OTHER SUBMITTALS IN ACCORDANCE WITH A <br />WRITTEN SCHEDULE DISTRIBUTED IN ADVANCE TO THE ENGINEER IDENTIFYING THE DATES <br />FOR THE SUBMITTAL OF THE VARIOUS SHOP DRAWINGS AND SUBMITTALS. <br />10. PERIODIC SITE OBSERVATION BY FIELD REPRESENTATIVES OF TLC ENGINEERING FOR <br />ARCHITECTURE IS SOLELY FOR THE PURPOSE OF DETERMINING IF THE WORK OF THE <br />CONTRACTOR IS PROCEEDING IN GENERAL ACCORDANCE WITH THE STRUCTURAL CONTRACT <br />DOCUMENTS THIS LIMITED SITE OBSERVATION SHALL NOT BE CONSTRUED AS <br />EXHAUSTIVE OR CONTINUOUS TO CHECK THE QUALITY OR QUANTITY OF THE WORK. <br />11. ALL STRUCTURES REQUIRE PERIODIC MAINTENANCE TO EXCEED LIFESPAN AND TO ENSURE <br />STRUCTURAL. INTEGRITY FROM EXPOSURE TO THE ENVIRONMENT. A PLANNED PROGRAM OF <br />MAINTENANCE SHALL BE ESTABLISHED BY THE OWNER. THIS PROGRAM SHALL INCLUDE <br />ITEMS SUCH AS, BUT NOT LIMITED TO, PAINTING OF STRUCTURAL STEEL, PROTECTIVE <br />COATINGS FOR CONCRETE, SEALANTS, CAULKED JOINTS, EXPANSION JOINTS, CONTROL <br />JOINTS, SPALLS AND CRACKS IN CONCRETE, AND PRESSURE WASHING OF EXPOSED <br />STRUCTURAL. ELEMENTS EXPOSED TO SALT ENVIRONMENT OR OTHER HARSH CHEMICALS. <br />12. STRUCTURAL. ENGINEER OF RECORD IS NOT RESPONSIBLE FOR THE DESIGN OF STEEL <br />STAIRS, HANDRAILS, CURTAIN WALL/WINDOW WALL SYSTEMS, COLD -FORMED FRAMING, OR <br />OTHER SYST __MS NOT SHOWN IN THE STRUCTURAL DOCUMENTS. SUCH SYSTEMS SHAL_ BE <br />DESIGNED, FJRNISHED, AND INSTALLED AS REQUIRED BY OTHER PORTIONS OF THE <br />CONTRACT DOCUMENTS. <br />13. IN THE PROFESSIONAL OPINION OF TLC ENGINEERING FOR ARCHITECTURE, INC. THE <br />STRUCTURAL. CONTRACT DOCUMENTS FOR THIS PROJECT HAVE BEEN PREPARED IN <br />ACCORDANCE WITH THE DESIGN CRITERIA AS SET FORTH IN THE FLORIDA BUILDING <br />CODE. <br />14. NO PROVISIONS HAVE BEEN MADE FOR VERTICAL OR HORIZONTAL EXPANSION. <br />15. FINISH FLOOR ELEVATION (FIRST FLOOR) OF 0"-0" IS USED AS A REFERENCE ELEVATION. <br />SEE CIVIL DRAWINGS FOR ACTUAL ELEVATION. <br />1060 DESIGN LOADS: <br />1. THE STRUCTURAL SYSTEM FOR THIS BUILDING HAS BEEN DESIGNED IN ACCORDANCE ITH <br />THE FLORIDA BUILDING CODE, 2010 EDITION. <br />2. THE FOLLOWING SUPERIMPOSED LOADINGS HAVE BEEN UTILIZED: <br />2.1 DEAD LOADS <br />ROOF STRUCTURE 15PSF <br />2.2 LIVE LOADS <br />ROOF 20 PSF <br />FLOOR LOBBY/CORRIDOR 100 PSF <br />2.3 WIND: PER FBC 2010 BUILDING CODE, SECTION 16 <br />SEE THIS SHEET FOR COMPONENTS AND CLADDING PRESSURES <br />V=137 MPH (3 SEC. GUST) REGION <br />RISK CATEGORY=II <br />EXPGSURE =C <br />IMPACT RESISTANT GLASS OR FBC APPROVED ALTERNATIVE IS REQUIRED. <br />2 <br />v <br />ri <br />N <br />2210 DEMOLITION NOTES: <br />1. THE CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY SCAFFOLDING, PLATFORMS, <br />BARRICADES, RAILINGS, SCREENING, ETC. NECESSARY TO PROTECT EXISTING <br />FACILITIES, STRUCTURES AND THE PUBLIC DURING DEMOLITION AND ERECTION OF THE <br />NEW CONSTRUCTION, AS WELL AS FOR JOB SAFETY. JOB SAFETY, CONSTRUCTION AND <br />DEMOLITION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE <br />CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONS TO MINIMIZE VIBRATION, NOISE, <br />DUST AND DEBRIS IN ALL AREAS ADJACENT TO AREAS OF DEMOLITION. <br />2. THE CONTRACTOR IS REQUIRED TO COORDINATE WITH THE OWNER FOR THE TEMPORARY <br />SUSPENSION OF USE OF ANY FACILITY OR PORTION THEREOF, AND THE ASSOCIATED <br />BARRICADING REQUIREMENTS WITHIN A MINIMUM OF 7 DAYS PRIOR TO COMMENCING WORK. <br />3. THE CONTRACTOR IS REQUIRED TO PERFORM HIS WORK IN A MANNER, WHICH WILL NOT <br />CONFLICT WITH ANY OPERATION, WHICH IS TO REMAIN FUNCTIONAL DURING THE COURSE <br />OF THE PROJECT, UNTIL SUCH OPERATION IS SCHEDULED TO BE SHUT DOWN. <br />4. THE CONTRACTOR IS REQUIRED TO COORDINATE WITH OWNER FOR THE TEMPORARY <br />SUSPENSION OF USE OF ANY UTILITY SYSTEM, A MINIMUM OF 3 DAYS PRIOR TO <br />COMMENCING WORK. <br />5. AT ALL LOCATIONS WHERE NEW CONSTRUCTION WILL INTERFACE WITH EXISTING <br />ELEMENTS, CUT THROUGH EXISTING STRUCTURE IN STRAIGHT AND TRUE LINES TO INSURE <br />A NEAT INTERFACE. <br />6. AT ALL LOCATIONS WHERE THE DEMOLITION OF A CONCRETE MEMBER LEAVES THE ENDS OF <br />REINFORCING STEEL EXPOSED, PROVIDE THE FOLLOWING: <br />A. CHIP CONCRETE FROM AROUND THE STEEL TO A DEPTH OF 1". <br />B. CUT OFF REINFORCING STEEL NOT LESS THAN 3/4" BELOW THE CONCRETE SURFACE. <br />C. FILL THE CAVITY FLUSH WITH A HIGH MODULUS GEL EPDXY. SEE SPECIFICATIONS <br />FOR ACCEPTED MANUFACTURERS. <br />7. BEFORE DEMOLISHING ANY STRUCTURAL ELEMENT, INSTALL ALL REQUIRED TEMPORARY <br />AND/OR PERMANENT BRACING AND SUPPORTS. <br />8. PROVIDE TEMPORARY CLOSURE OF ALL ROOF FASCIA, WALL AND OTHER OPENINGS TO <br />PROTECT BUILDING FROM EXPOSURE TO UNDESIRABLE ELEMENTS UNTIL NEW CONSTRUCTION <br />IS WEATHERPROOFED, AT WHICH TIME SUCH TEMPORARY CONSTRUCTION SHALL BE <br />REMOVED. ALL TEMPORARY EXTERIOR WALLS THAT ARE SUBJECT TO WIND LOADS ARE TO <br />BE DESIGNED BY A DELEGATED ENGINEER. <br />9. UPON COMPLETION OF NEW CONSTRUCTION N E HA M UNDER EACH PHASE, ALL DEMOLISHED AREAS <br />SHALL BE RESTORED TO ACCEPTABLE USAGE ACCORDING TO THE CONTRACT DOCUMENTS AS <br />DETERMINED BY THE A/E. <br />10. REMOVE COMPLETELY FROM THE SITE AND LEGALLY DISPOSE ALL DEBRIS GENERATED BY <br />THE DEMOLITION WORK AS THE WORK PROGRESSES. STOCKPILING OF DEBRIS AND <br />BURNING OF DEBRIS ON THE PREMISES IS STRICTLY PROHIBITED. <br />2300 FOUNDATIONS - W/O SOIL REPORTS: <br />1. IN THE ABSENCE OF ANY GEOTECHNICAL RECOMMENDATIONS THE FOUNDATIONS ARE <br />DESIGNED FOR AN ANTICIPATED ALLOWABLE SOIL BEARING PRESSURE OF 2,000 psf ON <br />COMPACTED FILL. FOR PRELIMINARY PRICING PURPOSES ONLY, BEFORE CONSTRUCTION <br />COMMENCES, SOIL BEARING CAPACITY SHALL BE VERIFIED BY A SUBSURFACE <br />INVESTIGATION, AS WELL AS FIELD AND LABORATORY TESTS PERFORMED BY A CERTIFIED <br />TESTING LABORATORY, WHOSE REPORT SHALL INCLUDE ANALYSIS AND RECOMMENDATIONS <br />FOR SITE PREPARATION IN ORDER TO BEAR THE FOUNDATION LOADS. ABOVE REPORT <br />SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW BEFORE FOUNDATION <br />CONSTRUCTION BEGINS. <br />2. REGARDLESS OF WHETHER OR NOT A GEOTECHNICAL INVESTIGATION IS PERFORMED, NO <br />WARRANTIES, EXPRESSED OR IMPLIED, ARE MADE BY TLC FOR THE PERFORMANCE OF THE <br />FOUNDATION. <br />3302 CONCRETE: <br />1. SHALL BE PER AN APPROVED MIX DESIGN PROPORTIONED TO ACHIEVE A STRENGTH AT 28 <br />DAYS AS LISTED BELOW WITH A PLASTIC AND WORKABLE MIX: <br />LOCATION STRENGTH SLUMP MAX AGGREGATE WCM RATIO (MAX) <br />FOUNDATIONS 3000 PSI 4-6" 3/4" 0.48 <br />SLABS ON GRADE 3000 PSI 4-6" 3/4" 0.48 <br />ELEVATED SLABS 5000 PSI 4-6" 3/4" 0.42 <br />BEAMS/COLUMNS 5000 PSI 4-6" 3/4" 0.42 <br />TILT WALL PANELS 4000 PSI 4-6" 3/8" 0.48 <br />CONCRETE TOPPING 3000 PSI 4-6" 3/8" 0.48 <br />OTHER STRUCTURAL 400C PSI 4-6" 3/4" 0.45 <br />CONCRETE <br />2. CONCRETE SHALL BE PLACED AND CURED ACCORDING TO ACI STANDARDS AND <br />SPECIFICATIONS. <br />3. WHERE SPECIFIED CONCRETE STRENGTH OF COLUMN IS GREATER THAN THE SPECIFIED <br />SLAB CONCRETE STRENGTH, HIGHER STRENGTH CONCRETE SHALL BE PUDDLED AT THE <br />COLUMN. THE STRENGTH OF PUDDLED CONCRETE SHALL BE AT LEAST 0.72 TIMES THE <br />STRENGTH OF COLUMN CONCRETE PER ACI 318, 10.15. <br />4. SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CYLINDER OR LAB TESTS FOR REVIEW <br />PRIOR TO USE. MIX SHALL BE UNIQUELY IDENTIFIED BY MIX NUMBER OR OTHER <br />POSITIVE IDENTIFICATION. MIX SHALL MEET THE REQUIREMENTS OF ASTM C33 FOR <br />COARSE AGGREGATE. <br />5. CONCRETE SHALL COMPLY WITH THE REQUIREMENTS OF ASTM STANDARD C94 FOR <br />MEASURING, MIXING, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME STAMPED <br />WHEN CONCRETE IS BATCHED. <br />6. THE MAXIMUM TIME ALLOWED FROM THE TIME THE MIXING WATER IS ADDED UNTIL IT IS <br />DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED ONE AND ONE HALF (1-1/2) <br />HOURS. IF FOR ANY REASON THERE IS A LONGER DELAY THAN THAT STATED ABOVE, THE <br />CONCRETE SHALL BE DISCARDED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING <br />LAB TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY <br />NONCOMPLIANCE WITH THE ABOVE. <br />7. SLABS SHALL BE CURED USING A DISSIPATING CURING COMPOUND MEETING ASTM <br />STANDARD C309 TYPE 1-CLASS D AND SHALL HAVE A FUGITIVE DYE. THE COMPOUND <br />SHALL BE PLACED AS SOON AS THE FINISHING IS COMPLETED OR AS SOON AS THE WATER <br />HAS LEFT THE UNFINISHED CONCRETE. SCUFFED OR BROKEN AREAS IN THE CURING <br />MEMBRANE SHALL BE RECOATED DAILY. <br />8. CALCIUM CHLORIDES SHALL NOT BE UTILIZED; OTHER ADMIXTURES MAY BE USED ONLY <br />WITH THE APPROVAL OF THE ENGINEER. <br />9. CONCRETE MIX DESIGNS SHALL INCLUDE A WRITTEN DESCRIPTION INDICATING WHERE <br />EACH PARTICULAR MIX IS TO BE PLACED WITHIN THE STRUCTURE. <br />10. CONDUITS, PIPES AND SLEEVES SHALL BE PLACED AND SPACED IN ACCORDANCE WITH ACI <br />318, 6.3. <br />11. PEA ROCK PUMP MIX USE IS LIMITED TO VERTICAL ELEMENT POURS AND BEAM POURS <br />LESS THAN 60 LINEAR FEET PER POUR. <br />12. CONCRETE DESIGN MIX SUBMITTALS SHALL INCLUDE TESTED, STATISTICAL BACK-UP DATA <br />AS PER CHAPTER 5 OF ACI 318. <br />13. WATER/CEMENT RATIO FOR CONCRETE AT EXTERIOR BALCONIES SHALL NOT EXCEED 0.40 <br />BY WEIGHT. <br />14. ALL COLUMNS AND BEAMS INTEGRATED IN CMU WALLS ARE 8" AND 12" NOMINAL AND 7- <br />5/8" AND 11-5/8" ACTUAL DIMENSIONS. <br />15. CONCRETE SLABS ON GRADE SHALL BE REINFORCED WITH SYNTHETIC FIBERS AT A <br />MINIMUM RATE OF 1.5 LBS/CY, OR AS RECOMMENDED BY THE FIBER MANUFACTURER FOR <br />CONTROL OR TEMPERATURE AND SHRINKAGE/CRACKING, WHICHEVER IS GREATER. <br />16. WHEN TOTAL WIDTH OF PIPES OR DUCTS CAST INTO A SLAB EXCEED 12" IN A 24" WIDTH <br />THEN THE CONTRACTOR SHALL ADD A LAYER OF #4 @ 12" ABOVE AND PERPENDICULAR TO <br />THE DUCT/PIPE RUNS EXTENDING 12" BEYOND THE LAST DUCT/PIPE ON EACH SIDE. <br />17. WHEN WATER -BASED ADHESIVE ARE BEING USED ON CONCRETE SURFACES THE CONTRACTOR <br />SHALL VERIFY THAT THE WATER CONTENT OF THE CONCRETE IS WITHIN THE ALLOWABLE <br />RANGE BEFORE INSTALLATION <br />3310 REINFORCING STEEL: <br />1. SHALL BE ASTM A615 GRADE 60 DEFORMED BARS, FREE FROM OIL, SCALE AND RUST AND <br />PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF <br />ACI STANDARDS AND SPECIFICATIONS. <br />2. PROVIDE CONCRETE COVER OVER REINFORCEMENT AS FOLLOWS, UNLESS OTHERWISE NOTED: <br />BEAMS 1-1/2" <br />SLABS AND JOISTS 3/4" <br />COLUMNS AND WALLS 1-1/2" <br />FOOTINGS AND PILE CAPS 3" <br />CONCRETE EXPOSED TO EARTH OR WEATHER 2"46 BARS OR LARGER <br />1-1/2"45 BARS OR SMALLER <br />3. SECURE APPROVAL OF SHOP DRAWINGS PRIOR TO COMMENCING FABRICATION. <br />4. PROVIDE STANDARD HOOKS AT DISCONTINUOUS ENDS OF ALL TOP BARS. <br />5. WHERE REINFORCING IS SHOWN CONTINUOUS, SPLICE BOTTOM BARS OVER SUPPORTS AND <br />TOP BARS AT CENTER OF SPAN. ALL OTHER LAP SPLICES SHALL BE IN ACCORDANCE <br />WITH SPLICE TABLES AND DETAILS SHOWN ON DRAWINGS. <br />6. PROVIDE DOWELS INTO FOOTINGS, PILE CAPS, SUPPORT BEAMS, ETC. TO MATCH <br />VERTICAL BARS WITH CLASS B TENSION LAP SPLICES, U.N.O. <br />4810 MASONRY WALLS: <br />1. ALL MASONRY CONSTRUCTION SHALL CONFORM TO ACI 530/ASCE 5/TMS 402 "BUILDING <br />CODE REQUIREMENTS FOR MASONRY STRUCTURES" AND ACI 530.1/ASCE 6/TMS 602 <br />"SPECIFICATION FOR MASONRY STRUCTURES", LATEST EDITION. <br />2. MASONRY UNITS SHALL MEET ASTM C-90 FOR HOLLOW LOAD BEARING TYPE MASONRY WITH <br />UNIT STRENGTH OF 1900 PSI ON THE NET AREA (f'm = 2000 PSI). MORTAR SHALL BE <br />TYPE "M" OR "S" AND MEET ASTM C-270. <br />3. GROUT SHALL BE 2000 PSI MINIMUM COMPRESSIVE STRENGTH AND MEET ASTM C-476 AND <br />HAVE A SLUMP BETWEEN 8" AND 11" WITH WATER CM RATIO OF 0.55 MAXIMUM AND WITH <br />3/8" MAXIMUM AGGREGATE. <br />4. PROVIDE HOOKED DOWELS IN FOUNDATIONS FOR VERTICAL REINFORCING ABOVE. LAP <br />SPLICES TO BE 48 BAR DIAMETERS (U.N.O.). <br />5. BLOCK CELLS SHALL BE GROUT FILLED WITH VERTICAL REINFORCING BARS AT CORNERS, <br />INTERSECTIONS, EACH SIDE OF OPENINGS AND AS SHOWN ON THE DRAWINGS. <br />6. DOWELS SHALL BE USED TO PROVIDE CONTINUITY INTO THE STRUCTURE ABOVE AND/OR <br />BELOW, UNLESS NOTED OTHERWISE. <br />7. USE METAL LATH, MORTAR OR SPECIAL UNITS TO CONFINE CONCRETE AND GROUT TO AREA <br />AS REQUIRED. <br />8. MASONRY SHALL BE LAID IN RUNNING BOND PATTERN UNLESS NOTED OTHERWISE. AT <br />FILLED CELLS LAY UNITS WITH FULL BED JOINTS AROUND CELLS. <br />9. PROVIDE 9 GAGE GALVANIZED HORIZONTAL JOINT REINFORCING (DUR-O-WALL OR <br />ENGINEER APPROVED SUBSTITUTION) AT ALTERNATE BLOCK COURSES. LADDER TYPE IS <br />RECOMMENDED WITH REINFORCED FILLED CELLS. PROVIDE PREFABRICATED "TEE" OR <br />CORNER SECTIONS AT WALL INTERSECTIONS. <br />10. CONTROL JOINTS SHALL BE CONSTRUCTED IN CONCRETE MASONRY CONSTRUCTION AT A <br />MAXIMUM HORIZONTAL SPACING BETWEEN JOINTS OF 25-0" AND NOT MORE THAN 12'6" <br />FROM CORNERS. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS. CONSTRUCT <br />INTERIOR CONTROL JOINTS AT A MAXIMUM HORIZONTAL SPACING OF 32'-0" OR 16'-0" <br />FROM CORNERS. NO JOINTS SHALL BE LOCATED WITHIN 2'-0" OF STEEL BEAM BEARINGS. <br />HORIZONTAL WALL REINFORCING SHALL BE STOPPED EACH SIDE OF CONTROL JOINTS. <br />SEE ARCHITECTURAL DRAWINGS FOR SEALANT REQUIREMENTS AT CONTROL JOINTS. <br />11. SUBMIT PROPOSED GROUT MIX DESIGNS FOR REVIEW PRIOR TO USE. MIX NUMBER OR <br />OTHER POSITIVE IDENTIFICATION SHALL UNIQUELY IDENTIFY MIX. <br />12. USE OF SUPERPLASTICIZER IS PROHIBITED. <br />13. CELLS TO BE GROUT FILLED SHALL HAVE VERTICAL ALIGNMENT SUFFICIENT TO MAINTAIN <br />A CLEAR, UNOBSTRUCTED, CONTINUOUS VERTICAL GROUT SPACE. <br />14. CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF CELLS TO BE GROUT FILLED <br />IN EACH POUR IN EXCESS OF 5 FEET IN HEIGHT. AFTER INSPECTION AND BEFORE <br />GROUTING, THE REBAR SHALL BE TIED AT THE CLEANOUTS AND THE CLEANOUTS SHALL BE <br />SEALED. <br />15. ANY OVERHANGING MORTAR OR OTHER OBSTRUCTION OR DEBRIS SHALL BE REMOVED FROM <br />THE INSIDES OF SUCH CELL WALLS, <br />16. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT TOP AND BOTTOM AND AT <br />INTERVALS NOT EXCEEDING 192 BAR DIAMETERS. <br />17. CELLS CONTAINING REINFORCEMENT SHALL BE FILLED SOLIDLY WITH GROUT. SAMPLE <br />AND TEST GROUT PER ASTM C1019. <br />18. GROUT SHALL BE POURED IN LIFTS OF 4 FEET MAXIMUM HEIGHT. GROUT SHALL BE <br />CONSOLIDATED AT TIME OF PLACING BY VIBRATING AND RECONSOLIDATED LATER BY <br />VIBRATING BEFORE PLASTICITY IS LOST. <br />19. WHEN TOTAL GROUT POUR EXCEEDS 5 FEET IN HEIGHT, (HIGH LIFT GROUTING), THE <br />GROUT SHALL BE PLACED IN 4-FOOT LIFTS WITH A MINIMUM OF A 30 MINUTE DELAY <br />BETWEEN LIFTS. MINIMUM CELL DIMENSION SHALL BE IN ACCORDANCE WITH TABLE 5 OF <br />ACI 530.1 (3" X 3" FOR COARSE GROUT, 12 FT. MAXIMUM POUR HEIGHT). <br />20. WHEN THE GROUTING IS STOPPED FOR ONE HOUR OR LONGER, HORIZONTAL CONSTRUCTION <br />JOINTS SHALL BE MADE BY STOPPING THE POUR OF GROUT NOT LESS THAN 1-1/2 INCH <br />BELOW THE TOP OF THE UPPERMOST UNIT GROUTED. <br />21. WHERE CONCRETE BEAMS ARE INSTALLED IN CONCRETE MASONRY WALL, SUPPORT CONCRETE <br />WITH 6" WIDE CONTINUOUS STRIPS OF 1/8 SQUARE MESH SOFFIT SCREENING OR PUR-O- <br />STOP OF EQUAL CENTERED OVER BLOCK WORK. USE OF ROOFING FELT STRIPS WILL NOT <br />BE PERMITTED. <br />22. MASONRY WALLS MARKED AS "LOAD BEARING" ARE DESIGNED TO CARRY FLOOR GRAVITY <br />LOADS AND MUST BE CONSTRUCTED TO SUPPORT THE CONCRETE FLOOR SLAB CONCURRENTLY <br />WITH CONCRETE COLUMN CONSTRUCTION. <br />23. MASONRY WALLS INDICATED AS "INFILL" ARE DESIGNED TO RESIST LATERAL LOADS AND <br />MUST BE CONSTRUCTED AFTER THE CONCRETE SLAB IS CAST AND POST TENSIONING <br />OPERATION IS COMPLETED. INFILL WALLS SHALL BE CONSTRUCTED STARTING AT THE <br />FOUNDATION LEVEL AND WORKING UPWARD ONE LEVEL AT A TIME. DO NOT START NEXT <br />HIGHER LEVEL OF WALL PRIOR TO COMPLETION OF WALL BELOW. ALLOW A MINIMUM OF 3 <br />DAYS CURING FOR GROUT OF WALL BELOW PRIOR TO STARTING WALL ABOVE. <br />24. SINGLE STORY MASONRY WALLS INDICATED AS "PARTITION WALLS" SHALL BE CAST ON <br />THICKENED SLAB FOUNDATIONS AND ARE NOT DESIGNED TO CARRY ANY LOADS FROM THE <br />MAIN BUILDING STRUCTURES. ISOLATE TOP OF PARTITION WALLS FROM UNDERSIDE OF <br />CONCRETE SLAB WITH A MINIMUM 1/2" THICK COMPRESSIBLE MATERIAL. <br />25. PROVIDE DOVETAIL ANCHORS AT 16" C/C, UNLESS NOTED OTHERWISE, WHERE MASONRY <br />WALLS ABUT CONCRETE SURFACES. <br />26. SUBMIT WRITTEN CONSTRUCTION SEQUENCES AND PROCEDURES PRIOR TO THE START OF <br />MASONRY CONSTRUCTION. <br />6103 WOOD: <br />1. WOOD CONSTRUCTION SHALL CONFORM TO AITC, NATIONAL DESIGN SPECIFICATION. <br />2. STRUCTURAL WOOD COMPONENTS (BEAMS, JOISTS, RAFTERS, ETC.) SHALL HAVE THE <br />FOLLOWING MINIMUM ALLOWABLE FIBER STRESSES OF NO. 2 SOUTHERN PINE CONFORMING <br />TO THE LATEST EDITION OF NDS, AS FOLLOWS: <br />SHEAR Fv = 90 PSI. <br />BENDING 2X6 FB = 1,250 PSI. <br />BENDING 2X8 FB = 1,200 PSI. <br />BENDING 2X10 FB = 1,050 PSI. <br />BENDING 2X12 FB = 975 PSI <br />3. STANDARD U.S.S. WASHERS SHALL BE USED BETWEEN WOOD AND BOLT HEADS AND NUTS. <br />BOLTS AND SCREWS SHALL BE ASTM A-307, ALL SHALL BE GALVANIZED. <br />4. WHERE BEAMS ARE FORMED WITH TWO OR MORE MEMBERS, THEY SHALL BE ADEQUATELY <br />FASTENED TOGETHER THROUGHOUT THEIR LENGTH. <br />5. JOISTS SHALL BE ADEQUATELY SUPPORTED AT THEIR ENDS BY SOLID BLOCKING OR OTHER <br />MEANS TO PREVENT ROTATION. <br />6. STUD WALLS SHALL BE: <br />A. SHEAR WALL: 2X4 #2 SOUTHERN YELLOW PINE @ 16" WITH 1/2" NOM. CDX EXP <br />EXTERIOR GRADE PLYWOOD. NAIL PLYWOOD TO ALL SUPPORTS WITH 8d NAILS AT 4; <br />O.C. AT ALL PLYWOOD EDGES AND @ 12" O.C. AT INTERMEDIATE FRAMING MEMBERS. <br />B. BEARING WALLS: 2X4, U.N.O. ON DWGS., #2 SOUTHERN YELLOW PINE @ 16" O.C. <br />PROVIDE ADEQUATE ANCHORAGE FOR UPLIFT FORCE AS INDICATED IN TRUSS MFR'S. <br />CALCULATIONS. <br />C. OTHER WALLS: 2X4 #2 SOUTHERN YELLOW PINE @ 16" O.G. <br />7. DOUBLE STUDS SHALL BE PROVIDED AT EACH END OF BEAMS AND ON EACH SIDE OF <br />OPENINGS. 4'-0" WIDTH. PROVIDE TRIPLE STUDS EACH SIDE OPENINGS TO T-0" IN <br />WIDTH, U.N.O. <br />8. WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED OR PRESSURE <br />TREATED IN ACCORDANCE WITH AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS. <br />USE AWPA TREATMENT C1 USING WATER -BORNE PRESERVATIVE. <br />9. MEMBER SIZES SHOWN ARE NOMINAL UNLESS NOTED OTHERWISE. <br />10. PLYWOOD ROOF SHEATHING SHALL BE NAILED AND GLUED TO WOOD FRAMING IN <br />ACCORDANCE WITH THE FLORIDA BUILDING CODE AND APA SPECIFICATION AFG-01, <br />ADHESIVES FOR FIELD GLUING PLYWOOD TO WOOD FRAMING. <br />STRUCTURAL SYMBOLS AND LEGEND, <br />DETAIL NUMBER <br />I <br />SHEET NUMBER <br />\.. X <br />177 <br />SLOPE <br />RUN <br />12 <br />14- RISE <br />SECTION / DETAIL MARK <br />ELEVATION MARK <br />RECESS OR STEP IN SLAB <br />SLOPED SURFACE <br />PITCHED ROOF <br />PLAN NOTE <br />SPAN DIRECTION <br />STEP HEIGHT <br />STEP FOUNDATION o <br />CniCV - <br />- _ - - STEPPED FOUNDATION <br />F6.0 <br />� CC-1 I <br />L - J <br />Y <br />COLUMN AND FOUNDATION <br />TYPE MARKS <br />SPOT ELEVATION, TYPICALLY <br />TOP OF ITEM TAGGED <br />(T/WALL, T/FOUNDATION, ETC) <br />WALL TYPE DESIGNATION TAG <br />INCREASED FLOOR LOAD <br />AREA IN PSF <br />WALL TYPES <br />LOAD BEARING MASONRY WALL <br />NOTE: SYMBOLS AND LEGEND SHOWN ARE <br />GENERIC AND DO NOT NECESSARILY INDICATE <br />ACTUAL OCCURRENCES IN THESE DRAWINGS. <br />STRUCTURAL SHEET INDEX <br />SHEET <br />SHEET TITLE <br />REVISION <br />REVISION <br />DATE <br />S.1 <br />STRUCTURAL NOTES <br />S.2 <br />STRUCTURAL FOUNDATION PLAN <br />S.3 <br />STRUCTURAL ROOF FRAMING PLAN <br />SA <br />STEPPED FOUNDATION ELEVATIONS <br />S.5 <br />STRUCTURAL DETAILS <br />ENEN <br />FOR ARCHITECTURE <br />500 N. Westshore Blvd. <br />Tampa, Florida 33609 <br />PH: 813.637.01 10 <br />Fax: 813.637.0013 <br />www.tic-engineers.com <br />EB #0000015 <br />C Copyright 2013 TLC Engineering for Architecture, Inc. <br />Z <br />® <br />J <br />LL <br />D <br />J <br />J <br />W <br />m <br />N <br />_ <br />W <br />N <br />� g� <br />1y A <br />J <br />VJ <br />C) <br />co <br />® <br />_J <br />J <br />VJ <br />0 <br />W <br />® <br />O <br />ti <br />I..L <br />OW <br />_J <br />3: <br />LL <br />Revisions: <br />No. Date Description <br />Digitally sig <br />Fusco P.E. <br />woa.,d.tusco .ac-eng.com, <br />David Fus ti P.E. 74504 OZLC Engine kehn for <br />Arthitecture, CN=CTavid <br />Fusco: P. E. 74504 <br />Date: 2015.06.:.01 <br />17:16:04-04'00' <br />PERMIT SET <br />Project No.: 715002 <br />Issue Date: <br />06-01-2015 <br />Drawn By: RSZ <br />Approved By: DAF <br />Scale: 3/32" = V-0" <br />Drawing Title: <br />STRUCTURAL <br />NOTES <br />Drawing No.: <br />S.1 <br />He <br />