Laserfiche WebLink
MT <br />N <br />V_ <br />N <br />O <br />\ <br />rn O <br />N <br />03 <br />FL I A PITA P <br />OR D HOS z <br />ly I <br />I RH S <br />W NES S <br />NT BU LD N M <br />C R I I G <br />r <br />i <br />ci� <br />t <br />Adventist 14ealth Systeria <br />d <br />Stiribelt14-ealth Cc)rperaticoia <br />38233 <br />Road. <br />Zi.L%.11r_-_).hyrhi11s., IF 33541 <br />PRO ECT TEAM DIRECTORY <br />SYMBOLS AND <br />MATERIALS <br />GENERAL NOTES <br />INDLX <br />A0.0 <br />Cover Sheet <br />OWNER <br />A.l COLUMN REFERENCE <br />/��/��/ EARTH <br />Industry standards (i.e. ASTM, ANSI, etc.) SHALL HAVE THE SAME FORCE AND EFFECT <br />on performance of work as if copies were directly inserted into the Contract Documents or bound and <br />therewith. Comply with standards in effect as of the date of the Contract Documents, <br />TT <br />STRUCTURAL <br />TTn A <br />published <br />Florida Hospital Zephyrhills <br />OWINDOW TYPE <br />� <br />COMPACTED SUBGRADE <br />unless otherwise note or required by authorities having jurisdiction. <br />S 1.O <br />Notes <br />7050 Gall Boulevard <br />_ _- _ _ _ _ _ _ CENTERLINE OR FLOOR LINE <br />ELEVATION BENCHMARK <br />METAL <br />I. Contractor to oversee cleaning and insure that the premises are maintained free of rubbish during construction. Final cleanup is the <br />responsibility of the Contractor. Contractor to provide Permitting Authority with Debris Affidavit at time of submittal. <br />S2.0 <br />S3.0 <br />F)undation Plan <br />Roof Framing Plan <br />Zephyrhills, Florida 33541 <br />2 <br />2. At the termination of work, submit to Owner maintenance manuals presenting full details for care and maintenance of all <br />S4.0 <br />Stepped Foundadtion Elevations <br />Phone: (813) 788-0411 <br />REVISION & NUMBER <br />® FINISH WOOD <br />surfaces and equipment of every nature. Contents shall include manufacturer's and installer's names, addresses, and phone numbers, and <br />Instructions for Installotlon, start-up, operation, maintenance parts Ilst, and data sheets. <br />S5.0 <br />1)etalls <br />C.J.D CONTROL JOINT <br />EIFS/DEFS OR GYPSUM BOARD <br />J. Contractor is responsible for compliance with all Codes, Ordinances and Regulations applicable at project location. Contractor is responsible <br />for filing and securing all necessary permits, approvals, etc. for all trades. <br />ARCHITECTURAL <br />ARCHITECT <br />E.J.► EXPANSION JOINT <br />INSULATION BOARD -SECTION <br />4. When 'or equal', 'alternate', or other qualifying terms are used, those items shall be approved by Owner and/or Architect/ Engineer. <br />A1.0 <br />ALL <br />Site Plan <br />r <br />Life Safety Plan <br />Burt Hill / Pollock Krieg Architects Inc <br />� . � . CONCRETE OR GRAVEL <br />5. Existing materials or items scheduled to remain that are damaged by construction shall be repaired, patched, and refinished to the nearest <br />intersection, restoring surface to it's original condition. <br />A1.2 <br />Demolition Plan <br />� <br />NEW DOOR & FRAME <br />° � ° <br />Al .3 <br />Demolition Reflected Ceiling Plan <br />13 099 South Cleveland Avenue Suite 500 <br />NEW METAL STUD WALL <br />6. Contractor shall protect all existing walls, doors, frames, surfaces, fixtures, finishes, etc. from damage during demolition and construction. Existing <br />materials to be removed shall be coordinated with Owner to verify if Owner wishes to salvage same. <br />A2.0 <br />Floor Plan <br />Fort Myers, Florida 33907 <br />NEW MASONRY WALL <br />CONCRETE MASONRY UNIT (CMU) <br />A2.1 <br />Reflected Ceiling Plan <br />p <br />Phone: (2 3 9) 482-4761 <br />_------- WALL TO BE DEMOLISHED <br />PLYWOOD <br />® <br />7. Contractor shall verify and be responsible for all dimensions and job site conditions related to this work. Any discrepancy in dimensions or <br />special modifications required due to field conditions shall be reported to the Architect for clarification <br />A2.2 <br />A2.3 <br />Roof Plan <br />Enlarged Plan <br />Fax: (23 9) 482-0265 <br />CORRIDOR <br />KJl97 ROOM NAME & NUMBER <br />ACOUSTIC CEILING TILE <br />8. The Architect does not have control or charge of, and shall not be held responsible for construction means, methods, techniques, sequence or for <br />safety precautions and programs in connection with work, for the acts or omissions of the contractor, sub -contractors or any other persons <br />A2.4 <br />A3.0 <br />Enlarged Plan <br />Exterior elevations <br />performing any of the work, or for the failure of any of them to carry out the work in accordance with the Documents. <br />A3.1 <br />Interior Elevations <br />�oia DOOR NUMBER <br />® BATT OR SEMI -RIGID INSULATION <br />9. All pipes, ducts, conduit, etc., which penetrate the final slab or walls shall be installed so os to maintain the fire resistive and structural Integrity <br />A3.2 <br />Interior Elevations <br />TR UC ENGINEERS <br />of the building construction.S <br />A3.3 <br />Interior Cabinet Details <br />V 1� <br />SECTION OR DETAIL <br />RIGID INSULATION <br />10. Demolition of existing construction necessary to install new construction and equipment is to be performed by the contractor who is to <br />supply and install the new construction and equipment. Install lintels where required with prior written approval. <br />A4.0 <br />Sections <br />TLC Engineering for Architecture <br />Contractor to floor fill Grind high Floors to be to <br />A4.1 <br />Sections <br />uo ELEVATION <br />ROUGH WOOD FRAMING OR BLOCKING <br />H. repair slabs, gaps, cracks and voids. smooth any spots or ridges. prepared as required <br />receive floor finishes so that previous substrate defects cannot be detected. <br />A4.2 <br />Sections and Details <br />500 N. Westshore Boulvard, Suite 435 <br />A5.0 <br />Door and Window Schedule and Elevations <br />Tampa, FL 33609 <br />INTERIOR ELEVATION <br />� CONCRETE ROOF TILE <br />12. GENERAL CONDITIONS OF THE CONTRACT, AIA Document A201, latest edition, shall apply. <br />A5.1 <br />Door and Window Details <br />Phone: 81.E -63 7-'0110 <br />NORTH <br />METAL ROOFING <br />13. All gypsum board in partitions around 'wet use areas' and behind file ( i.e.: Toilet Room(s), Laundry Room(s), Shower Room(s), etc.) shall be of <br />moisture -resistant type board behind file in showers to be cementltious backer board. <br />A5.2 <br />A6.0 <br />Partition Types <br />Floor Finishes Plan <br />Fax: 811-63 7-00 13 <br />PLAN NORTH <br />14. All studs, furring and miscellaneous metal accessories in walls having moisture -resistant gypsum board are to be of golvonlzed metal. <br />A6.1 <br />Wall Finishes Plan <br />® SUPPLY DIFFUSER <br />BRICK PAVERS <br />15. All fire -rated partitions are to extend to deck above, and have ail voids packed between the deck and top of wall with fire sofeing insulation. <br />Floor track is to be set in a bed of sealant. Joints in gypsum board partitions are to be taped over the full height of the partition. <br />A6.0 <br />A6.1 <br />Finish Plan <br />Finish Plan <br />MECHANICAL/ ELECTRICAL ENGINEERS <br />® RETURN GRILLE <br />�--�� STRIP FLOURESCENT FIXTURE <br />� PARABOLIC LIGHT FIXTURE <br />16. Fire extinguisher cabinets mounting height to be 2' 6' from floor to bottom of receptacle. Top of extinguisher to be 4' 0' AFF, max. <br />PLUMBING <br />KPI Engineering, Inc. <br />CEILING FAN <br />FLOURESCENT LIGHT FIXTURE <br />17. Not all listed GENERAL NOTES may apply, nor are they all-inclusive for every work situation. <br />PLO <br />Legends, General Notes and Fixtures Schedules <br />g <br />3203 Queen Palm Drive <br />0 <br />RECESSED LIGHT FIXTURE <br />18. Each new FIRE WALL, FIRE BARRIER, FIRE PARTITION, SMOKE BARRIER, SMOKE PARTITION, or any other new wall <br />required to have protected openings shall be permanently identified with signs or stenciling above any <br />P2.0 <br />Demolition Plan <br />Tampa, Florida 33619 <br />decorative ceiling and in concealed spaces with the words,'FIRE AND SMOKE BARRIER - PROTECTED ALL OPENINGS', <br />or similar language. Sign or stenciling to include UL Design number of partition. Such signs or stenciling shall be in 4-inch <br />high letters, %-inch stroke, and not more than 15-feet on center. Per Florida Fire Protection Code 101:8.3.2.4. Penetrations <br />P3.0 <br />unitary and Vent Plan <br />through fire walls to be identified in the some manor. <br />P4.0 <br />Domestic Water <br />Ph 813.241.6488 ext 214 Fax 813.241.6498 <br />P5.0 <br />Details <br />P6.0 <br />Details <br />(�W�C U <br />P7.0 <br />6 anitary and Vent Riser Diagram <br />9 0.0- <br />P8.0 <br />Domestic Water Riser Diagram <br />,- <br />MECHAVICAL <br />VICINITY MAP <br />4�s <br />M1.0 <br />Legends, Abbreviations, and General Notes <br />M2.0 <br />Partial Demolition Plan <br />I <br />M2.1 <br />Partial Demolition Plan <br />s <br />T -- I C' <br />REVIEW QA <br />M2.2 <br />Partial Demolition Plan <br />.. . ....... . <br />CITY OF ZEPHYRH1LL <br />M3.0 <br />Partial 1 VAC Plan <br />PLAINS EXAMINER <br />M3.1 <br />Partial HVAC PLan <br />x <br />M3.2 <br />Partial HVAC Plan <br />. Y.: - <br />M3.3 <br />1VAC Piping Plan <br />-E <br />M4.0 <br />Details <br />_.1 <br />ALL o snAi�i� COMPLY WiTff All <br />�gVAIL �r CODE FLOitIl�A�3UiLLTNCs <br />M5.0 <br />ELECTRICAL <br />c►c e u es <br />- f< 0,� <br />� . <br />ANIIk <br />9 <br />Project <br />C IE, IATI �C�' C CODE <br />ORDINANCES�� <br />E1.0 <br />Legends, Abbreviations, and General Notes <br />o <br />c° � <br />- J <br />E2.0 <br />Demolition Plan <br />; <br />E3.0 <br />Lighting Plan <br />4 ' <br />E4.0 <br />Power Plan <br />' <br />E5.0 <br />Panel Schedules and Riser Diagram <br />1)`{ <br />E6.0 <br />Dire Alarm <br />61312015 8:47:43 AM ...\cd\AO-0 Cover Sheet.dgn <br />