ELECTRICAL OUTLET BOXES SMALL BE INSTALLED ON ONE
<br />SIDE ONLY IN EACH FRAMING SPACE, PROVIDED THE
<br />OPENING DOES NOT EXCEED 16 SQ. IN. ALL CLEARANCES
<br />BETWEEN THE OUTLET BOXES AND THE GYPSUM BOARD MUST
<br />BE COMPLETELY FILLED WITM JOINT COMPOUND OR OTHER
<br />APPROVED MATERIAL.
<br />4" SQUARE BOX ,_ 31
<br />1
<br />RIGID OR EMT CONDUIT CONNECT
<br />GROUNDING LUGS OF RECEPTACLES
<br />-is W!M=
<br />BACK TO BACK ELECTRICAL
<br />OUTLETS DETAIL
<br />TYPICAL ROUGH -IN
<br />REQUIREMENTS DETAIL
<br />METAL STUD
<br />^ROVIDE CONDUIT SUPPORTS
<br />4 ACCORDANCE WITH NEC.
<br />PACING REQUIREMENTS FOR
<br />YPE OF RACEWAY REQ'D.
<br />YPICAL OUTLET BOX
<br />TEEL CITY NO. 1501
<br />SOX SUPPORT
<br />I ACCORDANCE WITH
<br />3C 4304 OUTLET ON
<br />PPOSITE SIDES OF WALLS
<br />I THE SAME STUD SPACE
<br />UST BE SEPARATED BY
<br />MINIMUM OF 24" HORIZ,
<br />]DISTANCE
<br />NO OUTLETS BACK TO
<br />BACK ( OFFSET 12" )
<br />STRUCTURAL UNIT
<br />BEAM CLAMP OR HANGER
<br />CLAMP AS REQUIRED BY
<br />WEIGHT SUPPORTED
<br />ALL THREAD — SIZE AS
<br />REQUIRED
<br />RACEWAY — 1/2" THROUC-A4T 6"
<br />CONDUIT HANGER
<br />STRUCTURAL UNIT
<br />BEAM CLAMP OR MANGER
<br />CLAMP AS REQUIRED BY
<br />WEIGHT SUPPORTED
<br />RACEWAY - I/2" THROUGwT 6"
<br />NOTE:
<br />TIE WIRE SHALL NOT BE USED AS A COMPONENT
<br />OF ANY RACEWAY HANGER SYSTEM.
<br />TYPICAL RACEWAY SUPPORT METHODS DETAIL
<br />CONDUIT TO OTHER
<br />FIXTURES —�
<br />LIGHT FIXTURE
<br />1/2" d1a FLEXIBLE CONDUIT TO
<br />EACH LIGHT ( 6' LONG )
<br />LIGHT FIXTURE —4 11/16" sq. x 1 1/2" DEEP
<br />JUNCTION BOX MAX. 4 TAP
<br />CONDUIT TO PANEL50ARD OR
<br />OTHER FIXTURES
<br />RECESSED LIGHT FIXTURE WIRING TAP DETAIL
<br />SUPPORT FROM FIXTURE BODY
<br />( NOT Y BAR SYSTEM ) TO
<br />STRUCTURE, FOUR TIE WIRES
<br />PER FIXTURE ( NOT TO EXCEED
<br />45° IN OPPOSING DIRECTION
<br />'T' BAR SUPPORTED HANGS FIXTURES WITH
<br />INDEPENDENTLY OF FOUR TIE WIRES TO
<br />FIXTURE ROOF PURLIN
<br />RECESSED LAY -IN FIXTURE
<br />X T
<br />SURFACE MOUNTED FIXTURE
<br />ON LAY - IN CEILING
<br />HANG FIXTURE W
<br />WIRES TO BAR J
<br />BOLTS IN CONC.
<br />BOX
<br />JUNCTION BOX
<br />( 2 PER BOX)
<br />FOUR TIE
<br />T OR EYE
<br />DOR ABOVE
<br />NOTE:
<br />12 GA. WIRE TIES
<br />JUNCTION BOX SUPPORTS TIED
<br />UNISTRUT FRAMING t ANCHORED
<br />INDEPENDENTYL TO CEILING " T "
<br />BARS
<br />ELECTRICAL CONSTRUCTION NOTES
<br />1 ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC. ) LATEST ADDITION,
<br />AND APPLICABLE STATE AND LOCAL ORDINANCES, EACH PIECE OF ELECTRICAL EQUIPMENT INSTALLED
<br />SHALL BEAR A U.L. LABEL. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH THE OCCUPATIONAL
<br />SAFETY AND HEALTH ACT ( OSHA ) LATEST EDITION.
<br />2 THE ELECTRICAL CONTRACTOR SHALL ARRANGE AND PAY FOR ALL PERMITS, FEES, INSPECTIONS, ETC.,
<br />AND CARRY ALL INSURANCE AS REQUIRED BY LAW PRIOR TO STARTING CONSTRUCTION.
<br />3 THE ELECTRICAL CONTRACTOR SMALL PROVIDE ALL NECESSARY LABOR, MATERIALS, TRANSPORTATION,
<br />RIGGING, TOOLS, STORAGE, ETC., FOR ALL WORK INDICATED AND REQUIRED FOR A COMPLETE INSTALLATION.
<br />4 THE ELECTRICAL WORK SHALL INCLUDE COMPLETE TESTING OF ALL EQUIPMENT AND WIRING. WORKMANSHIP
<br />SMALL BE OF THE HIGHEST QUALITY AS ESTABLISHED BY TRADE STANDARDS.
<br />5 ELECTRICAL CONTRACTOR SMALL KEEP A MASTER SET OF PLANS THAT ARE TO BE MARKED UP
<br />TO REFLECT "AS BUILT" CONDITIONS ON A DAILY BASIS. THESE "AS BUILT" MARK UPS MAY BE REVIEWED
<br />BY THE ARCHITECT, ENGINEER OR OWNER'S REPRESENTATIVE, AT THEIR REQUEST WITHOUT PRIOR NOTIFICATION,
<br />THESE "AS BUILT" MARK UPS WILL BE REVIEWED BY THE ENGINEER AND TURNED OVER TO THE OWNER AT
<br />THE CONCLUSION OF THE PROJECT,
<br />6 THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COMMUNICATION WITH THE LOCAL BUILDING
<br />DEPARTMENT AND INSPECTION PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION.
<br />1 THE OWNER WILL NOT BE HELD LIABLE FOR FIELD CHANGES THAT ARISE FROM CONTRACTOR ERROR OR
<br />OMISSIONS OF MATERIALS OR WORKMANSHIP IN WORK PERFORMANCE.
<br />8 THE ELECTRICAL CONTRACTOR SMALL MAKE ALL NECESSARY ARRANGEMENTS WITH THE LOCAL POWER
<br />COMPANY FOR SERVICES AND SMALL BE RESPONSIBLE FOR VERIFICATION OF ALL UTILITIES AND THE
<br />PLACEMENT LOCATIONS OF THE ELECTRICAL SERVICE AND EQUIPMENT. THE ELECTRICAL CONTRACTOR
<br />SMALL PAY AL NECESSAY CHARGES TO THE POWER COMPANY PRIOR TO CONSTRUCTION.
<br />9 AL ELECTRICAL EQUIPMENT, MATERIAL, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF
<br />ONE ( 1 ) YEAR FROM DATE OF ACCEPTANCE.
<br />10 IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY, AND SHOULD NOT BE SCALED. COORDINATE
<br />ALL ELECTRICAL WORK WITH OTHER TRADES, ( PLUMBING , HVAC, ETC. ) SO AS NOT TO CONFLICT IN
<br />LOCATION OF PERFORMANCE OF OTHER SYSTEMS.
<br />11 NECESSARY, OBVIOUSLY REQUIRED ELECTRICAL ITEMS THAT ARE NOT SHOWN ON THE DRAWINGS, DOES NOT
<br />RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY TO INSTALL A COMPLETE AND SAFE ELECTRICAL SYSTEM
<br />12 THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES SO THAT INTERFERENCES BETWEEN
<br />CONDUITS, RACEWAYS, DUCTS, PIPING: AND STRUCTURAL MEMBERS WILL BE AVOIDED.
<br />13 THE ELECTRICAL CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT ALL WIRINGS IN ACCORDANCE WITH
<br />THE WIRING DIAGRAMS FOR POWER AND CONTROL OF ALL AIR CONDITIONINGS, HEATING AND VENTILATING
<br />EQUIPMENT AS PROVIDED BY THE HVAC CONTRACTOR.
<br />14 WIRE AND CABLE SHALL BE 600 VOLT MINIMUM AWG 012. ALL WIRING SHALL BE TYPE TW, THW OR THHN AS
<br />NECESSARY TO MEET ALL APPLICABLE CODES.
<br />15 AL WIRE AND CABLE SHALL BE IN CONDUIT, MINIMUM SIZE 1/2" WITH LARGER SIZES AS INDICATED OR
<br />REQUIRED BY NEC. ALL SERVICE AND PANELBOARD FEEDER CONDUITS, CONDUITS IN OR BELOW FLOOR,
<br />IN DAMP AND WET LOCATIONS, IN CONCRETE AND LARGER THAN TWO INCHES SHALL BE RIGID
<br />GALVENIZED STEEL.
<br />AL CONDUCTORS, UNLESS OTHERWISE NOTED, SMALL BE COPPER RUN IN APPROVED METAL RACEWAY.
<br />METAL RACEWAY PENETRATING FLOORS AND FIRE RATED PARTITIONS SHALL BE SEALED AIR TIGHT WITH
<br />MATERIAL RATED EQUAL TO THE PENETRATED MATERIAL,
<br />FURNISH AND INSTALL ALL BRANCH CIRCUITS. CIRCUITS SMALL BE •12 WIRE IN 1/2" CONDUIT UNLESS
<br />OTHERWISE NOTED, THESE ARE MINIMUM WIRE AND CONDUIT SIZES, ALL WIRE SHALL BE COPPER, NO
<br />ALUMINUM CONDUCTORS WILL BE PERMITTED.
<br />16 ALL NEW RACEWAYS/CONDUITS SHALL BE METALLIC MINIMUM SIZE 1/2", SUPPORTED AT INTERVALS NOT TO
<br />EXCEED EIGHT l 8 ) FEET: ALL FITTINGS SHALL BE COMPRESSION TYPE, NO SETSCREW TYPE FITTINGS WILL
<br />BE PERMITTED,
<br />11 IN NO CASE MAY EMT OR FLEXIBLE CONDUIT BE RUN FROM FIXTURE TO FIXTURE WITHOUT THE USE OF OUTLET
<br />BOXES.
<br />IS FLEXIBLE CONDUIT CAN ONLY BE USED FOR SHORT ( MAXIMUM SIX FEET ) FINAL CONNECTIONS TO INTERIOR
<br />LIGHTING FIXTURES AND EQUIPMENT.
<br />19 THE ELECTRICAL CONTRACTOR SHALL FOLLOW THE SAME COLOR CODE IDENTIFICATION FOR EACH PHASE
<br />THROUGHOUT THE SYSTEM FROM SERVICE SWITCH OR TRANSFORMER THROUGH ALL BRANCH CIRCUITS,
<br />20 AL SLAB OR ROOF PENETRATIONS SHALL BE WITH APPROVED FIRE RATED AND SMOKE BARRIER FITTINGS.
<br />PROVIDE ACCESSORIES ( PITCH POCKET, CONCRETE, ETC. ) AS REQUIRED.
<br />21 ALL CONDUITS SHALL BE RUN CONCEALED WHERE POSSIBLE. EXPOSED CONDUITS SHALL BE RUN PARALLEL
<br />AND /OR PERPENDICULAR TO BUILDING CONSTRUCTION.
<br />22 CONDUIT MAY NOT BE RUN IN DUCTWORK.
<br />23 THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTAL A 3/4" EMPTY CONDUIT FROM EACH TELEPHONE
<br />OUTLET TO THE OWNER'S TELEPHONE BOARD, WITH PULL WIRE. PROVIDE ALL REQUIRED CONDUIT FROM
<br />OWNER'S TELEPHONE BOARD TO BUILDINGS TELEPHONE ROOM, PROVIDE PULL BOXES AND PULL WIRE AS
<br />REQUIRED, VERIFY EXACT LOCATIONS OF EXISTING TELEPHONE SERVICE AND CONDUITS. COORDINATE ALL
<br />WORK WITH OTHERS TRADES AND TELEPHONE COMPANY.
<br />24 THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTAL ALL CONDUIT, BOXES, FITTINGS, PULL WIRE, ETC.
<br />REQUIRED FOR AL MISCELLANEOUS SYSTEMS PER OWNER'S REQUIREMENTS. COORDINATE EXACT LOCATIONS
<br />AND REQUIREMENTS WITM OWNER.
<br />25 ALL COMMUNICATION AND CONTROL WIRING SHALL BE IN CONDUIT,
<br />26 FURNISH AND INSTALL PANEL BOARDS OF AMPACITIES SHOWN ON PLANS. PANELS SHALL BE CIRCUIT BREAKER
<br />TYPE, WITM MAIN LUGS AND BRANCH CIRCUIT BREAKERS AS SCHEDULED. AL ELECTRICAL PANELS AND
<br />EQUIPMENT SHALL BE U,L. LISTED AND APPROVED FOR SUCH USE, PANELS SHALL BE BOLT —ON TYPE AS
<br />MANUFACTURED BY SQUARE 'D' OR APPROVED EQUAL.
<br />21 ALL EQUIPMENT SMALL BE PROPERLY GROUNDED IN ALL RACEWAYS, BRANCH CIRCUITS t FEEDERS,
<br />PER LOCAL ELECTRICAL CODES AND THE NEC.
<br />28 THE ELECTRCIAL CONTRACTOR SHALL COORDINATE ALL RECEPTACLE AND OUTLET LOCATIONS WITH
<br />ARCHITECTURAL DRAWINGS AND GENERAL CONTRACTOR BEFORE ROUGH IN.
<br />29 ALL LIGHTING FIXTURES SHALL BE SELECTED BY THE OWNER AND INSTALLED BY THE ELECTRICAL
<br />CONTRACTOR. ( LIGHTING FIXTURES INDICATED ON DRAWINGS AND SCHEDULES ARE FOR REFERENCE
<br />ONLY. FIXTURES OF EQUAL QUALITY MAY BE USED AS DIRECTED.
<br />30 ALL TEMPORARY ELECTRICAL SERVICE REQUIRED FOR CONSTRUCTION SHALL BE FURNISHED BY THE
<br />ELECTRICAL CONTRACTOR. FOLLOWING CONSTRUCTION AL TEMPORARY WIRINGS AND EQUIPMENT SHALL
<br />BE REMOVED WHEN DIRECTED BY THE GENERAL CONTRACTOR. ELECTRIC OUTLETS, CORDS, LIGHTS,
<br />LIGHTING LEVELS, ETC., SMALL CONFORM TO O.S.H.A. AND LOCAL ORDINANCES.
<br />31 ALL ELECTRICAL EQUIPMENT EXPOSED TO WEATHER SMALL BE WEATHERPROOF AND ALL CONDUIT
<br />EXPOSED TO WEATHER SMALL BE HEAVY WALL GALVANIZED STEEL.
<br />32 SUBMIT SIX COMPLETE COPIES OF SHOP DRAWINGS AND PRODUCT DATA FOR LIGHTING FIXTURES,
<br />ELECTRICAL PANELS, SERVICE EQUIPMENT, WIRING DEVICES AND DISCONNECT SWITCHES,
<br />U
<br />Z
<br />Lu
<br />N
<br />0-
<br />Lu
<br />— O
<br />cri
<br />� o
<br />U
<br />U d�
<br />N cq
<br />LLkw�)
<br />(p .4
<br />0�
<br />Q
<br />l--1
<br />ENGINEERING
<br />Lu
<br />O
<br />Lu
<br />� cr ,i 0
<br />Z:3
<br />0
<br />Lu
<br />�Jr
<br />L
<br />f LL � N
<br />ENGINEERS SEAL
<br />101
<br />SHEET
<br />ROOM ADDITION
<br />DRAWING SETS
<br />SHEET NUMBER
<br />r= 2
<br />Da.iger:
<br />CRC
<br />Prom Hy:
<br />
|