O O <br />(E)CU-1 (E)CU-2 11 <br />® ® a (E)CU <br />LVR O7 <br />s---1, <br />00 <br />r <br />o00 EXAM 190-CFM (E)AHU 11 I <br />O8o0 106 O RGC -10X 10 } <br />-_. <br />O UTILITY BALANCE TO <br />1(E)AHU-1 <br />4 105 <br />200-CFM <br />co I O <br />13 OT <br />BALANCE TO <br />200-CFM <br />EXAM <br />104 <br />O o"o <br />190-CFM <br />RGC-i0X10 <br />a <br />BALANCE TO 0 0-0 <br />200-CFM 190-CFM <br />RGC-10X 10 <br />EXAM <br />103 <br />O <br />BALANCE TO ( 010 <br />200-CFM 190-CFM <br />RGC-10X 10 <br />EXAM <br />102 e <br />O N <br />BALANCE TO <br />25-CFM <br />TOILET <br />101 <br />10 <br />0 <br />0 <br />18" 0 <br />BALANCE TO <br />150-CFM <br />LAB <br />107 O <br />10 "o <br />RGC 10X 10 <br />O BALANCE TO <br />100-CFM HALL <br />BALANCE TO O 2s, 121 <br />100-CFM <br />200-CFM <br />RGC-12X12 <br />EXAM <br />120 <br />3UU—VF iVl <br />RGC-14X14 <br />O <br />BALANCE TO <br />125-CFM <br />(D <br />BALANCE TO <br />125-CFM <br />O LOBBY <br />100 <br />BALANCE TO <br />15-CF <br />0 <br />MECHANICAL CEILING PLAN <br />NOTE TO CONTRACTOR <br />ON EXISTING CONDITIONS: <br />1 <br />CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID <br />AND SURVEY ALL EXISTING CONDITIONS AND <br />EQUIPMENT PRIOR TO SUBMITTING BID FOR WORK <br />REQUIRED BY THESE DOCUMENTS. THIS <br />INCLUDES ABOVE THE CEILING AND ON TOP OF <br />THE ROOF. <br />2. <br />CONTRACTOR SHALL REFER TO AND READ <br />THROUGH ALL OF THE "CONTRACTOR'S SCOPE OF <br />WORK" AS DEFINED IN THE BID SPECIFICATIONS <br />AND DOCUMENTS AS PART OF THE BID PROCESS. <br />3. <br />1F AT ANY TIME. THERE IS DISCREPANCY BETWEEN <br />THE PLANS & SPECS. OR CONFUSION/CONCERN <br />OVER REQUIRED WORK, CONTRACTOR SHALL <br />IMMEDIATELY NOTIFY ARCHITECT. ENGINEER. &/OR <br />OWNER AND GET DIRECTION BEFORE PROCEEDING <br />WITH WORK IN QUESTION. <br />4. <br />FOR ALL EXISTING EQUIPMENT TO BE <br />RE —LOCATED &/OR RE —USED, CONTRACTOR <br />SHALL BE RESPONSIBLE FOR DISCONNECTION, <br />SAFE STORAGE, & RE —CONNECTION OF SAID <br />EQUIPMENT COMPLETELY. <br />5. <br />FOR ALL EXISTING EQUIPMENT TO BE <br />DEMOLISHED (I.E. DEMO) CONTRACTOR SHALL BE <br />RESPONSIBLE FOR DISCONNECTION, REMOVAL, & <br />DISPOSAL OFF —SITE PER CODE, OF SAID <br />EQUIPMENT COMPLETELY. <br />0 <br />BALANCE TO <br />225-CFM <br />215-CFM <br />RGC-10X 10 <br />BREAKROOM <br />108 <br />1 <br />8"0 O <br />65—CFM SUPPLIES BALANCE TO <br />RGC-10X10 109 75—CFM <br />10 10 <br />TOILET TOILET <br />110 1w 111 <br />0 <br />B TO BALANCE TO <br />25-CFM 25-CFM <br />140-CFM <br />RGC- l OX 10 <br />10" o M 1O5 DOCTOR OFFICE <br />112 <br />O BALANCE TO <br />150-CFM <br />i <br />+------=mow <br />I <br />1z /j <br />i` <br />I <br />I I <br />SUPPLIES <br />15 <br />113 i <br />CD2-8 _..____..._._.__.. <br />100-CFM <br />NURSE <br />113 <br />I <br />J,NO) 1O BALANCE TO <br />200-CFM <br />190-CFM <br />RGC-10X 10 <br />PROVIDER OFFICE `--� <br />15 <br />HVAC LEGEND <br />SUPPLY AIR DIFFUSER OR GRILLE <br />RETURN/EXH. AIR REGISTER OR GRILLE <br />NEW DUCTWORK, WITH SIZE LISTED <br />^lam <br />FLEXIBLE DUCT <br />SD <br />DUCT SMOKE DETECTOR <br />OT <br />THERMOSTAT BASE <br />�-�- <br />AIRFLOW DIRECTION <br />- <br />1" DOOR UNDERCUT <br />0 <br />ROUND, DIAMETER <br />AFF <br />ABOVE FINISHED FLOOR <br />CFM <br />CUBIC FEET PER MINUTE <br />TYP <br />TYPICAL - ITEM OR METHOD <br />GRAVITY BACK -DRAFT DAMPER <br />VID / L— <br />MANUAL VOLUME DAMPER (W/HANDLE) <br />SUPPLY DUCT TAKE -OFF WITH VD <br />(N) <br />NEW <br />(E) <br />EXISTING <br />­�* <br />CONNECT NEW TO EXISTING <br />DIFFUSER TAG EQUIPMENT TAG <br />AIRFLOW EQUIPMENT <br />400 CFM RTU�TMPE <br />CD-12"0 EQUIPMENT <br />MARK SIZE <br />-NECK NUMBER <br />KEY NOTES ON REMODEL PLAN: <br />O1 RELOCATE DIFFUSER AND BALANCE AS SHOWN. <br />EXTEND/SHORTEN DUCT AS NECESSARY. <br />O REPLACE DIFFUSER WITH NEW DIFFUSER (CD), RELOCATE, AND <br />BALANCE AS SHOWN. <br />O3 ALL EXISTING SUPPLY DIFFUSERS NOT OTHERWISE NOTED ARE <br />EXISTING TO REMAIN. BALANCE AS SHOWN (TYPICAL) <br />O4 INSTALL NEW RETURN GRILL (RGC2), BALANCE AS SHOWN, <br />AND DUCT BACK TO AIR HANDLING CLOSET. <br />O5 INSTALL NEW RETURN GRILL (RGC), BALANCE AS SHOWN, AND <br />DUCT BACK TO AIR HANDLING CLOSET. <br />© INSTALL NEW RETURN GRILL (RGC2) OPEN TO PLENUM <br />CLOSET. <br />O7 INSTALL NEW FRESH AIR LOUVER WITH 18X18 PLENUM <br />(8"AFF). <br />® ROUTE 10"0 FRESH AIR DUCT TO (E)AHU NEW RETURN <br />PLENUM WITH VOLUME DAMPER AND BACKDRAFT DAMPER. <br />O9 (E)AHU TO HAVE NEW RETURN AIR PLENUM WITH FILTER SLOT <br />AND RETURN GRILLE INSTALLED BENEATH UNIT. SERVICE AND <br />BALANCE (E)AHU & (E)CU PER SERVICE NOTES. <br />10 ALL EXISTING RESTROOM EXHAUST SYSTEMS TO REMAIN. <br />11 EXISTING DEDICATED LAB WALL MOUNTED AHU AND <br />ASSOCIATED CONDENSING UNIT TO REMAIN. <br />12 EXISTING LOUVERS IN WALL AND DOOR TO REMAIN. <br />13 REPLACE THERMOSTAT WITH NEW. <br />14 EXISTING DUCT SMOKE DETECTOR IN SUPPLY TO REMAIN. <br />15 INSTALL NEW SUPPLY DIFFUSER. <br />' C�E•N <br />No 56189 <br />=,lf' STATE OF <br />O R <br />oe <br />NA� % <br />J)S I ANEK- LLVV <br />AND ASSOCIATES <br />2257 TWELVE OAKS WAY, SUITE 103 <br />WESLEY CHAPEL, FL 33544 <br />PH (813) 991-1248 <br />CERT. AUTH. # 8397 a-si <br />THE <br />L U N Z <br />uKCiUP <br />585 Main Street, Suite 201 <br />Dunedin, FI 34698 <br />p 727.733.9400 <br />f 727.733,9555 <br />lic. AAC001580 <br />lunz.com <br />w � <br />z - «. <br />W < X <br />U w <br />:D coof <br />O o <br />F- <br />z W <br />O r¢ <br />U .. <br />c z <br />x <br />a <br />0 <br />W <br />Z cn <br />(V <br />�cn <br />W J <br />> U_ <br />REVISION,j . . <br />REVISION. -- <br />REVISIONQ • -- <br />ISSUED FOR CONSTRUCTION: -- <br />ISSUED FOR PERMIT: 09.05.18 <br />SSUED FOR BID: -- <br />ISSUED FOR APPROVAL: -- <br />DRAWN BY: T.J. <br />REVIEW BY: M. LENS <br />THE LUNZ GROUP <br />©COPYRIGHT 2018 ALL RIGHTS RESERVED <br />1812.01 <br />M-101 <br />SCALE: 1l4" = 1'-0" <br />MATTHEW D. LEWIS, P.E. FL LIC#56189 <br />