A/C <br />DIS( <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATIONS A & B <br />1/411 = 1 1-011 <br />LEC <br />IETER <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST TFROM BATH DOOR AND AT <br />LEAST 6'FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LA rEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED Wt <br />EDGE OF <br />SWITCH--,,_ <br />SWITCH— - U <br />4 1/2" <br />DUPLEX <br />DOOR JAMB -----A <br />OUTLET <br />TRIM-` <br />BASE ---- <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />z <br />C—'SMOKE DETECTOR <br />1 1-011 <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />E)= 11 OV DUPLEX OUTLET AT 12" <br />11 OV DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />11 OV DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />11 OV DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 11 OV DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />11 OV QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />11 OV DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br /><6> STRUCTURED WIRE OUTLET <br />-69- SWITCH AT 36" <br />M <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />CLG MINIT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />WALL MNT FIXTURE NOTE: <br />0 40W A 6" ROUND OPALEX - ALTERNATE <br />3 TUB/SHOWER CANS MAY BE <br />04 5OW PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />06 50W MR1 6 4" LOW VOLTAGE OWNER <br />08 50W PAR20 NFL 4" MINI ROUND RECESS <br />010 5OW PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />Cos COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />0S SMOKE DETECTOR <br />cU-182 UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />-D-24- DOUBLE 24" FLUOR STRIP <br />= U-36 UNDER CABINET 36" <br />—S-36— SINGLE 36" FLUOR STRIP <br />— D-36 — DOUBLE 36" FLUOR STRIP <br />—S-48— SINGLE 48" FLUOR STRIP <br />— D-48 DOUBLE 48" FLUOR STRIP <br />24"CLG MNT WRAPPED FLUOR LIGHT <br />1 48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF 24 7M 24" VANITY LIGHTING <br />5�-mF 36:;;R 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />EXHAUSTFAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />IIII&J ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />EM A/C REGISTER <br />(Z) THERMOSTAT <br />021 SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY NTH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />(I) LO <br />0 0 <br />'0 q U <br />C) C") �! 4) <br />Cn co <br />4— <br />E <br />5 0 <br />0 LL <br />U <br />U LU -C� C <br />00 E �2 <br />70 <br />0 000 <br />0 CL <br />w <br />w <br />Ld (6 w 0 <br />uj P LU -j w 2 0 <br />W8< <'M;� z <br />0 0 -j 0 <br />< <br />L) <br />Cn w <br />b < Z LL OZMOOF--j <br />J 2 <br />awxmo t2oom <br />W-z Lurnx <br />LL <br />z I � <br />5 2 <br />0 <br />U) 0 <br />0 <br />z <br />U)w IL U) W LLI �- z LL W < <br />-j IL Z �d 0 0 w <br />W <br />V5 z w z <br />0 Ix <br />LL <br />0 LU M F- W <br />w z 3 <br />< <br />0 =) <br />LL < 0 < LL <br />0 <br />C:) <br />z 04 <br />w <br />0 <br />too <br />z <br />cy) 0 <br />< U) CY) r4l__ <br />LO <br />U) <br />LL <br />U) <br />z <br />w < Lq <br />00 <br />< < <br />Z 0 <br />3: <br />LUz <br />L.Li <br />C:) <br />(0 <br />C) <br />co <br />0 <br />C5 <br />co <br />C', <br />N <br />'N <br />'N <br />0 <br />0 <br />C3 <br />a <br />a <br />a <br />0 <br />N <br />U-) <br />>w <br />Cj <br />'-i <br />'q: <br />0 <br />6 <br />CD <br />'6 <br />LO <br />qq <br />00 <br />>- <br />Z <br />(cy, <br />Z <br />LU <br />C) <br />LU <br />z W <br />ozz <br />0 <br />LLJ 0 0 <br />00V5 <br />Lo <br />0 <br />p z 5; <br />CLUO <br />0�< <br />Z <br />Lr) <br />of <br />W F- <br />W r <br />w <br />Lf) <br />0 <br />In �t <br />F- 1,- 2 <br />0=)O <br />ZOM <br />LU <br />00 <br />0 <br />zwo <br />C) <br />< <br />0 <br />:5ww <br />Z LL <br />z <br />(1)z <br />3e. <br />L) <br />z <br />:5 <br />F- <br />0 <br />0 <br />0- <br />z <br />A6.1 <br />z <br />z <br />w <br />LU(:;) <br />>(=) <br />LAST PLOT DATE <br />. . <br />ApH14,2023 <br />z <br />0 <br />1 ST FLOOR <br />ELECTRICAL PLAN <br />