ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08. 250.94 --/ <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />upper to lights a outlets <br />3pper to 20 amp ckts <br />copper 10 WH <br />cropper to Dryer <br />Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle Installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range Is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />j4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />®l <br />/ <br />RECESSED LIGHT FIXTURE <br />{ P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />—� <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />[CHl <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />LD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />TVI2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />C' / <br />THERMOSTAT <br />101 <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />(� <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />� J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />Tt <br />2' <br />p1, <br />_hl- <br />1 2" VTR I <br />I � <br />I <br />Will. <br />"t <br />LAV. <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />SWITCH FOR <br />WP DISPOSAL IN CAB. <br />GFiQ UNDER SINK <br />I <br />3 J i Lt_// <br />CC ° I <br />I <br />RC UGH -IN <br />FOR OPT. GF' <br />KITCHEN 2X4FL. FA/LIGHT I <br />6GFI GFI( I <br />I <br />G4 <br />OPTIONAL LIGHTING_ <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />IRRIGATION GFI <br />@ 44" A.F.F. <br />AC PAD <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />St <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />FLOOR ELECTRICAL PLAN <br />U' V <br />Z <br />Z <br />Z <br />Q <br />J <br />a <br />a) ( <br />4--r cn <br />w <br />�U — <br />O LI <br />Ln (A _ <br />E <br />1 o <br />u <br />w <br />C <br />-Z <br />mCm, <br />W <br />W®_$ILL <br />Qao <br />A <br />B D. <br />r` <br />chi <br />4 <br />jq <br />oc aco ow <br />CL <br />�Z02 <br />- <br />45 <br />IL 3 Z11 . <br />m <br />a� <br />oa <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />1 <br />O <br />Z N <br />0 + � <br />.4 <br />�(nM0 <br />M <br />cDLn <br />Z <br />4)0Ln <br />aL� <br />F"- n' • f j <br />�j a <br />00 <br />00 <br />W <br />E <br />My <br />Z <br />J <br />J <br />Z <br />100 <br />O� �aV <br />Z>Q-�l <br />�Z <br />�gZ <br />O <br />Ln <br />N <br />Ln <br />rl <br />O <br />a <br />Z <br />Q Z <br />flH <br />gffl� <br />�y <br />W <br />zLIj E <br />~�5 <br />,--ll U <br />1"'ll <br />o <br />o Ld <br />O <br />W <br />Z <br />W <br />O1 <br />M U <br />.. W <br />J <br />W <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />1122 <br />JOB NO: 17-4137 <br />SHEET NO. <br />5 <br />