Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />i <br />i <br />i <br />.--`-------------------------------i <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan Is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be In accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Proteatlon: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where Installed <br />within 6' if the outside edge of a sink. This would Include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. WEATHERPROOF DUPLEX OUTLET <br />- G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />0 <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />—� <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />0 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM� SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�] <br />ELECTRIC METER <br />WWI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />(� SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />J OPT. CEILING FAN <br />(7) (1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />CENTER <br />METER <br />MAIN <br />O <br />200amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING Q <br />TERMINATION PER �f <br />NEC 08, 250.94 J <br />NEMA1 <br />200 AMP <br />—i#14 copper to lights& outlets F-------------------------------------- <br />------------------------------------------- <br />-� #12 copper to 20 amp tuts I I <br />—♦ #10.2 copper to WH I <br />I <br />copper to Dryer <br />I <br />or 4/0 SER Alu i <br />I I <br />I I <br />I <br />I I <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />INOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE I <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />----------------------------------j <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2nd FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />0 in <br />,r <br />Z <br />Z <br />Z <br />Q <br />(D <br />a. <br />U, Z <br />L10 0 <br />i--r cn <br />w <br />Q <br />eU — <br />0 w <br />F' <br />L 1 <br />Vi = <br />TC ~ <br />o <br />m <br />M <br />w <br />8 <br />c to <br />0 L9 <br />' = <br />.00 <br />Q a <br />d <br />A' <br />B D. <br />Nc n�oc <br />ti <br />o <br />in <br />rn <br />�o <br />�- <br />N <br />m <br />r IL e- O <br />Wit <br />W4 <br />10ZW V a ii.- <br />as <br />�g? <br />t9 H <br />W <br />m <br />N (J <br />- <br />V 12 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />1 <br />O <br />O <br />Z ItV <br />0 n <br />� M O <br />M <br />Q m Ln <br />to :2 v <br />is <br />0 <br />QL_ LA <br />a ,^ <br />M <br />Q � <br />3i ra <br />Z <br />W <br />_j0 <br />6E <br />z�a <br />�z ~z <br />io �t <br />M <br />M <br />O <br />ri <br />In <br />N <br />rIn <br />'i <br />ova <br />o <br />Q <br />Z <br />,-�z <br />�gg <br />�� �� <br />M ni <br />fC <br />CL <br />w <br />J <br />F— _j <br />Q$ <br />� s <br />'—i U <br />6 <br />L.J.. <br />Zs <br />-i ° W <br />o <br />M V~ <br />Z <br />W <br />.. L <br />LIJ <br />Z <br />a LU <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />1122 <br />JOB NO: 17-4137 <br />SHEET NO. <br />6 <br />