I)ocuSlgn Envelope ID: OOCCED92-FD82-41DF-BBOB-9A1B2DCB5D17 <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDC <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/s' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVET <br />FLUSH w/ 3000psi CONCRETE. <br />EXISTING FOUNDATION. <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />:o: <br />D � <br />D <br />D EXISTING FOUNDATION <br />D � <br />C D <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />—d — — — — — — (MAX 20" <br />° 4 ° ° e I DEEP) <br />4" <br />/K 4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL <br />16" UNDER 2 STORY WALL <br />VAPOR BARRIER <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />n <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />8" CMU CHAIR BLOCK W/ (1) #5 ---\ <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />MONO LITHIC SLAB <br />MIN 24" LAP <br />) DEGREE <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />° <br />OR FIBER MESH <br />� � <br />° <br />° 4 << A a <br />#4OR#5 <br />O <br />, , ; ° <br />REINFORCING PER <br />Z <br />a <br />° <br />MONOLITHIC FOOTING <br />M d� <br />SECTION <br />°° <br />° <br />° ° ° <br />FOOTING TO BEAR ON FIRM <br />• <br />°, ° <br />UNDISTURBED SOIL <br />MINI 12" <br />°• <br />LOCATE VERTICAL <br />REINFORCEMENT IN LAST <br />STEMWALL CELL <br />• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHW TRANSITION ZONE <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ - <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />— 8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />— — — — — — — LJ <br />J <br />Q � O <br />VAPOR BAR RIER wo x <br />#4 OR #5 VERT REINFORCING/ //\\ <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C.\�/� �/ - f /\/ z/ , <br />FOOTING TO BEAR ON FIRM ADDITIONAL #4 OR `\/ //�\ \ #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A. F. F <br />(BEYOND) <br />FLOATING CONCRETE w_ <br />SLAB W/ 6x6 W1.4xW1.4 <br />WWF OR FIBERMESH > <br />#4 OR #5 VERT REINFORCING - <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />I <br />FOOTING TO BEAR ON FIRM ' <br />UNDISTURBED SOIL -- ADDITIONAL 44 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />07 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />FINISH <br />GRADE <br />(1) #4 OR #5 CONT:- <br />VARIES PER <br />36" MAX <br />ARCH PLANS <br />12" IN \` <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />3'/2' CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM <br />24" (1) #4 OR #5 90' BEND @ 48" O.C. <br />d ° <br />° <br />VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />_�' • \ <br />UNDISTURBED SOIL <br />b <br />12" UNDER 1 STORY WALL W/ (2) <br />ADDITIONAL NO.4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ (3) <br />#4 OR (2) #5 CONT I <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />'NOTE': IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />VAPOR BARRIER <br />n n <br />SEE NOTES (MAX 16") U <br />6 <br />STUCCO OR DIRECTLY ADHERED cli <br />STONE CLADDING FINISH - MIN 6" rn <br />0 <br />N go/\ <br />ALL OTHER EXTERIOR WALL <br />CLADDING - MIN 8", U.N.O. ON ARCH <br />O <br />O <br />- <br />p <br />\//\\\�\\�/\�� <br />� <br />PEX0 <br />12" MIN / <br />CV <br />U <br />FOOTING TO BEAR ON / 6" OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBED <br />SOIL LOCATIONS ON FND PLAN <br />� <br />N <br />M <br />12" UNDER 1 STORY WALL w/ <br />IIII <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 <br />_ <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ <br />W <br />tds <br />(2) #5 OR (3) #4 CONTINUOUS <br />J <br />z <br />true design studios <br />MONOLITHIC FOOTING SECTION <br />1 CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />0 <br />FOLLOWING OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />Y <br />U <br />9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY <br />O <br />PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. <br />O <br />O <br />.- <br />CONCRETE SLAB w/ 6x6 <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR <br />w <br />C <br />FIBERMESH <br />RRN <br />CO) <br />a ° 00 <br />16" VAPOR BARRIER Q ►-• <br />3 BEARING WALL FOOTING SECTION Z <br />w <br />w <br />CONCRETE SLAB W/ 6x6 w <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />- 0'-0" A.F.F. O <br />° SEE ARCH <br />a \° DETAILS <br />° a ti <br />8" M I N <br />\\, Z w <br />8"x8" THICKENED 8" U) <br />W U_ <br />FTG AT w <br />STEP-DOWN, SEE VAPOR BARRIER Z <br />PLAN W J Z w <br />4 CURB STEP SECTION m Uj O U) <br />- w p G <br />8" UNDER MASONRY WALL Z <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL Z <br />w M w Q Q <br />_� -- -- - W o <br />6x6W1.4xW1.4WWF 1 w W <br />OR FIBERMESH VARIES j Q W <br />t SEE ARCH <br />a ° (MAX 16") w <br />0 X <br />/Xxxx12" M I N\\/\� Z <br />0 Z <br />VAPOR BARRIER \/� ° n ///j // O <br />\\ W <br />6" OPT, EXTENSION IN BRICK 0 H <br />LOCATIONS ON FND PLAN d Z <br />12" UNDER 1 STORY WALL w/ O i1 <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 U LL. <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ Q w <br />(2) #5 OR (3) #4 CONTINUOUS ABBOTT PARK Q <br />GARAGE EXT WALL CURB SECTION U_ - 0 <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Q LOT 012-03 w <br />FOLLOWING OCCUR - - <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U Z <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY C7 <br />PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. U' PROJECT NO W <br />CONCRETE SLAB W/ 6x6 O 2021.006616 LL <br />W1.4 x W1.4 WWF OR O 0 <br />FIBERMESH Z <br />DRAWN: <br />0'-0" A.F.F. SEE ARCH = KME <br />(MAX 20" O <br />4 ° n DEEP) F CHKD: <br />\ <br />4 ° e (i1 \//\\//\\ \ o — — — w MJP w <br />\/\ a • e 4" w J <br />4" EXTENSION X U <br />UNDER BRICK VENEER < ``����N LA,�� U) <br />12" UNDER 1 STORY WALL } ���J5• C,E N N/:�'�,��i <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER Q ` .' �,� `SF % >Z_ <br />16" UNDER 2 STORY WALL No 85166 > <br />W <br />W/ (3) #4 OR (2) #5 CONT Z 'k =• Doe igned by: •' * _ <br />BEARING CURB STEP SECTION �'•.-3F46}4DA�°OEFa35,''444/ <br />1/ <br />TYPICAL REINFORCING <br />FARS AT <br />OOTING,, S EKENED PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />I <br />IL— — — — — — — — — -- <br />rHOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />Z �''� S��NA1 %% .%%% 3: <br />O 05-17-2021 Q <br />I' W <br />U REVISIONS: _ <br />LL - - - <br />Q No. Descri_p_tion Date w <br />U) J <br />O f-- <br />O Z <br />Z- - - -- — Q <br />= o <br />W <br />H <br />X <br />W ST=2mD <br />11 <br />Q <br />CMUIMETAL CONNECTOR ENGINEERING <br />