DocuSign Envelope ID: 5953A008-AD2B-44CB-A263-6A20DCB735DF <br />DESIGN CRITERIA AND LOADS <br />TABLE 7: METAL CONNECTOR SCHEDULE <br />NOTES 2. 3. 4 <br />I I � <br />>O <br />w <br />O <br />N u_ w <br />Building Code <br />Florida Building and Residential Codes , <br />7ch Edition (2020) <br />Code for Desiqn Loads <br />ANSI/ASCE 7-16 <br />ROOF LOADING' ............................................... <br />Cd = 1.25 <br />TOP CHORD LIVE LOAD .................................. <br />20 PSF <br />TOP CHORD DEAD LOAD................................7 <br />PSF (TILE = 15 PSF) <br />BOTTOM CHORD LIVE LOAD <br />ATTICS WITH LIMITED STORAGE ............... <br />20 PSF <br />ATTICS WITHOUT STORAGE .......................10 <br />PSF <br />(NON -CONCURRENT) <br />BOTTOM CHORD DEAD LOAD........................5 <br />PSF <br />WIND LOADING ................................................. <br />Cd 1.60 <br />ASCE 7-16, 3S GUST........................................139 <br />MPH <br />BASIC WIND SPEED <br />EXPOSURE CATEGORY .................. ................ <br />C <br />BUILDING CATEGORY.....................................II <br />ENCLOSURE CLASSIFICATION ...................... <br />ENCLOSED <br />INTERNAL PRESSURE COEFF ........................0.18 <br />C&C DESIGN PRESSURES..............................(SEE <br />TABLE 1) <br />FLOOR LOADING .............................................. <br />Cd = 1.00 <br />TOP CHORD LIVE LOAD..................................40 <br />PSF <br />TOP CHORD DEAD LOAD................................10 <br />PSF <br />BOTTOM CHORD LIVE LOAD..........................0 <br />PSF <br />BOTTOM CHORD DEAD LOAD........................5 <br />PSF <br />SPECIAL FLOOR (GAME ROOM) LOADING .... Cd = 1.00 <br />TOP CHORD LIVE LOAD..................................60 <br />PSF <br />TOP CHORD DEAD LOAD................................10 <br />PSF <br />BOTTOM CHORD LIVE LOAD ...........................0 <br />PSF <br />BOTTOM CHORD DEAD LOAD........................5 <br />PSF <br />MAXIMUM FLOOR TRUSS SPACING ........... <br />..16" O.C. <br />DEFLECTION CRITERIA <br />LL / 240 <br />ROOF TRUSSES .............................................. <br />TL / 180 <br />TL MAX 1" UP TO 40' SPAN <br />LL / 480 <br />TL / 360 <br />OPEN WEB FLOOR TRUSSES ....................... <br />LL / 480 <br />TL/240 <br />WOOD I JOISTS ............................................... <br />TL MAX'/2' <br />LL / 360 <br />BEAMS..............................................................TL <br />/ 240 <br />NOTES: <br />1. PORCH BEAMS AND BEAMS SUPPORTING EXTERIOR WALL <br />ABOVE SHALL NOT EXCEED %" DEFLECTION <br />TABLE 1: COMPONENT AND <br />CLADDING DESIGN PRESSURES <br />WINDOWS AND DOORS <br />EFFECTIVE <br />WIND AREA <br />ZONE DESIGNATION <br />IZ - Interior Zone (psf) <br />EZ - End Zone (psf) <br />0-20 ft2 <br />+28.54 -30.96 <br />+28.54 <br />-38.22 <br />21 - 50 ft2 <br />+27.17 -29.59 <br />+27.17 <br />-35.47 <br />51 - 100 ft2 <br />+25.52 -27.94 <br />+25.52 <br />-32.17 <br />101 - 200 ft2 <br />+24.25 -26.67 <br />+24.25 <br />-29.64 <br />SOFFIT MAX PRESSURE (psf) <br />+28.6 <br />-38.3 <br />GARAGE DOOR PRESSURE <br />+21.7 <br />-24.6 <br />END ZONE KEY MAP <br />END ZONE: END ZONES SHALL BE TAKEN <br />AS THE 1 ST 4.0' PER FIGURE R301.2 (7) <br />1ST FLOOR (TYP).0 1 <br />END ZONE <br />DESIGNATION <br />TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS <br />NOTFS 14 <br />p U <br />STUCCO AND DIRECTLY <br />MIN 15/2" 32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICALLY OR (%6' 24/16 <br />w = <br />ADHERED STONE <br />INSTALLED HORIZONTALLY) W/ 8d COMMON: 6" O.C. AT PANEL EDGES, 12" O.C. IN THE <br />^ <br />W N <br />(NOTE 6) <br />FIELD. 2x4 BLOCKING IS RECOMMENDED AT UNSUPPORTED PANEL EDGES. <br />w <br />caj J Z <br />ALL OTHER VENEER <br />MIN'%z' 32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICAL OR HORIZONTAL <br />(NOTE 8) <br />W/ 8d COMMON: 6" O.C. EDGES AND FIELD UNBLOCKED HORIZONTAL PANEL EDGES) • <br />0 <br />6" O.C. AT PANEL EDGES, 6" O.C. IN FIELD (BLOCKED HORIZONTAL PANEL EDGES) <br />x (9 rn <br />TILE AND METAL ROOF <br />MIN '%32" 32/16 SPAN RATED PLYWOOD INSTALLED WITH LONG DIMENSION <br />= <br />(NOTE 7) <br />PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 4" O.C. AT PANEL EDGES AND <br />LU <br />6" O.C. IN THE FIELD <br />p un 8 <br />MIN'/,6' 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED WITH LONG DIMENSION <br />O = O <br />of to ? <br />SHINGLE ROOF <br />PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 6" O.C. AT PANEL EDGES, 6" <br />O.C. IN THE FIELD. <br />FLOOR DECK SHEATHING: <br />23/32' T&G OSB OR PLYWOOD W/ 10d COMMON: 6" O.0 AT PANEL EDGES, 12" O.C. IN THE <br />(NOTE 5) <br />FIELD. <br />MIN Y8' OSB OR PLYWOOD OR CDX INSTALLED PERPENDICULAR TO SUPPORTS W/ 8d <br />PORCH CEILING BOARD SHEATHING: <br />COMMON: 3" O.C. AT PANEL EDGES 12" O.C. IN THE FIELD OR MIN %" EXTERIOR GYPSUM <br />CEILING BOARD, FASTEN w/ 5d x 1 /" COOLER NAIL OR NO.6 x 1 /4' LONG SCREWS @ <br />4" O.C. EDGES, 8" O.C. FIELD <br />NOTES: <br />1. FOR SHEATHING THICKNESS GREATER THAN 15/32" CATEGORY, USE RSRS-03 NAILS. <br />2. COMMON NAILS IN WALL SHEATHING MAY BE SUBSTITUTED W/ 8d GALVANIZED BOX NAILS. <br />3. ZIP WALL SHEATHING IS AN ACCEPTABLE ALTERNATE FOR APA RATED WOOD STRUCTURAL PANEL. <br />4. ALL WOOD STRUCTURAL PANEL SHALL CONFORM TO THE MOST CURRENT APPLICABLE SPECIFICATION AND SUPPLEMENTS OF <br />CURRENT APPROVED APA.MANF. SPECIFICATIONS. <br />5. FLOOR FASTENERS ARE MINIMUM REQUIRED FOR DIAPHRAGM DESIGN. FOR INCREASED FLOOR PERFORMANCE AND TO <br />REDUCE SQUEAKING, RSRS-01 NAILS OR 8d SCREW NAILS ARE RECOMMENDED. <br />6. %2" 32/16 SPAN RATED OSB OR PLYWOOD WITH BLOCKED PANEL EDGES IS AN APA RECOMMENDATION PER APA TECHNICAL <br />BULLETIN Q370 WHEN STUCCO LATH IS ATTACHED DIRECTLY TO OSB OR PLYWOOD.. SHOULD BUILDER SPECIFICATIONS ALLOW, MIN <br />STRUCTURAL REQUIREMENTS ARE %6" 24/16 SPAN RATING INSTALLED HORIZONTALLY OR VERTICALLY PER FLEXIBLE VENEER WALL <br />SPECIFICATIONS. INCLUDES FULL AND PARTIAL HEIGHT VENEER APPLICATIONS. <br />7. 1/32" PLYWOOD IS A WARRANTY LIMITATION COMMON TO TILE MANUFACTURER'S MINIMUM RECOMMENDATIONS. SHOULD WARRANTY <br />AND INSTALLATION REQUIREMENTS ALLOW, 1%2" APA RATED OSB OR EQUAL MAY BE USED TO SUPPORT TILE ROOF. <br />8. WOOD STRUCTURAL PANEL MAY BE INSTALLED VERTICALLY OR HORIZONTALLY W/ UNBLOCKED HORIZONTAL PANEL EDGES. <br />9. ROOF DECK SHEATHING HAS BEEN ENGINEERED TO RESIST ASCE 7-16 WIND LOADS IN ACCORDANCE WITH FRC R301.2.2.1 <br />TABLE 4: NAIL SIZE LEGEND TABLE 5: FASTENERS IN <br />NOTES 1, 2, 3, a-11 DIAMETER LENGTH PRESSURE TREATED LUMBER <br />8d COMMON <br />0.131" <br />2-Y2" <br />RSRS-01 <br />0.113" <br />2 3/" <br />RSRS-03 <br />0.131" <br />2-Y2" <br />10d <br />0.131" <br />3" <br />10d COMMON <br />0.148" <br />3" <br />12d COMMON <br />0.148" <br />3-Y4" <br />16d SINKER <br />0.148" <br />3-Y+" <br />16d COMMON <br />0.162" _773-Yz" <br />NOTES: <br />1. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED. <br />2. COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS <br />SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM <br />F1667. NOMINAL DIAMETER SIZES APPLY TO FASTENERS <br />BEFORE APPLICATION OF PROTECTIVE COATING. <br />3. WHEN A BORED HOLE IS REQUIRED TO PREVENT SPLITTING OF <br />A WOOD DUE TO FASTENER PENETRATION, THE BORED HOLE <br />SHALL NOT EXCEED 75% OF THE NAIL OR SPIKE DIAMETER. <br />4. THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS <br />SPECIFIED FOR THIS PROJECT ARE AS LISTED IN TABLE 4. <br />PRESERVATIVE <br />FASTENER TYPE <br />ACZA <br />STANDARD CARBON STEEL <br />SODIUM BORATE (NOTE 1) <br />STAINLESS CONNECTORS AND <br />FASTENERS REQUIRED. <br />CONNECTORS MUST HAVE <br />ALL OTHER PT <br />Z-MAX, G120 OR TRIPLE ZINC <br />(INCLUDING ACQ & MCQ) <br />COATED FINISH. <br />ALL FASTENERS MUST BE HOT <br />DIPPED GALVANIZED. <br />NOTES: <br />1. SILL PLATES W/ SODIUM BORATE TREATMENTS BEARING ON <br />CONCRETE OVER VAPOR BARRIER ARE NOT DIRECTLY <br />EXPOSED TO EARTH OR WEATHER AND HAVE BEEN PROVEN <br />TO BE NON -CORROSIVE TO CARBON STEEL FASTENERS. <br />CONCRETE AND FOUNDATION NOTES <br />1. CONCRETE COMPRESSIVE STRENGTH FOR FOOTINGS= 2,500 PSI AT 28 DAYS (UNO). <br />2. CONCRETE COMPRESSIVE STRENGTH FOR SLAB = 2,500 PSI AT 28 DAYS (UNO). <br />3. ALL REINFORCING STEEL #3 AND BIGGER SHALL BE ASTM A615 GRADE 40 DEFORMED BARS (UNO). <br />4. ALL REINFORCING STEEL SHALL HAVE 90 DEGREE BEND AT CORNERS WITH A 24" LAP. 24" LONG #4 BAR IS RECOMMENDED TO BE <br />INSTALLED AT ALL REENTRANT CORNERS. <br />5. FIBERMESH IS AN ACCEPTABLE ALTERNATIVE AND SHALL NOT REQUIRE WWF. FIBER LENGTHS SHALL BE'/2" TO 2" IN LENGTH. <br />DOSAGE AMOUNTS SHALL RANGE FROM 0.75 TO 1.5 POUNDS PER CUBIC YARD IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WHEN REQUESTED BY THE BUILDING OFFICIAL. <br />6. MASONRY STEMWALL AND MONOLITHIC FOOTING ARE INTERCHANGEABLE. <br />7. EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 PSF IN <br />ACCORDANCE WITH TABLE R401A.1, AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. <br />COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY. IT IS THE OWNER'S OR <br />CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS. <br />8. CONCRETE FLOOR SLABS ON GRADE SHALL BE INSTALLED OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH <br />JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL WITH CODE APPROVED PROVISIONS FOR <br />PREVENTION OF SUBTERRANEAN TERMITES. <br />9. STEMWALLS OVER 4 COURSES TALL REQUIRE SPECIAL ATTENTION TO BRACING DURING CONSTRUCTION. CONTACT ENGINEER <br />OF RECORD IF THIS CONDITION EXISTS. <br />10. TO CONTROL CRACKING, CUT 1" SAWCUTS IN THE SLAB IN A 15'x15' GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT. <br />CONTACT FOR FOR ALTERNATIVE METHODS. CONTROL JOINTS ARE NOT REQUIRED WHEN WWF OR FIBERMESH ARE INCLUDED <br />WITH CONCRETE WORK. <br />11. DO NOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. DO NOT DETERMINE FOOTING LOCATION <br />FROM ARCHITECTURAL PLANS OR FRAMING PLAN. IF FOOTING SIZE OR LOCATION IS NOT DETERMINATE FROM USE OF <br />FOUNDATION PLAN ALONE, CONTACT THE ENGINEER OF RECORD. <br />PRE-ENGINEERED TRUSSES & I -JOISTS <br />1. ROOF TRUSS TOP CHORDS SHALL HAVE A MINIMUM SPECIFIC GRAVITY OF 0.49 (SYP SPECIES OR BETTER). <br />2. ROOF OR FLOOR TRUSSES FABRICATED TO ACHIEVE THE ROOF PLANES DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE <br />DESIGNED UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. ENGINEERING SHOP DRAWINGS <br />SHALL BE PREPARED IN ACCORDANCE WITH ANSI/TPI AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO <br />FABRICATION. DESIGN CRITERIA IS LOCATED ON SHEET ST-1 OF THE PLAN SET. TEMPORARY BRACING SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE LEFT IN PLACE AFTER CONSTRUCTION IS COMPLETE. <br />3. TRUSSES OR I -JOISTS SHALL BE DESIGNED TO MATCH THE ORIENTATION, SPAN DIRECTION, SPACING, BEARING LOCATION AND <br />NAMING CONVENTION OF THE LAYOUT SHOWN HERE. <br />4. THE TRUSS ENGINEER SHALL PROVIDE ALL TRUSS TO TRUSS CONNECTION DESIGN AND SPECIFICATIONS AND SUBMIT THEM <br />UNDER SIGN AND SEAL WITH THE TRUSS SHOP DRAWINGS. <br />5. TRUSS UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND TAKEN INTO CONSIDERATION DURING THE DESIGN <br />OF THE UPLIFT RESTRAINT SYSTEM FOR THIS STRUCTURE. AS SUCH, THE REPORTED UPLIFTS ON THE TRUSS SHOP DRAWINGS <br />MAY BE DISREGARDED. <br />6. I -JOISTS FABRICATED TO ACHIEVE THE FLOOR PLANS DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED AND <br />SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SEE DESIGN CRITERIA, <br />THIS SHEET. <br />USP & SIMPSON CONNECTORS IN CORRESPONDING ROWS BELOW ARE EQUAL <br />ALTERNATIVES AND MAY BE CONSIDERED INTERCHANGEABLE <br />SIMPSON <br />SIMPSON FASTENERS <br />MITEK <br />USP FASTENERS <br />SIMPSON <br />SIMPSON <br />FASTENERS <br />MITEK <br />USP FASTENERS <br />(8)% X 1 %" SDS SCREWS <br />(8)'/; x 1'/:" WS15-GC <br />DTT2Z <br />IN STUD Y2" 0 X 4 %" <br />WOOD SCREWS IN STUD <br />(9) 10d COMMON <br />(9) 10d <br />(NOTE 2) <br />EMBED EPDXY OR <br />DTB-TZ <br />% 0 x 4%," EMBED EPDXY <br />CS18 <br />EACH END <br />CS20 <br />COMMON <br />SCREW ANCHOR <br />OR SCREW ANCHOR <br />EACH END <br />(18)0.162"x2 WIN <br />(18)0.162"x2 Y2"IN <br />HTT4 <br />STUD/BEAM/TRUSS <br />HTT45 <br />STUD/BEAM/TRUSS <br />MTS12 <br />(7) 10d x 1 Y2" <br />MTW12 <br />(7) 10d x 1 1/2"(NOTE <br />2) <br />§8 0 x 6" EMBED ANCHOR <br />§8 0 x 6" EMBED ANCHOR <br />EACH END <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />(26) 0.162" x 2 'Y2" IN <br />(26) 0.162" x 2 'Y2" IN <br />HTT5 <br />STUD/BEAM/TRUSS <br />STUD/BEAM/TRUSS <br />(9) 10d COMMON <br />(9) 10d COMMON <br />(NOTE 2) <br />48" 0 x 6" EMBED ANCHOR <br />HTT45 <br />58" 0 x 6" EMBED ANCHOR <br />MSTA24 <br />EACH END <br />MSTA24 <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />(20)%" x 3" SDS SCREWS <br />(24) 3" WS IN STUD <br />HDQ8-SDS3 <br />IN STUD GROUP <br />PHD8 <br />GROUP 7 " 0 x 12" EMBED <br />e <br />MSTA36 <br />(13) 10d COMMON <br />MSTA36 <br />(13) 10d COMMON <br />7/8, O x 12" EMBED <br />ANCHOR IN CONCRETE <br />EACH END <br />EACH END <br />ANCHOR IN CONCRETE <br />(7) 10d x 1 '/2" IN TRUSS <br />(7) 10d x 1 '/2' IN TRUSS <br />(7) 10d COMMON IN <br />(7) 10d COMMON IN <br />META12 <br />4" WET EMBED IN <br />HTA16-18 <br />4" WET EMBED IN <br />MSTAM36 <br />WOOD FRAMING <br />MSTAM36 <br />WOOD FRAMING <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />(4) 'W x 2 %" TITEN <br />(5) 'W x 2 %" TAPCON IN <br />SCREWS IN MASONRY <br />MASONRY <br />(8) 10d x 1 '/2" IN TRUSS <br />(9) 10d x 1 %" IN TRUSS <br />(11) 10d x 1 ''Y2" IN <br />(11) 10d x 1 '/2" IN <br />META20 <br />4" WET EMBED IN <br />HTA20-18 <br />4" WET EMBED IN <br />HTS20 <br />TRUSS/RAFTER <br />HTW20 <br />TRUSS/RAFTER <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />(11) 10d x 1 '/2" IN <br />(11) 10d x 1 ''Y2" IN <br />STUD <br />STUD <br />(12) 10d x 1 %" IN <br />(8) 10d x 1'/2" IN <br />ABU44 <br />12 16d COMMON NAIL S <br />( ) <br />PAU44 <br />12 16d COMMON NAILS <br />( ) O <br />HTSM20 <br />TRUSS/RAFTER /RAFTER <br />S <br />HTWM20 <br />/R TE <br />TRUSS AF R <br />(NOTE 6) <br />48' 0 x 7" EMBED EPDXY <br />§8, f1} x 7" EMBED EPDXY <br />(12) 10d x 1 ''/2" IN <br />(4) %' x 3" WEDGE BOLT <br />STUD <br />OR EQUIVALENT IN STUD <br />(12) 16d COMMON NAILS <br />(12) 16d COMMON NAILS <br />(5) 8d x 1'/2" IN <br />(5) 8d x 1'/2" IN <br />ABU66 <br />%" O x 7' EMBED EPDXY <br />PAU66 <br />4 " 0 x 7" EMBED EPDXY <br />H2.5T/ <br />TRUSS <br />RT7/ <br />TRUSS <br />(NOTE 6) <br />(12" EMBED AT GARAGE <br />(12" EMBED AT GARAGE <br />HA8 <br />(5) 8d x 1 Y2" IN <br />RT7AT <br />(5) 8d x 1 Y2" IN <br />DOOR RETURNS) <br />DOOR RETURNS) <br />TOP PLATE <br />TOP PLATE <br />HU48, <br />(14) 16d COMMON IN <br />HD48, <br />(14) 16d COMMON IN <br />(5) 10d x 1 %" IN <br />(5) 10d x 1 Y2" IN <br />HUC48, <br />HEADER <br />HD481F, <br />HEADER <br />H8 <br />TRUSS <br />RT8A <br />TRUSS <br />HU28-2, <br />HUC28-2 <br />(6) 10d COMMON IN BEAM <br />HD28-2, <br />HD28-21F <br />(6) 10d COMMON IN BEAM <br />(5) 10d x 1 Y2" IN <br />TOP PLATE <br />(5) 10d x 1 Y2" IN <br />TOP PLATE <br />HU410, <br />(18) 16d COMMON IN <br />HD410, <br />(18) 16d COMMON IN <br />(16) 10d COMMON TO <br />HUC410, <br />HEADER <br />HD4101F, <br />HEADER <br />TRUSS/RAFTER <br />TRUSS/RAFTER <br />HU210-2, <br />(10) 10d COMMON IN <br />HD210-2, <br />(10) 10d COMMON IN <br />LGT2 <br />(7) %' x 2 %' TITEN <br />LUGT2 <br />(5) O" x 3" WEDGE BOLT <br />HUC210-2 <br />BEAM <br />HD210-21F <br />BEAM <br />SCREWS IN MASONRY <br />OR EQUIVALENT <br />HUC212-2 <br />(22) 16d COMMON IN <br />HEADER <br />HD212-21F <br />(22) 16d COMMON IN <br />HEADER <br />(26) 16d SINKER <br />(28) 16d SINKER IN WALL <br />10 10d COMMON IN BEAM <br />10 10d COMMON IN BEAM <br />LGT3 <br />IN WALL FRAMING <br />(12) SDS %" x 2 W <br />LUGT3 <br />FRAMING <br />(12) WS25 %" x 2'/" <br />+ + <br />(4)%" x 1 /z' SDS SCREW <br />4 '/;' x 1Yi' WS15 SCREWS <br />() <br />IN TRUSS <br />IN TRUSS <br />IN TRUSS/RAFTER <br />IN TRUSS/ RAFTER <br />HGA10KT <br />(4)%" x 3" SDS SCREWS <br />HGA10 <br />(4) %" x 3" WS3 SCREWS <br />IN TOP PLATE <br />IN TOP PLATE <br />SDWC14500, <br />SDWC15600 <br />NO <br />USP EQUIVALENT <br />(4) SDS %" x 1 %" SCREWS <br />(4) %' x 1Y2' WS15 SCREWS <br />HGAMIOKT <br />IN TRUSS/RAFTER <br />'W <br />HGAM10KT <br />IN TRUSS/ RAFTER <br />(4) /. x 1 /, WEDGE BOLT <br />(4) x 2'/," TITEN SCREWS <br />IN MASONRY <br />OR EQUIVALENT IN <br />MASONRY <br />NOTES: <br />1. REFER TO FRAMING NOTES THIS SHEET FOR ACRYLIC -TIE INSTALLATION SPECIFICATIONS. <br />2. PRODUCTS SELECTED USING SIMPSON 2019-2020 CATALOG. PRODUCTS MAY BE SUBSTITUTED WITH EQUAL OR BETTER APPROVED ALTERNATES. <br />3. REFER TO SIMPSON CATALOG FOR ADDITIONAL INSTALLATION INSTRUCTIONS. <br />4. IF CONNECTOR IS NOT LISTED ABOVE, CONTACT FOR FOR SPECIFIC FASTENING REQUIREMENTS. <br />5. POSITIVE PLACEMENT GUN NAILS, 2 %" LONG, WITH EQUIVALENT DIAMETER TO COMMON NAILS SPECIFIED ABOVE MAY BE USED FOR <br />ABU POST BASE ANCHORS, CS16, AND MSTA FLAT STRAPS. <br />6. MASONRY APPLICATION REQUIRE EQUIVALENT NUMBER OF TITEN ANCHORS IN LIEU OF 16d NAILS TO HDR CONNECTION. CMU REQUIRES <br />/;' 0 x 2 %" TITENS ILO 16d. CONCRETE REQUIRES EQUIVALENT NUMBER OF %" 0 x 1 -1/4" TITENS ILO 16d. <br />MASONRY NOTES <br />1. ALL MASONRY UNITS SHALL HAVE Pm = 1,500 PSI AND SHALL ERECTED IN RUNNING BOND WITH TYPE M OR S MORTAR OVER FULL <br />BED. <br />2. SHOULD LIMITED AREAS OF STACK BOND MASONRY EXIST, EVERY OTHER COURSE SHALL BE EQUIPPED w/ 9 GAUGE LADDER <br />TYPE HORIZONTAL JOINT REINFORCEMENT <br />3. ALL GROUT TO MIXED PER ASTM C476 STANDARDS. Pc = 3,000 PSI. <br />4. VERTICAL WALL REINFORCING TO BE ASTM A615 GRADE 60 REBAR. <br />5. LAPS BETWEEN VERTICAL REINFORCING AND DOWELS TO BE 30". <br />6. VERTICAL REINFORCING TO HAVE 10" STANDARD HOOK INTO BOND BEAM. DOWEL TO HAVE 10" STANDARD HOOK INTO FOOTING <br />7. PRE -CAST MASONRY LINTELS: SEE "TYPICAL PRE -CAST LINTEL OPTIONS" DETAIL ON STRUCTURAL DETAIL SHEET. <br />8. PROVIDE MOISTURE BARRIER FOR ALL UNTREATED LUMBER IN CONTACT WITH MASONRY OR CONCRETE. <br />LEGEND <br />OR <br />LINO <br />FOR <br />EW <br />OSB <br />WSP <br />SYP <br />SPF <br />CONT <br />O.C. <br />LSL <br />LVL <br />PSL <br />SYS 42 <br />2 <br />2 STUDS <br />U) w <br />2 <br />ANCHOR <br />� � <br />"OR" SHALL MEAN THAT EITHER OPTION PROVIDED IS AN EQUAL <br />ALTERNATIVE FOR THE APPLICATION SHOWN <br />UNLESS NOTED OTHERWISE ON PLAN OR DETAIL <br />ENGINEER OF RECORD <br />EACH WAY <br />ORIENTED STRAND BOARD <br />WOOD STRUCTURAL PANEL <br />SOUTHERN YELLOW PINE <br />SPRUCE -PINE -FUR <br />CONTINUOUS <br />ON CENTER <br />1.55E TIMBERSTRAND LSL ENGINEERED LUMBER, 1 W WIDE, UNO. <br />(3 '%" WIDE LSL BEAMS ARE EQUIVALENT TO 2-PLY 1 W BEAM) <br />2.0E MICROLLAM LVL ENGINEERED LUMBER, 1 3/;' WIDE <br />2.0E PARRALLAM PSL ENGINEERED LUMBER, 3 Y2" WIDE, LINO. <br />PROPERLY RATED OPEN WEB HEADER <br />INTERIOR ROOF LOAD BEARING WALL, SPECIFICATIONS <br />OUTLINED ON TYPICAL WALL SECTIONS, DETAIL SHEETS <br />INTERIOR BEARING WALL WITH NO UPLIFT. NO UPLIFT ANCHORS REQUIRED. MINIMUM <br />BOTTOM PLATE ANCHORAGE IS 'Y2" ANCHOR @ 8'-0" O.C. (UNO ON FRAMING PLAN OR <br />SW SPECIFICATIONS) <br />STRUCTURAL WOOD BEAM <br />STUD COLUMN KEYNOTE <br />NUMBER OF SDWC15600 CONNECTING TOP PLATE TO STUDS. <br />NUMBER OF STUDS BELOW BEAM/GIRDER TRUSS. STUDS <br />TO MATCH WALL FRAMING SIZE AND GRADE. LINO. <br />ADDITIONAL CLARITY FOR THE LOCATION OF THE STUD COLUMN <br />BOTTOM OF STUD COLUMN CONNECTION <br />1ST LEVEL STUD COLUMN: HOLDDOWN REQUIRED AT BASE OF COLUMN <br />2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL <br />COLUMN TO 1ST LEVEL STUDS/HEADER/BEAM. <br />"ANCHOR" REQUIRES BOTTOM PLATE ANCHOR WITHIN 3" OF STUD COLUMN <br />NUMBER OF SDWC15450 CONNECTING STUDS TO BOTTOM PLATE <br />HEADER STRAPPING KEYNOTE <br />NUMBER OF STRAPS CONNECTING HEADER TO JACK STUD <br />TYPE OF STRAP CONNECTING HEADER TO JACK STUD <br />KING/JACK GROUP BOTTOM CONNECTION <br />1ST LEVEL STUD GROUP: HOLDDOWN REQUIRED AT BASE OF STUD GROUP <br />2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL STUD <br />GROUP TO 1ST LEVEL STUDS/HEADER/BEAM. <br />NUMBER OF HOLDDOWNS/STRAPS AT BASE OF KING/JACK GROUP <br />NON -BEARING HEADER FRAMING KEYNOTE <br />NO HDR -# NUMBER OF KING STUDS EACH SIDE OF OPENING <br />HEADER MAY BE FRAMED AS NON BEARING HEADER DUE TO LIGHTLY <br />LOADED CONDITIONS ABOVE <br />#2 SYP HEADER FRAMING KEYNOTE <br />(2) 2x10 - 1 / 2 NUMBER OF KING STUDS EACH SIDE OF OPENING <br />NUMBER OF JACK STUDS EACH SIDE OF OPENING <br />DEPTH OF LOAD -BEARING #2 SYP HEADER <br />NUMBER OF PLIES IN HEADER <br />ENGINEERED LUMBER HEADER FRAMING KEYNOTE <br />NUMBER OF KING STUDS EACH SIDE OF OPENING <br />NUMBER OF JACK STUDS EACH SIDE OF OPENING <br />HEADER MATERIAL (LSL, LVL, PSL, OR SYS42) <br />DEPTH OF LOAD -BEARING EWP HEADER <br />NUMBER OF PLIES IN HEADER (1 %" WIDE UNO) <br />HEADER FRAMING <br />1. ALL HEADER JACK AND KING STU DS SHALL BE FASTENED TO EACH OTHER WITH (2) ROWS 10d @ 8" O.C. <br />STAGGERED. <br />2. NON BEARING HEADERS: DUE TO LIGHTLY LOADED CONDITIONS, 49" OR LESS CLEAR -OPENINGS IN AN <br />EXTERIOR WALL DO NOT REQUIRE LOAD BEARING HEADER, SEE PLAN. <br />3. FASTEN ALL MULTI -PLY HEADERS TOGETHER WITH (2) ROWS 10d @ 8" O.C., STAGGERED ALONG EACH EDGE. <br />4. FASTEN ALL HEADERS TO KING STUDS WITH (3)8d TOE NAILS . <br />5. IF HEADER NOT SPECIFIED, CONTACT ENGINEER OF RECORD. <br />6. LINO ON PLAN, MIN (1) SDWC15600 TOP PLT TO KING STUD AND (1) SDWC15450 KING STUD TO BOTTOM PLATE <br />CONNECTION REQUIRED EACH SIDE OF OPENING (NO CONNECTION REQUIRED FOR OPENINGS AT FIRST <br />FLOOR HEADER WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE. <br />7. TOP PLATE TO HEADER CONNECTION PER ONE OF THE FOLLOWING (NO CONNECTION REQUIRED FOR <br />OPENINGS 39" OR LESS, OR AT FIRST FLOOR HEADERS WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE: <br />• SDWC15600 @ MAX 32" O.C. AS SHOWN, "ALTERNATE SECTION (HEADERS),ST-5 <br />•SPHw/(12)10dx1-Y2"@16"O.C. OR <br />• DSP w/ (14) 10d x 1- Y2" @ 16" O.C. OR <br />• FASTEN TRUSS DIRECTLY TO HEADER w/ MTS OR HTS w/ (14) 10d x 1 %" (OR EQUAL APPROVED BY EOR). <br />8. CRIPPLE BLOCKS BELOW LOAD -BEARING HEADERS MAY BE FRAMED AT 24" O.C. <br />FRAMING NOTES <br />1. SIMPSON ACRYLIC -TIE ADHESIVE OR EQUAL SHALL BE USED IN ALL DRILLED AND EPDXIED ANCHOR APPLICATIONS. <br />ANCHOR BOLT, THREADED ROD, OR DOWELED REINFORCING STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN <br />A HOLE AS SPECIFIED BY MANF (TYPICALLY 1/16" TO 1/8" GREATER THAN SPECIFIED ANCHOR DIAMETER). <br />ADHESIVE/EPDXY MUST FILL THE HOLE IN THE CONCRETE AND WOOD BOTTOM PLATE. MANUFACTURER'S <br />SPECIFICATIONS MUST BE FOLLOWED FOR PROPER INSTALLATION. <br />2. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY, UNO. ALL WATERPROOFING AND FIRE SAFETY <br />SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHER. <br />3. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN <br />TABLE 2304.10.1 <br />4. BEAMS IDENTIFIED BY NUMBER ON PLAN ARE TO BE PROVIDED BY TRUSS MANUFACTURER OR LUMBER SUPPLIER. <br />5. FASTEN ALL MULTI -PLY STUD COLUMNS AND CORNERS TOGETHER WITH (2) ROWS 10d @ 8-'O.C. STAGGERED. <br />UPPER LEVEL MULTI -PLY STUD GROUPS BELOW ALL GIRDER LOCATIONS TO BE CONTINUOUS THROUGH FLOOR <br />SYSTEM TO FOUNDATION. (NOT REQUIRED BELOW HEADER JACK/KING STUD GROUPS) <br />O <br />O <br />N <br />N <br />DD <br />O <br />CA <br />N <br />N <br />c'M <br />.J <br />LL <br />w <br />J <br />J <br />z <br />O <br />CO <br />Y <br />U <br />¢ <br />O <br />O <br />T_ <br />W <br />H <br />W <br />J <br />m <br />w <br />Q <br />Z) <br />0 <br />(n <br />U <br />z <br />W <br />w <br />Of <br />O <br />O <br />0) <br />i <br />ti <br />d' <br />LO <br />z <br />07 <br />U) <br />w <br />W <br />m <br />W <br />W <br />z <br />z <br />w <br />0 <br />LL <br />_O <br />H <br />O <br />U <br />O <br />J <br />LL <br />¢ <br />U <br />z <br />C� <br />0 <br />O <br />2 <br />U <br />W <br />X <br />W <br />X <br />6. FASTEN ALL STUDS TO BOTTOM AND TOP PLATES WITH (4)8d TOE NAILS OR (2)16d COMMON END NAILS. m <br />7. FASTEN ALL TRUSSES AND RAFTERS TO TOP PLATES WITH (3)8d TOE NAILS. <br />8. ALL MULTI -PLY TRUSS GIRDERS AND BEAMS TO HAVE SOLID STUD GROUP BELOW MATCHING GIRDER OR BEAM ❑ <br />THICKNESS AND MATCHING WALL STUD SPECIFICATIONS AS NOTED ON STRUCTURAL PLAN, LINO. <br />L11 <br />9. EXTERIOR WALL DESIGN ASSUMES CONTINUOUSLY SHEATHED WITH OSB OR PLYWOOD z <br />O <br />W <br />O <br />H <br />LL <br />} <br />C� <br />O <br />J <br />z <br />U <br />W <br />H <br />X <br />w <br />11 <br />U <br />Q <br />O <br />APEX0 <br />U <br />N <br />tv <br />tds -66 <br />true design studios N <br />9000 REGENCY SQUARE BLVD. <br />SUITE 100, JACKSONVILLE, FL 32211 <br />I <br />7N <br />7 <br />This item has been electronically <br />signed and sealed by Justin M Lanier, <br />PE on the date and/or time stamp <br />shown using a digital signature. <br />Printed copies of this document are <br />>011�of considered signed and sealed <br />nd the signature must be verified <br />by a 3rd Party Certificate Authority <br /><n any electronic copy v J <br />it Q LLl <br />J zUj <br />W <br />LLJ O U) <br />0 F- 2 <br />er <br />O <br />m <br />W <br />a <br />¢_ <br />❑ <br />J <br />W <br />W <br />x <br />x <br />LL <br />a <br />z <br />O <br />0 <br />LL1 <br />z_ <br />W <br />12- <br />LL <br />W <br />Abbott Park -' <br />U <br />(n <br />LOT 028-02 0 <br />- - - - - Q <br />z <br />(a <br />PROJECT NO: ILL! <br />2021.009237 ❑ <br />LL <br />- - - - -- - O <br />DRAWN: <br />JAR 8 <br />_ O <br />CHKD: - LO <br />MJP <br />W <br />J <br />U <br />``,�t►ttttt�i���� (n <br />EN <br />No 85166 <br />* : DocuSigned by: •� <br />O••• IT $� 1[7ADEf:4�31t�� U� <br />OP�N�• <br />•O R , . ; z <br />�f,N A <br />S,IC i � <br />08-03-2021 <br />w <br />REVISIONS: <br />No. Description Date ~' <br />w <br />U <br />--- -- U) <br />- --� z <br />O <br />ST=1 <br />CMUIMETAL CONNECTOR ENGINEERING <br />