Laserfiche WebLink
0 <br />n <br />OWNER'S BATHROOM <br />SCALE: 3/8" =V-0" <br />MIRROR <br />\\ TOWEL BAR <br />a o <br />60 <br />N <br />�; <br />o <br />I <br />BATHROOM 2 <br />SCALE: 3/8" = 1'-0" <br />STAIR DATA: <br />18 RISERS @ 7.153" <br />17 TREADS @ 10" <br />TOTAL RISE = 10'-8 3/4" <br />TOTAL RUN=14'-2" <br />42" KNEE WALL <br />WITH 1x8 CAP & <br />CASING (AT 2nd <br />FLOOR ONLY) <br />\ <br />---------------- \�� -- <br />18 \ <br />17 \ <br />15 <br />14 <br />13 <br />12 <br />11 <br />10 <br />9 <br />8 <br />7 <br />6 <br />5 <br />2x STRINGERS 4 <br />CV <br />ih <br />M. <br />FILLED CELL LEGEND <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 } X 25 J <br />S.H. <br />13 <br />20 X 38 J <br />118,21 X 3711 <br />S.H. <br />14 <br />20X501 <br />18-X50 <br />S.H. <br />15 <br />20X63 <br />18JX624 <br />S.H. <br />16 <br />20 X 72 <br />18 J X 71 J <br />S.H. <br />1H2 <br />271/4X26 <br />26X254 <br />S.H. <br />iH3 <br />271/4X38i <br />26x371 <br />S.H. <br />1 H4 <br />27 J X 50 1 <br />26 x 50 <br />S.H. <br />1H5 <br />274X63 <br />26X621/2 <br />S.H. <br />1H6 <br />27JX72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 J <br />36 4 X 50 <br />S.H. <br />25 <br />37 X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37 X 72 <br />361 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 i <br />S.H. <br />33 <br />54 X 38 J <br />52 4 X 37 J <br />S.H. <br />34 <br />54 X 501 <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 4 <br />S.H. <br />36 <br />54 X 72 <br />52 J X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />(2) 2x8 w/ 1/2" <br />FLITCH HEADER <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL, <br />\ <br />CONT. <br />HAND RAIL <br />1 <br />TYP. STAIR SECTION. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 314" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />II$ <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />__-LJ__- <br />DRYWALL <br />1 1/2" MIN. CLEARANCE <br />BLOCKING AS <br />REQUIRED <br />2x4 #2 SYP. P.T. THRUST <br />BLOCK W/(2)-1/4"x 3 112" <br />TAPCONS . 1ND.c.AND HANDRAIL DETAIL <br />3" FROM EA. END. <br />SCALE: 3" =1'-0" <br />1 1/4" TO 2" DIA <br />HANDRAIL NO <br />LESS THAN 34" <br />NOR MORE THAN <br />38" ABV. TREAD <br />NOSING <br />METAL HANDRAIL <br />BRACKET <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding % inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 318 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />VERIFY <br />AC PAD LOCATION OF <br />A/C PAD <br />HB <br />------------------------------- <br />OUTDOOR LIVING <br />4 <br />9'-4" CLG. A.F.F. <br />o <br />io <br />CONCRETE <br />ir7 <br />'-0" 16'-8" <br />" <br />6'-8" 3'-10" 3'-10" 2'-8" <br />yo <br />6068 SGD <br />o' ~ <br />(24S68BFI <br />REF <br />C <br />I <br />� <br />I <br />� <br />8'-3" <br />3'_2" 6'_7" <br />o <br />O <br />DINING N <br />I <br />KITCHEN w <br />T <br />9'-4" FLAT CLG. <br />9'-4" FLAT CLG. z <br />TILE <br />TILE < <br />I <br />00 <br />I <br />SI N K w/ I <br />iio <br />D/W DISPOSAL I <br />iQ <br />F- - - <br />� <br />I <br />I I <br />I I r - - - J <br />L _J <br />FLRG. LINE <br />-------- - <br />2x8 WALL <br />8'-4" <br />6'_0" 3'-8" <br />16" CNTR. AT 42' <br />C' <br />LO <br />d <br />- <br />CP <br />A.F.F. <br />1/2 WALL <br />v <br />in <br />CAPPED <br />F <br />1 <br />UP 2 <br />- <br />II <br />3 <br />00 <br />N <br />i <br />M <br />GREAT ROOM <br />5 <br />6 <br />9'-4" FLAT CLG. <br />CARPET <br />00 <br />14'-0" <br />_ 7 <br />co <br />io <br />io <br />o <br />9 <br />PW01 <br />D1 <br />10 <br />_ GG <br />TYP. <br />S3 <br />11 <br />12 <br />2x6 WALL <br />L <br />7'-0" 2'-8" 4'-4" <br />o <br />LO <br />ao <br />_ _ _ <br />00 <br />CO <br />*NO UPLIFT* <br />_ <br />pW01 <br />FLRG. LINE Q <br />19 <br />S4 <br />oo <br />°�ryVR• <br />z <br />�-�-�-���-p <br />D1 <br />TYP. <br />N <br />N - i 06 H1 <br />_J TILE <br />FOYER N I <br />o <br />9'-4" FLAT CLG. 2868 <br />_ TILE <br />Q <br />00 <br />v <br />00 <br />� <br />; <br />io <br />9'_4�� v <br />"v <br />iv- <br />T.O.M. <br />o <br />7'-4" <br />2'-6" <br />OT <br />M <br />3068 <br />BUILDER T <br />PROVIDE <br />O <br />APPLIANCE <br />PROTECTION <br />o <br />WHEN REQUIRED <br />PER FBC <br />2'-°" 4'-8" 1-CAR <br />ARAG E <br />o <br />io <br />9'-4" F <br />T CLG. <br />CONCRETE <br />ENTRY <br />o <br />9'-4" CLG. A.F.F. o N <br />cq <br />CONCRETE in <br />v <br />0 <br />r- - - - - - - - - - <br />------- <br />in <br />� I <br />vo I <br />I <br />I <br />0o <br />I <br />v I <br />I <br />I <br />rn <br />p j TYP. @ <br />j <br />0 <br />Cl) <br />r ( GARAGE <br />I <br />Aii;I <br />I K <br />I <br />I <br />S4 <br />Oo <br />I <br />(V <br />tV <br />N <br />o...-n nnnnnc <br />nnno <br />®' <br />1ST FLOOR PLAN - UNIT-C 1624 <br />SCALE:;VV=1'-0" <br />2ND FLOOR PLAN - UNIT-C 1624 <br />SCALE: 4"=1'-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE"C" <br />�A <br />+29.7 / -32.2B <br />+29.7 / -39.7 <br />a <br />+28.3 / -30.8 <br />+28.3 / -37.0 <br />�E <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />GC� <br />SEE SN SHEET OH SEE SN SHEET <br />M140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090 <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL <br />BOND BEAM HGT. AT 10'-8" <br />•' AT <br />;■ill■.■w■■■■■■■■■■■ill ill Iuo■■r <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR <br />664 S.F. <br />2ND FLOOR <br />970 S.F. <br />TOTAL <br />1634 S.F. <br />GARAGE <br />246 S.F. <br />LANAI <br />108 S.F. <br />ENTRY <br />98 S.F. <br />TOTAL SQ, FT. <br />2086 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL <br />EXT FRAME 2 x 4 <br />EXT FRAME 2 x 6 <br />CONDITIONED CEILING <br />R-4.1 HIGH PERM <br />R-11/R-13 KRAFT FACED <br />R-19 KRAFT FACED <br />R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />C14 <br />® Q <br />--aW <br />Cn <br />s S cc <br />L <br />Q. <br />c; <br />Cc <br />a <br />CD <br />'`. <br />4u <br />ON <br />4g F ESq` <br />Ff�'r't? <br />d �Ih' 4fr\III�I Ytl���� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />gW �� E <br />s <br />S N <br />v p <br />w 00 <br />(A <br />N O <br />LL <br />Q dco v. <br />CILrn <br />C -J LL LL W <br />a <br />a <br />Z coq <br />='- 9 o <br />CV O <br />W <br />�2°'°' m <br />zco N Z <br />ul <br />Z N OU U u <br />111111 El 11 <br />z N o <br />z <br />z o <br />a <br />(D o <br />LL <br />o <br />V <br />0 LL, $ <br />N 0� N <br />U <br />W J <br />logo - 0 8 <br />_ <br />I <br />U o N <br />¢ <br />N <br />� <br />I� <br />M <br />w <br />ZZZ <br />M <br />i S <br />p <br />LL. <br />o <br />EE <br />w <br />O W <br />0Z <br />QN <br />z® <br />00. <br />V <br />o <br />� rj <br />Nfu <br />L <br />a� <br />O a <br />Qp <br />¢a <br />wW <br />o6 <br />rp <br />= <br />- c <br />z <br />oY <br />�m <br />m`s <br />o <br />oLL <br />>Z <br />Z <br />J <br />z <br />ul <br />N <br />0 <br />go <br />Q � <br />oa <br />LL <br />a <br />NW <br />W <br />v � <br />�� <br />k <br />o <br />w� <br />.- <br />>E <br />MJGO <br />v <br />01< <br />a <br />03 <br />c O <br />0 <br />> (,0 <br />a, <br />E, <br />ca <br />N <br />� <br />r <br />L <br />CT) <br />cNCO <br />M <br />`n <br />: N <br />CM�I <br />1 <br />r <br />�• <br />60 <br />U <br />U) <br />in <br />N <br />CN <br />H <br />0 <br />In <br />L.C� <br />N <br />p <br />O <br />CCU <br />Q MLA-) <br />i V <br />o <br />o <br />Z <br />cc <br />Nr <br />Co <br />a <br />E <br />U ° <br />c <br />JOB <br />NO: 22-08387-08382 <br />SCALE : AS NOTED <br />SHEET NO. <br />4 <br />1 <br />F - <br />