My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38190 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
38190 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:42:18 PM
Creation date
2/19/2025 11:34:21 AM
Metadata
Fields
Template:
Building Plans
Street #
38190
Location
Fallstone Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
4893
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I <br />SPECIAL PURPOSE OUTLET <br />:V11q <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />(� <br />RECESSED LIGHT FIXTURE <br />�J P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />-� <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�B <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />�]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />'7 <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />HANSON <br />{ BOX <br />i { <br />LAV 'T\ <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />OPT. <br />LAV LAV <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -C- (1624) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1625 S.F. <br />4875 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10875 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33935 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9574 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />1 5200 <br />TOTAL: 31878 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />NEMA 1 <br />200 AMP <br />TER�MAN <br />1�0-200 AMP I If /—Serial Cable <br />M <br />Power Co. Feed —� Ll I_ #4 Solid COPPER Ground <br />II <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />C.O. <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />O <br />OUTDOOR LIVING <br />INSTALL LIGHTi� <br />ROUGH -IN <br />FOR OPT. / <�fi,> <br />FAN/LIGHT <br />GPI <br />QD QDGFI <br />I <br />DINING <br />KITCHEN 1 <br />I <br />FI l0 <br />GFI d <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />/i^ROUGH-IN\ <br />FOR OPT. <br />FAN/LIGHT <br />� I <br />I � <br />W4 <br />EI <br />its �rrrrrrit���Y� <br />NTRY <br />GHT AS 0 <br />ER SPECS <br />f1 <br />1 <br />I � <br />u <br />o <br />�m <br />M <br />I <br />I <br />I <br />I <br />rGF_L <br />C.M <br />1 UPSTAIRS E <br />@ 4 4" <br />`� �� <br />W.H. <br />A.F .F. <br />` O <br />`1 <br />1 <br />IGARAGE <br />I` I <br />1 <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />GF1 <br />--------------- <br />I <br />I <br />J <br />I <br />I <br />Ip Z <br />I <br />IQ a. <br />I <br />I� Q <br />I <br />I� U <br />I <br />1IM w <br />I <br />5 u1 <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL - UNIT-C 1624 <br />SCALE: Ya"=V-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED, LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2ND ELECTRICAL - UNIT-C 1624 <br />SCALE: YV=1'-0" <br />4 <br />,co <br />N' <br />do <br />j"i <br />3 <br />U <br />N <br />0 <br />CV <br />0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W d E <br />0 y <br />a <br />I+ N N 6) <br />V ) <br />O `s <br />o <br />N <br />OE" <br />a) <br />0M C1 w- <br /># LL <br />J <br />a u- <br />N <br />LL <br />a <br />r�i.. <br />m c <br />13Z —a <br />0 <br />a Y <br />ca <br />tu = (0 N [fl <br />W (2 <br />of <br />Z N t`~+) Z <br />IL <br />Q <br />Z OU <br />U <br />U) <br />W <br />11 <br />U CD <br />Z N o <br />z o <br />z o <br />N <br />� /�� M <br />Ul V <br />Q) U' s <br />LL <br />+-, <br />fLi W _ <br />U <br />/^ <br />O W o <br />L✓ U) <br />LORig <br />U � <br />W J <br />r~ <br />co <br />w <br />co <br />o <br />J <br />m E <br />z o <br />Q <br />E <br />t— <br />Rcu 0 <br />0 ' <br />QZ <br />Zg <br />�a <br />W J <br />L <br />(� <br />¢ o <br />Z4 <br />U <br />.0 <br />F <br />O¢ <br />Z <br />W <br />C) <br />J <br />i <br />01 r <br />> d. <br />ai <br />c.6 <br />�. <br />O <br />cN <br />nco <br />�+ Y <br />d' <br />o <br />Liz <br />T <br />C m <br />CD <br />0o <br />E � <br />CD <br />N <br />N <br />LO <br />CD <br />CDC37 <br />c <br />N <br />� CD N <br />< <br />LO <br />00 <br />LO <br />r— <br />E <br />O <br />o <br />Z <br />CU <br />Z <br />E N <br />E O <br />M <br />c <br />c <br />a- <br />U J Q p <br />J <br />JOB <br />NO: 22-06603-06596 <br />SCALE : AS NOTED <br />SHEET NO. <br />15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.