Laserfiche WebLink
GENERAL NOTES <br />- 25 <br />- 26 <br />NOTE: <br />1. THIS DETAIL APPLIES TO OPN'G SIZES <br />UP TO 12". <br />2. OMIT REINF. PLATE AT OPN'GS LESS <br />THAN 31/2". <br />SET BOOT IN <br />MANUFACTURER <br />APPROVED SEALANT <br />PREFABRICATED <br />PIPE BOOT COMPATIBLE <br />WITH ROOFING MEMBRANE <br />RIGID ROOF INSULATION TO MATCH EXTING <br />WELD BOOT TO <br />ROOFING <br />LAP SEALANT <br />EXISTING RIGID ROOF <br />INSULTATION <br />0.054' (16 GA.) MTL. <br />REINF. PLATE 12" <br />LARGER OPN'G. ALL <br />AROUND - WELD TO TOP <br />OF EXIST. METAL DECK <br />TYP VENT OR PIPE THROUGH ROOF DETAIL <br />1" = V-0" <br />EQUIPMENT ATTACHMENT TO <br />COMPLY WITH THE FLORIDA <br />BUILDING CODE. RE: DETAIL <br />10/S60-10 IN STRUCTURAL DWGS <br />TREATED 2x4 <br />BLOCKING — <br />METAL CAP FLASHING BY <br />MECHANICAL OR HVAC <br />CONTRACTOR <br />PRE-FAB INSULATED ROOF <br />CURB BY MECHANICAL OR <br />HVAC CONTRACTOR <br />BASE FLASHING WRAP TOP OF <br />CURB <br />SEALANT <br />MEMBRANE ROOFING <br />RIGID ROOF INSULATION <br />EXISTING ROOF DECK <br />1. RE: SHEET A00-01 FOR GENERAL SYMBOLOGY LEGEND AND <br />ARCHITECTURAL -SPECIFIC LEGENDS / ABBREVIATIONS. <br />2. RE: SHEET G00-01 FOR GENERAL ABBREVIATIONS / EQUIPMENT <br />DESIGNATIONS UTILIZED ACROSS ALL DISCIPLINES AND DRAWING <br />NUMBERING SYSTEM LEGEND. <br />3. RE: GENERAL ARRANGEMENT SHEETS (G10 SERIES) FOR <br />MECH/ELEC/PLBG/FP EQUIPMENT DESIGNATIONS. <br />4. RE: ARCHITECTURAL FINISH SHEETS (A15 SERIES) FOR INFORMATION <br />ON ARCHITECTURAL FINISHES. <br />5. GENERAL CONTRACTOR TO COORDINATE ALL ROOF PENETRATIONS <br />WITH OWNER'S ROOFING VENDOR. <br />® SHEET NOTES <br />1 NEW EXHAUST DUCT - SEE MECH DWGS FOR EXACT SIZE AND LOCATION. <br />COORDINATE PENETRATION WITH STRUCTURAL FRAMING BELOW (RE: <br />S60-10 FOR STRUCTURAL ROOF PENETRATIONS) <br />2 PROVIDE MECHANICAL CURB FOR EXHAUST DUCT (RE: DETAIL 2/A14-2R) <br />3 NEW PIPE THROUGH ROOF - SEE MECH DWGS FOR EXACT SIZE AND <br />LOCATION (RE: DETAIL 3/A14-2R FOR PIPE BOOT DETAIL) <br />CONSULTING ARCHITECT/ENGINEER <br />PROJECT TITLE <br />CLARK, RICHARDSON AND BISKUP <br />CONSULTING ENGINEERS, INC. <br />CRB ARCHITECTS -ENGINEERS P.C. <br />1 GLENLAKE PARKWAY <br />SUITE 600 <br />ATLANTA, GA 30328 <br />PHONE: 404-860-1440 <br />FAX: 404-860-1442 <br />ZEPHYRHILLS LINE 12 <br />REV <br />BY <br />DATE <br />DESCRIPTION <br />0 <br />RJP <br />25AUG21 <br />ISSUED FOR BID <br />1 <br />RJP <br />22SEP21 <br />ISSUED FOR PERMIT <br />LICENSEE <br />I <br />P//:'•� <br />i • <br />0 • 10 <br />t <br />RED`. <br />CRB ARCHITECTS -ENGINEERS P.C. LICENSE #09000002537 <br />CRB CONSULTING ENGINEERS, INC LICENSE #F96000003389 <br />INFORMATION CONTAINED HEREIN IS CONSIDERED CONFIDENTIAL. THIS <br />DOCUMENT IS NOT TO BE USED, REPRODUCED, OR DISCLOSED IN WHOLE OR <br />PART WITHOUT THE PRIOR WRITTEN PERMISSION OF BLUETRITON BRANDS, <br />PROJ. NO. <br />217043.00 <br />DESIGNED BY: <br />CFL <br />SCALE: <br />As indicated <br />CHECKED BY: <br />RJP <br />SHEET SIZE: <br />30x42 <br />APPROVED BY: <br />RJP <br />'DRAWING TITLE <br />ARCHITECTURAL <br />ENLARGED ROOF PLAN <br />ENLARGED ROOF PLAN <br />1/16" = l'-0" <br />FRAMED OPENING <br />REFER TO STRUCTURAL <br />MECHANICAL FASTENER BY <br />ROOFING CONTRACTOR <br />TYP MECHANICAL CURB DETAIL <br />Y =1'-0" <br />- _ - -- .: - - — -- - - - - - -- - -- - - -- - - - - <br />I �' _. 1k •. '#7 , .cH;'; <br />"DRAWING NUMBER <br />Al 4-2R <br />