PIPE LINE TAGGING
<br />PIPING SERVICE DESIGNATIONS
<br />PIPING SYMBOLS
<br />PLUMBING FIXTURE TAGGING
<br />GENERAL
<br />PIPE SPEC DESIGNATION 3 DIGIT SEQUENTIAL NUMBER (IF USED)
<br />SERVICE DESIGNATION INSULATION TYPE (IF USED)
<br />NOMINAL DIAMETER
<br />D"-SSSS-XXXX-N N N-YYY
<br />INV. EL. = 10' - 61/8"
<br />BOP =10'-6"
<br />ULINV. EL. =10' - 61/8"
<br />BOP =10'-6"
<br />SlSlope_ DIRECTION OF DOWNWARD SLOPE
<br />PIPING MATERIAL SPEC DESIGNATIONS
<br />DESIGNATION DESCRIPTION
<br />AY01 AL-6XN, TUBING, 25RA MAX. INSIDE POLISH
<br />C131 CAST IRON, HUB & SPIGOT AND NO -HUB, WASTE SYSTEM
<br />C132 CAST IRON, HUB & SPIGOT, WASTE SYSTEM
<br />C133 CAST IRON, NO -HUB, WASTE SYSTEM
<br />CS01 CARBON STEEL, SCHEDULE 40, FORGED STEEL FITTINGS
<br />CS02 CARBON STEEL, SCHEDULE 80, FORGED STEEL FITTINGS
<br />CS03 CARBON STEEL, SCHEDULE 40, MALLEABLE IRON FITTINGS
<br />CSO4 CARBON STEEL, SCHEDULE 80, MALLEABLE IRON FITTINGS
<br />CS05 CARBON STEEL, SCHEDULE 40, CAST IRON FITTINGS
<br />CS06 CARBON STEEL, SCHEDULE 80, CAST IRON FITTINGS
<br />CS07 CARBON STEEL, SCHEDULE 40, MECHANICAL JOINTS
<br />CS08 CARBON STEEL, SCHEDULE 40, PRE -INSULATED, W/ POLYURETHANE
<br />CS11 CARBON STEEL, SCHEDULE 40, PRE -INSULATED, W/ MINERAL WOOL
<br />CU01 COPPER TUBING, TYPE L, GENERAL
<br />CU02 COPPER TUBING, TYPE L, DEHYDRATED, FOR OXYGEN SERVICE
<br />CU03 COPPER TUBING, TYPE ACR, REFRIGERANT
<br />CU04 COPPER TUBING, TYPE L, DEHYDRATED, CLEAN & CAPPED
<br />CU05 COPPER TUBING, TYPE L, PRE -INSULATED, W/ POLYURETHANE
<br />CU06 COPPER TUBING, TYPE K, HARD DRAWN, GENERAL
<br />CU07 COPPER TUBING, TYPE K, SOFT DRAWN, GENERAL
<br />CU09 COPPER TUBING, TYPE L, HIGH TEMPERATURE, GENERAL
<br />CU10 COPPER TUBING, TYPE K, DEHYDRATED, CLEAN & CAPPED
<br />CU11 COPPER TUBING, TYPE L, PROPRESS
<br />DI02 DUCTILE IRON, WATER PRESSURE PIPE
<br />D131 DURIRON, HIGH SILICON, WASTE SYSTEM
<br />FG31 FIBERGLASS REINFORCED PIPE, (FIBERCAST), WASTE SYSTEM
<br />GL01 GLASS LINED CARBON STEEL PIPE
<br />GS01 GALVANIZED STEEL, SCHEDULE 40, VICTAULIC FITTING
<br />HA01 HASTELLOY C-276, SCHEDULE 40, SCHEDULE 10, WELDED
<br />HA02 HASTELLOY C22 TUBING, MECHANICALLY POLISHED INSIDE, ANNEALED OUTSIDE
<br />KL01 PVDF, (KYNAR), LINED CARBON STEEL PIPE
<br />PP02 POLYPROPYLENE PIPE, SCHEDULE 80, SOCKET FUSION WELDED
<br />PP11 POLYPROPYLENE TUBING, BUTT FUSION WELDED
<br />PP12 POLYPROPYLENE TUBING, BEADLESS BUTTWELD
<br />PP31 POLYPROPYLENE PIPE, FIRE RESISTANT, WASTE SYSTEM
<br />PV01 PVC, POLYVINYL CHLORIDE PIPE, SCHEDULE 40
<br />PV02 PVC, POLYVINYL CHLORIDE PIPE, SCHEDULE 80
<br />PV04 CPVC, CHLORINATED POLYVINYL CHLORIDE, SCHEDULE 80, SOCKETWELD JOINTS
<br />PV11 POLYVINYLIDENE FLUORIDE PIPE, SPIGOT BUTT WELD
<br />PV12 POLYVINYLIDENE FLUORIDE PIPE, FUSION BUTT WELD
<br />PV31 PVC, POLYVINYL CHLORIDE PIPE, WASTE SYSTEM
<br />PV33 PVC, OUTSIDE BUILDING WASTE MANAGEMENT
<br />PV34 CPVC, INSIDE BUILDING WASTE MANAGEMENT
<br />SS01 SST TUBING, BPE, 316L, 25 RA MAX. INSIDE POLISH, ANNEALED OUTSIDE
<br />SS02 SST TUBING, BPE, 316L, ELECTROPOLISHED INSIDE, ANNEALED OUTSIDE
<br />SS03 SST TUBING, 3161_, <_ 1" COMPRESSION FITTED
<br />SSO4 SST PIPE, 304L, MILL INSIDE, MILL OUTSIDE
<br />SS06 SST PIPE, 316L, MILL INSIDE, MILL OUTSIDE
<br />SS07 SST ALLOY PIPE, CARPENTER 20 CB-3
<br />SS08 SST TUBING, 304L, <_ 1" COMPRESSION FITTED
<br />SS10 SST TUBING, 316L, 3000 PSIG RATED, COMPRESSION FITTED
<br />SS11 SST TUBING, 304L, CLEANED & CAPPED, NO POLISH INSIDE
<br />SS12 SST TUBING, 316L, CLEANED & CAPPED, NO POLISH INSIDE
<br />SS30 SST PIPE, 316L, WASTE SYSTEM
<br />SS31 SST TUBING, 304L WASTE PIPING
<br />SS32 SST TUBING, 316L PUSH FIT WASTE PIPING
<br />SS33 SST TUBING, 304L PUSH FIT WASTE PIPING
<br />TL01 TEFLON LINED CARBON STEEL
<br />VJ01 SST TUBING, VACUUM JACKETED, BAYONET FITTINGS
<br />VJ02 SST TUBING, VACUUM JACKETED, BUTTWELD FITTINGS
<br />DESIGNATION DESCRIPTION
<br />ACID
<br />ACID
<br />ALC
<br />ALCOHOL
<br />AR
<br />ARGON
<br />AV
<br />ACID VENT
<br />AW
<br />ACID WASTE
<br />AWFI
<br />AMBIENT WATER FOR INJECTION
<br />B
<br />BRINE
<br />BBD
<br />BOILER BLOW DOWN
<br />BFW
<br />BOILER FEED WATER
<br />BV
<br />BIOVENT
<br />BW
<br />BIOLOGICAL WASTE
<br />BWV
<br />BIOLOGICAL WASTE VENT
<br />CAUS
<br />CAUSTIC
<br />CA
<br />COMPRESSED AIR
<br />CCA
<br />CLEAN COMPRESSED AIR
<br />CD
<br />CONDENSATE DRAIN
<br />CGR
<br />CHILLED GLYCOL RETURN
<br />CGS
<br />CHILLED GLYCOL SUPPLY
<br />CHF
<br />CHEMICAL FEED
<br />CHWR
<br />CHILLED WATER RETURN
<br />CHWS
<br />CHILLED WATER SUPPLY
<br />CIPA
<br />CIP ACID
<br />CIPB
<br />CIP BASE
<br />CIPR
<br />CLEAN IN PLACE RETURN
<br />CIPS
<br />CLEAN IN PLACE SUPPLY
<br />CO
<br />CARBON MONOXIDE
<br />CO2
<br />CARBON DIOXIDE
<br />CS
<br />CLEAN STEAM
<br />CWFI
<br />COLD WATER FOR INJECTION
<br />CWR
<br />COOLING WATER RETURN
<br />CWS
<br />COOLING WATER SUPPLY
<br />DCW
<br />DOMESTIC COLD WATER
<br />DHW
<br />DOMESTIC HOT WATER
<br />DHWR
<br />DOMESTIC HOT WATER RETURN
<br />DI
<br />DEIONIZED WATER
<br />EG ETHYLENE GLYCOL
<br />ETOH ETHANOL
<br />FOR
<br />FUEL OIL RETURN
<br />FOS
<br />FUEL OIL SUPPLY
<br />FOV
<br />FUEL OIL VENT
<br />FP
<br />FIRE PROTECTION
<br />FPBS
<br />FIRE PROTECTION BLACK STEEL
<br />FPGS
<br />FIRE PROTECTION GALVANIZED STEEL
<br />FPSS
<br />FIRE PROTECTION STAINLESS STEEL
<br />GLC
<br />GLUCOSE
<br />H2
<br />HYDROGEN
<br />HE
<br />HELIUM
<br />HHWR
<br />HEATING HOT WATER RETURN
<br />HHWS
<br />HEATING HOT WATER SUPPLY
<br />HPC
<br />HIGH PRESSURE PLANT STEAM CONDENSATE
<br />HIPS
<br />HIGH PRESSURE PLANT STEAM
<br />HS
<br />HUMIDIFICATION STEAM
<br />HWFI
<br />HOT WATER FOR INJECTION
<br />IA
<br />INSTRUMENT AIR
<br />ICW
<br />INDUSTRIAL COLD WATER
<br />IHW
<br />INDUSTRIAL HOT WATER
<br />IHWR
<br />INDUSTRIAL HOT WATER RETURN
<br />IPA
<br />ISOPROPYL ALCOHOL
<br />IV
<br />INDUSTRIAL VENT
<br />IW
<br />INDUSTRIAL WASTE
<br />DESIGNATION DESCRIPTION
<br />LCO2
<br />LIQUID CARBON DIOXIDE
<br />LCW
<br />LAB COLD WATER
<br />LHW
<br />LAB HOT WATER
<br />LHWR
<br />LAB HOT WATER RETURN
<br />LN2
<br />LIQUID NITROGEN
<br />LPC
<br />LOW PRESSURE PLANT STEAM CONDENSATE
<br />LPG
<br />LIQUIFIED PETROLEUM GAS
<br />LPS
<br />LOW PRESSURE PLANT STEAM
<br />LW
<br />LAB WASTE
<br />LWV
<br />LAB WASTE VENT
<br />MPC MEDIUM PRESSURE PLANT STEAM CONDENSATE
<br />MPS MEDIUM PRESSURE PLANT STEAM
<br />N2
<br />NITROGEN
<br />NG
<br />NATURAL GAS
<br />N20
<br />NITROUS OXIDE
<br />NPCW
<br />NON -POTABLE COLD WATER
<br />NPHW
<br />NON -POTABLE HOT WATER
<br />02 OXYGEN
<br />OSW OVERFLOW STORM WATER
<br />P
<br />PROCESS
<br />PA
<br />PROCESS AIR
<br />PC
<br />PUMPED CONDENSATE
<br />PCHR
<br />PROCESS CHILLED WATER RETURN
<br />PCHS
<br />PROCESS CHILLED WATER SUPPLY
<br />PTWR
<br />PROCESS TEMPERED WATER RETURN
<br />PTWS
<br />PROCESS TEMPERED WATER SUPPLY
<br />PUR
<br />PURIFIED WATER
<br />PV
<br />PROCESS VENT
<br />PW
<br />PROCESS WASTE
<br />PWV
<br />PROCESS WASTE VENT
<br />RG
<br />REFRIGERANT HOT GAS
<br />RL
<br />REFRIGERANT LIQUID
<br />RO
<br />REVERSE OSMOSIS
<br />IRS
<br />REFRIGERANT SUCTION
<br />RV
<br />RELIEF VENT
<br />SAN
<br />SANITARY WASTE
<br />SFT
<br />SOFT WATER
<br />SV
<br />SANITARY VENT
<br />SW
<br />STORM WATER
<br />TSWR
<br />THERMAL STORAGE WATER RETURN
<br />TSWS
<br />THERMAL STORAGE WATER SUPPLY
<br />TWR
<br />TOWER WATER RETURN
<br />TWS
<br />TOWER WATER SUPPLY
<br />TEWR
<br />TEPID WATER RETURN
<br />TEWS
<br />TEPID WATER SUPPLY
<br />USP
<br />USP PURIFIED WATER
<br />VW
<br />VIRAL WASTE
<br />VWV
<br />VIRAL WASTE VENT
<br />VAC
<br />VACUUM
<br />WFI WATER FOR INJECTION
<br />PIPING TO BE REMOVED FIXTURE CALLOUT
<br />OPTIONAL SIZE (IF USED) TYPE NUMBER - REFER TO FIXTURE
<br />PIPING TO REMAIN SCHEDULE FOR MORE INFORMATION
<br />NEW PIPING
<br />FLANGED CONNECTION/BLIND FLANGE
<br />PIPE CAP
<br />REDUCER
<br />PIPE DROP/PIPE RISE
<br />BOTTOM OUTLET TEE
<br />TOP OUTLET TEE
<br />PLUMBING FIXTURE CALLOUTS
<br />DESIGNATION DESCRIPTION
<br />CO IN -LINE CLEANOUT
<br />DF
<br />DRINKING FOUNTAIN
<br />DSN
<br />DOWNSPOUT NOZZLE
<br />DW
<br />DISH WASHER
<br />ECO
<br />EXTERIOR CLEANOUT
<br />ES
<br />EMERGENCY SHOWERICOMBINATION UNIT
<br />EW
<br />EMERGENCY EYE WASH
<br />EWC
<br />ELECTRIC WATER COOLER
<br />EWH
<br />EXTERIOR WALL HYDRANT
<br />FCO
<br />FLOOR CLEANOUT
<br />FD
<br />FLOOR DRAIN
<br />FS
<br />FLOOR SINK
<br />HB HOSE BIBS
<br />HS HOSE STATION
<br />HSK HAND SINK
<br />IM
<br />ICE MACHINE
<br />IMB
<br />ICE MAKER BOX
<br />IP
<br />INSPECTION PORT
<br />LAV
<br />LAVATORY
<br />LID
<br />LINEAR DRAIN
<br />LSK
<br />LAB SINK
<br />MB JANITOR'S MOP BASIN
<br />ORD OVERFLOW ROOF DRAIN
<br />RD
<br />ROOF DRAIN
<br />RH
<br />ROOF HYDRANT
<br />SB
<br />SHOWER BASIN
<br />SD
<br />SHOWER DRAIN
<br />SH
<br />SHOWER VALVE/SHOWER ENCLOSURE
<br />SK
<br />SINK
<br />SSK
<br />STANDING SERVICE SINK/STANDING MOP SINK
<br />TD
<br />TRENCH DRAIN
<br />TMV
<br />THERMOSTATIC MIXING VALVE
<br />TP
<br />TRAP PRIMER
<br />UR URINAL
<br />WB
<br />WASHER BOX
<br />WC
<br />WATER CLOSET
<br />WCO
<br />WALL CLEANOUT
<br />WF
<br />WASH FOUNTAIN
<br />WSK
<br />WASHROOM SINK/SCULLARY SINK
<br />YCO
<br />YARD CLEANOUT
<br />YH
<br />YARD HYDRANT
<br />COLUMN LINE REFERENCE
<br />1
<br />i
<br />i
<br />BUILDING SECTION REFERENCE
<br />SECTION NUMBER
<br />#
<br />X00-00 SHEET WHERE SECTION
<br />IS DRAWN, SAME DISCIPLINE
<br />WALL SECTION REFERENCE
<br />SECTION NUMBER
<br />XXX WALL SECTION REFERENCE TYPE
<br /># (WHERE APPLICABLE)
<br />X00 00 SHEET WHERE SECTION
<br />IS DRAWN, SAME DISCIPLINE
<br />DETAIL REFERENCE
<br />DETAIL NUMBER
<br /># XXX DETAIL REFERENCE TYPE
<br />(WHERE APPLICABLE)
<br />X0SHEET WHERE DETAIL
<br />IS DRAWN, SAME DISCIPLINE
<br />CALLOUT
<br />DETAIL NUMBER
<br /># XXX— CALLOUT REFERENCE TYPE
<br />(WHERE APPLICABLE)
<br />X00-00
<br />— SHEET WHERE DETAIL
<br />IS DRAWN, SAME DISCIPLINE
<br />— J
<br />EXTERIOR ELEVATION REFERENCE
<br /># ELEVATION NUMBER
<br />X00-00 SHEET WHERE ELEVATION
<br />IS DRAWN, SAME DISCIPLINE
<br />INTERIOR ELEVATION REFERENCE (SINGLE AND MULTIPLE)
<br />ELEVATION NUMBER
<br />XXX # XXX ELEVATION REFERENCE TYPE
<br />(WHERE APPLICABLE)
<br />X00-00
<br />SHEET WHERE ELEVATION IS
<br />DRAWN, SAME DISCIPLINE
<br />REFERENCE TYPES (SECTION 1 DETAIL 1 CALLOUT I ELEVATION)
<br />OPP = OPPOSITE
<br />SYM = SIMILAR
<br />TYP = TYPICAL
<br />SHEET NOTE REFERENCE
<br />/111-0
<br />PATH OF EGRESS
<br />DRAWING REVISION
<br />REVISION NUMBER, SEE
<br />DESCRIPTION IN TITLE
<br />BLOCK SAME SHEET
<br />REVISION AREA
<br />DIMENSIONS
<br />(+/-) DIMENSIONS ARE FOR
<br />REFERENCE ONLY. CONTRACTOR
<br />SHALL FIELD VERIFY AND NOTIFY
<br />ARCHITECT/ENGINEER OF ANY
<br />+/- X X DISCREPANCIES
<br />+/- X' - X" X' - X" SET DIMENSIONS
<br />(NON +/- DIMENSIONS)
<br />ROOM 1 SPACE NAME
<br />ROOM NAME ROOM NAME
<br />101 ROOM NUMBER
<br />150 SF ~ ROOM AREA
<br />NORTH ARROW
<br />INDICATES DIRECTION
<br />OF TRUE NORTH
<br />N INDICATES DIRECTION
<br />OF PROJECT NORTH
<br />LEVEL
<br />LEVEL NAME
<br />0'-0"
<br />MATCH LINE
<br />BREAK LINE
<br />MATCHLINE
<br />RE:X00-00
<br />PLAN ELEVATION MARKER
<br />iHEIGHT ABOVE I BELOW
<br />ESTABLISHED 0.0 ELEVATION
<br />EQUIPMENT TAG
<br />TAG ID
<br />DEMOLITION EXTENT
<br />CONNECT TO EXISTING
<br />�# OPTIONAL NUMBER DESIGNATION
<br />DEMOLITION LINEWORK
<br />SHEET NOTE (DEMO AND NEW WORK) OBJECT TO BE REMOVED
<br />SEE NOTE LEGEND ON SAME SHEET.
<br />CONSULTING ARCHITECT/ENGINEER
<br />I CLARK, RICHARDSON AND BISKUP
<br />CONSULTING ENGINEERS, INC.
<br />CRB ARCHITECTS -ENGINEERS P.C.
<br />1 GLENLAKE PARKWAY
<br />SUITE 600
<br />\ ATLANTA, GA 30328
<br />PHONE: 404-860-1440
<br />FAX: 404-860-1442
<br />PROJECT TITLE
<br />ZEPHYRHILLS LINE 12
<br />REV
<br />BY
<br />DATE
<br />DESCRIPTION
<br />0
<br />GJH
<br />25AUG21
<br />ISSUED FOR BID
<br />1
<br />GJH
<br />22SEP21
<br />ISSUED FOR PERMIT
<br />LICENSEE _ 1 1 ' (jig,
<br />Gordon James Handziuk, PE
<br />State of Florida
<br />Professional Engineer
<br />License No. 91122
<br />This item has been digitally signed and
<br />sealed by Gordon James Handziuk, PE
<br />on the date adjacent to the seal.
<br />Printed copies of this document are not
<br />considered signed and sealed and the
<br />signature must be verified on any
<br />electronic copies.
<br />129 Sep 2021
<br />CRB ARCHITECTS -ENGINEERS P.C. LICENSE #09000002537
<br />CRB CONSULTING ENGINEERS, INC LICENSE #F96000003389
<br />INFORMATION CONTAINED HEREIN IS CONSIDERED CONFIDENTIAL. THIS
<br />DOCUMENT IS NOT TO BE USED, REPRODUCED, OR DISCLOSED IN WHOLE OR
<br />PART WITHOUT THE PRIOR WRITTEN PERMISSION OF BLUETRITON BRANDS.
<br />PROJ. NO.
<br />217043.00
<br />DESIGNED BY:
<br />SB
<br />SCALE:
<br />NOT TO SCALE
<br />CHECKED BY:
<br />GJH
<br />SHEET SIZE:
<br />30x42
<br />APPROVED BY:
<br />GJH
<br />DRAWING TITLE
<br />PLUMBING
<br />LEAD SHEET
<br />�DRAWNG NUMBER
<br />POO-01
<br />
|