PIPE LINE TAGGING <br />PIPING SERVICE DESIGNATIONS <br />PIPING SYMBOLS <br />PLUMBING FIXTURE TAGGING <br />GENERAL <br />PIPE SPEC DESIGNATION 3 DIGIT SEQUENTIAL NUMBER (IF USED) <br />SERVICE DESIGNATION INSULATION TYPE (IF USED) <br />NOMINAL DIAMETER <br />D"-SSSS-XXXX-N N N-YYY <br />INV. EL. = 10' - 61/8" <br />BOP =10'-6" <br />ULINV. EL. =10' - 61/8" <br />BOP =10'-6" <br />SlSlope_ DIRECTION OF DOWNWARD SLOPE <br />PIPING MATERIAL SPEC DESIGNATIONS <br />DESIGNATION DESCRIPTION <br />AY01 AL-6XN, TUBING, 25RA MAX. INSIDE POLISH <br />C131 CAST IRON, HUB & SPIGOT AND NO -HUB, WASTE SYSTEM <br />C132 CAST IRON, HUB & SPIGOT, WASTE SYSTEM <br />C133 CAST IRON, NO -HUB, WASTE SYSTEM <br />CS01 CARBON STEEL, SCHEDULE 40, FORGED STEEL FITTINGS <br />CS02 CARBON STEEL, SCHEDULE 80, FORGED STEEL FITTINGS <br />CS03 CARBON STEEL, SCHEDULE 40, MALLEABLE IRON FITTINGS <br />CSO4 CARBON STEEL, SCHEDULE 80, MALLEABLE IRON FITTINGS <br />CS05 CARBON STEEL, SCHEDULE 40, CAST IRON FITTINGS <br />CS06 CARBON STEEL, SCHEDULE 80, CAST IRON FITTINGS <br />CS07 CARBON STEEL, SCHEDULE 40, MECHANICAL JOINTS <br />CS08 CARBON STEEL, SCHEDULE 40, PRE -INSULATED, W/ POLYURETHANE <br />CS11 CARBON STEEL, SCHEDULE 40, PRE -INSULATED, W/ MINERAL WOOL <br />CU01 COPPER TUBING, TYPE L, GENERAL <br />CU02 COPPER TUBING, TYPE L, DEHYDRATED, FOR OXYGEN SERVICE <br />CU03 COPPER TUBING, TYPE ACR, REFRIGERANT <br />CU04 COPPER TUBING, TYPE L, DEHYDRATED, CLEAN & CAPPED <br />CU05 COPPER TUBING, TYPE L, PRE -INSULATED, W/ POLYURETHANE <br />CU06 COPPER TUBING, TYPE K, HARD DRAWN, GENERAL <br />CU07 COPPER TUBING, TYPE K, SOFT DRAWN, GENERAL <br />CU09 COPPER TUBING, TYPE L, HIGH TEMPERATURE, GENERAL <br />CU10 COPPER TUBING, TYPE K, DEHYDRATED, CLEAN & CAPPED <br />CU11 COPPER TUBING, TYPE L, PROPRESS <br />DI02 DUCTILE IRON, WATER PRESSURE PIPE <br />D131 DURIRON, HIGH SILICON, WASTE SYSTEM <br />FG31 FIBERGLASS REINFORCED PIPE, (FIBERCAST), WASTE SYSTEM <br />GL01 GLASS LINED CARBON STEEL PIPE <br />GS01 GALVANIZED STEEL, SCHEDULE 40, VICTAULIC FITTING <br />HA01 HASTELLOY C-276, SCHEDULE 40, SCHEDULE 10, WELDED <br />HA02 HASTELLOY C22 TUBING, MECHANICALLY POLISHED INSIDE, ANNEALED OUTSIDE <br />KL01 PVDF, (KYNAR), LINED CARBON STEEL PIPE <br />PP02 POLYPROPYLENE PIPE, SCHEDULE 80, SOCKET FUSION WELDED <br />PP11 POLYPROPYLENE TUBING, BUTT FUSION WELDED <br />PP12 POLYPROPYLENE TUBING, BEADLESS BUTTWELD <br />PP31 POLYPROPYLENE PIPE, FIRE RESISTANT, WASTE SYSTEM <br />PV01 PVC, POLYVINYL CHLORIDE PIPE, SCHEDULE 40 <br />PV02 PVC, POLYVINYL CHLORIDE PIPE, SCHEDULE 80 <br />PV04 CPVC, CHLORINATED POLYVINYL CHLORIDE, SCHEDULE 80, SOCKETWELD JOINTS <br />PV11 POLYVINYLIDENE FLUORIDE PIPE, SPIGOT BUTT WELD <br />PV12 POLYVINYLIDENE FLUORIDE PIPE, FUSION BUTT WELD <br />PV31 PVC, POLYVINYL CHLORIDE PIPE, WASTE SYSTEM <br />PV33 PVC, OUTSIDE BUILDING WASTE MANAGEMENT <br />PV34 CPVC, INSIDE BUILDING WASTE MANAGEMENT <br />SS01 SST TUBING, BPE, 316L, 25 RA MAX. INSIDE POLISH, ANNEALED OUTSIDE <br />SS02 SST TUBING, BPE, 316L, ELECTROPOLISHED INSIDE, ANNEALED OUTSIDE <br />SS03 SST TUBING, 3161_, <_ 1" COMPRESSION FITTED <br />SSO4 SST PIPE, 304L, MILL INSIDE, MILL OUTSIDE <br />SS06 SST PIPE, 316L, MILL INSIDE, MILL OUTSIDE <br />SS07 SST ALLOY PIPE, CARPENTER 20 CB-3 <br />SS08 SST TUBING, 304L, <_ 1" COMPRESSION FITTED <br />SS10 SST TUBING, 316L, 3000 PSIG RATED, COMPRESSION FITTED <br />SS11 SST TUBING, 304L, CLEANED & CAPPED, NO POLISH INSIDE <br />SS12 SST TUBING, 316L, CLEANED & CAPPED, NO POLISH INSIDE <br />SS30 SST PIPE, 316L, WASTE SYSTEM <br />SS31 SST TUBING, 304L WASTE PIPING <br />SS32 SST TUBING, 316L PUSH FIT WASTE PIPING <br />SS33 SST TUBING, 304L PUSH FIT WASTE PIPING <br />TL01 TEFLON LINED CARBON STEEL <br />VJ01 SST TUBING, VACUUM JACKETED, BAYONET FITTINGS <br />VJ02 SST TUBING, VACUUM JACKETED, BUTTWELD FITTINGS <br />DESIGNATION DESCRIPTION <br />ACID <br />ACID <br />ALC <br />ALCOHOL <br />AR <br />ARGON <br />AV <br />ACID VENT <br />AW <br />ACID WASTE <br />AWFI <br />AMBIENT WATER FOR INJECTION <br />B <br />BRINE <br />BBD <br />BOILER BLOW DOWN <br />BFW <br />BOILER FEED WATER <br />BV <br />BIOVENT <br />BW <br />BIOLOGICAL WASTE <br />BWV <br />BIOLOGICAL WASTE VENT <br />CAUS <br />CAUSTIC <br />CA <br />COMPRESSED AIR <br />CCA <br />CLEAN COMPRESSED AIR <br />CD <br />CONDENSATE DRAIN <br />CGR <br />CHILLED GLYCOL RETURN <br />CGS <br />CHILLED GLYCOL SUPPLY <br />CHF <br />CHEMICAL FEED <br />CHWR <br />CHILLED WATER RETURN <br />CHWS <br />CHILLED WATER SUPPLY <br />CIPA <br />CIP ACID <br />CIPB <br />CIP BASE <br />CIPR <br />CLEAN IN PLACE RETURN <br />CIPS <br />CLEAN IN PLACE SUPPLY <br />CO <br />CARBON MONOXIDE <br />CO2 <br />CARBON DIOXIDE <br />CS <br />CLEAN STEAM <br />CWFI <br />COLD WATER FOR INJECTION <br />CWR <br />COOLING WATER RETURN <br />CWS <br />COOLING WATER SUPPLY <br />DCW <br />DOMESTIC COLD WATER <br />DHW <br />DOMESTIC HOT WATER <br />DHWR <br />DOMESTIC HOT WATER RETURN <br />DI <br />DEIONIZED WATER <br />EG ETHYLENE GLYCOL <br />ETOH ETHANOL <br />FOR <br />FUEL OIL RETURN <br />FOS <br />FUEL OIL SUPPLY <br />FOV <br />FUEL OIL VENT <br />FP <br />FIRE PROTECTION <br />FPBS <br />FIRE PROTECTION BLACK STEEL <br />FPGS <br />FIRE PROTECTION GALVANIZED STEEL <br />FPSS <br />FIRE PROTECTION STAINLESS STEEL <br />GLC <br />GLUCOSE <br />H2 <br />HYDROGEN <br />HE <br />HELIUM <br />HHWR <br />HEATING HOT WATER RETURN <br />HHWS <br />HEATING HOT WATER SUPPLY <br />HPC <br />HIGH PRESSURE PLANT STEAM CONDENSATE <br />HIPS <br />HIGH PRESSURE PLANT STEAM <br />HS <br />HUMIDIFICATION STEAM <br />HWFI <br />HOT WATER FOR INJECTION <br />IA <br />INSTRUMENT AIR <br />ICW <br />INDUSTRIAL COLD WATER <br />IHW <br />INDUSTRIAL HOT WATER <br />IHWR <br />INDUSTRIAL HOT WATER RETURN <br />IPA <br />ISOPROPYL ALCOHOL <br />IV <br />INDUSTRIAL VENT <br />IW <br />INDUSTRIAL WASTE <br />DESIGNATION DESCRIPTION <br />LCO2 <br />LIQUID CARBON DIOXIDE <br />LCW <br />LAB COLD WATER <br />LHW <br />LAB HOT WATER <br />LHWR <br />LAB HOT WATER RETURN <br />LN2 <br />LIQUID NITROGEN <br />LPC <br />LOW PRESSURE PLANT STEAM CONDENSATE <br />LPG <br />LIQUIFIED PETROLEUM GAS <br />LPS <br />LOW PRESSURE PLANT STEAM <br />LW <br />LAB WASTE <br />LWV <br />LAB WASTE VENT <br />MPC MEDIUM PRESSURE PLANT STEAM CONDENSATE <br />MPS MEDIUM PRESSURE PLANT STEAM <br />N2 <br />NITROGEN <br />NG <br />NATURAL GAS <br />N20 <br />NITROUS OXIDE <br />NPCW <br />NON -POTABLE COLD WATER <br />NPHW <br />NON -POTABLE HOT WATER <br />02 OXYGEN <br />OSW OVERFLOW STORM WATER <br />P <br />PROCESS <br />PA <br />PROCESS AIR <br />PC <br />PUMPED CONDENSATE <br />PCHR <br />PROCESS CHILLED WATER RETURN <br />PCHS <br />PROCESS CHILLED WATER SUPPLY <br />PTWR <br />PROCESS TEMPERED WATER RETURN <br />PTWS <br />PROCESS TEMPERED WATER SUPPLY <br />PUR <br />PURIFIED WATER <br />PV <br />PROCESS VENT <br />PW <br />PROCESS WASTE <br />PWV <br />PROCESS WASTE VENT <br />RG <br />REFRIGERANT HOT GAS <br />RL <br />REFRIGERANT LIQUID <br />RO <br />REVERSE OSMOSIS <br />IRS <br />REFRIGERANT SUCTION <br />RV <br />RELIEF VENT <br />SAN <br />SANITARY WASTE <br />SFT <br />SOFT WATER <br />SV <br />SANITARY VENT <br />SW <br />STORM WATER <br />TSWR <br />THERMAL STORAGE WATER RETURN <br />TSWS <br />THERMAL STORAGE WATER SUPPLY <br />TWR <br />TOWER WATER RETURN <br />TWS <br />TOWER WATER SUPPLY <br />TEWR <br />TEPID WATER RETURN <br />TEWS <br />TEPID WATER SUPPLY <br />USP <br />USP PURIFIED WATER <br />VW <br />VIRAL WASTE <br />VWV <br />VIRAL WASTE VENT <br />VAC <br />VACUUM <br />WFI WATER FOR INJECTION <br />PIPING TO BE REMOVED FIXTURE CALLOUT <br />OPTIONAL SIZE (IF USED) TYPE NUMBER - REFER TO FIXTURE <br />PIPING TO REMAIN SCHEDULE FOR MORE INFORMATION <br />NEW PIPING <br />FLANGED CONNECTION/BLIND FLANGE <br />PIPE CAP <br />REDUCER <br />PIPE DROP/PIPE RISE <br />BOTTOM OUTLET TEE <br />TOP OUTLET TEE <br />PLUMBING FIXTURE CALLOUTS <br />DESIGNATION DESCRIPTION <br />CO IN -LINE CLEANOUT <br />DF <br />DRINKING FOUNTAIN <br />DSN <br />DOWNSPOUT NOZZLE <br />DW <br />DISH WASHER <br />ECO <br />EXTERIOR CLEANOUT <br />ES <br />EMERGENCY SHOWERICOMBINATION UNIT <br />EW <br />EMERGENCY EYE WASH <br />EWC <br />ELECTRIC WATER COOLER <br />EWH <br />EXTERIOR WALL HYDRANT <br />FCO <br />FLOOR CLEANOUT <br />FD <br />FLOOR DRAIN <br />FS <br />FLOOR SINK <br />HB HOSE BIBS <br />HS HOSE STATION <br />HSK HAND SINK <br />IM <br />ICE MACHINE <br />IMB <br />ICE MAKER BOX <br />IP <br />INSPECTION PORT <br />LAV <br />LAVATORY <br />LID <br />LINEAR DRAIN <br />LSK <br />LAB SINK <br />MB JANITOR'S MOP BASIN <br />ORD OVERFLOW ROOF DRAIN <br />RD <br />ROOF DRAIN <br />RH <br />ROOF HYDRANT <br />SB <br />SHOWER BASIN <br />SD <br />SHOWER DRAIN <br />SH <br />SHOWER VALVE/SHOWER ENCLOSURE <br />SK <br />SINK <br />SSK <br />STANDING SERVICE SINK/STANDING MOP SINK <br />TD <br />TRENCH DRAIN <br />TMV <br />THERMOSTATIC MIXING VALVE <br />TP <br />TRAP PRIMER <br />UR URINAL <br />WB <br />WASHER BOX <br />WC <br />WATER CLOSET <br />WCO <br />WALL CLEANOUT <br />WF <br />WASH FOUNTAIN <br />WSK <br />WASHROOM SINK/SCULLARY SINK <br />YCO <br />YARD CLEANOUT <br />YH <br />YARD HYDRANT <br />COLUMN LINE REFERENCE <br />1 <br />i <br />i <br />BUILDING SECTION REFERENCE <br />SECTION NUMBER <br /># <br />X00-00 SHEET WHERE SECTION <br />IS DRAWN, SAME DISCIPLINE <br />WALL SECTION REFERENCE <br />SECTION NUMBER <br />XXX WALL SECTION REFERENCE TYPE <br /># (WHERE APPLICABLE) <br />X00 00 SHEET WHERE SECTION <br />IS DRAWN, SAME DISCIPLINE <br />DETAIL REFERENCE <br />DETAIL NUMBER <br /># XXX DETAIL REFERENCE TYPE <br />(WHERE APPLICABLE) <br />X0SHEET WHERE DETAIL <br />IS DRAWN, SAME DISCIPLINE <br />CALLOUT <br />DETAIL NUMBER <br /># XXX— CALLOUT REFERENCE TYPE <br />(WHERE APPLICABLE) <br />X00-00 <br />— SHEET WHERE DETAIL <br />IS DRAWN, SAME DISCIPLINE <br />— J <br />EXTERIOR ELEVATION REFERENCE <br /># ELEVATION NUMBER <br />X00-00 SHEET WHERE ELEVATION <br />IS DRAWN, SAME DISCIPLINE <br />INTERIOR ELEVATION REFERENCE (SINGLE AND MULTIPLE) <br />ELEVATION NUMBER <br />XXX # XXX ELEVATION REFERENCE TYPE <br />(WHERE APPLICABLE) <br />X00-00 <br />SHEET WHERE ELEVATION IS <br />DRAWN, SAME DISCIPLINE <br />REFERENCE TYPES (SECTION 1 DETAIL 1 CALLOUT I ELEVATION) <br />OPP = OPPOSITE <br />SYM = SIMILAR <br />TYP = TYPICAL <br />SHEET NOTE REFERENCE <br />/111-0 <br />PATH OF EGRESS <br />DRAWING REVISION <br />REVISION NUMBER, SEE <br />DESCRIPTION IN TITLE <br />BLOCK SAME SHEET <br />REVISION AREA <br />DIMENSIONS <br />(+/-) DIMENSIONS ARE FOR <br />REFERENCE ONLY. CONTRACTOR <br />SHALL FIELD VERIFY AND NOTIFY <br />ARCHITECT/ENGINEER OF ANY <br />+/- X X DISCREPANCIES <br />+/- X' - X" X' - X" SET DIMENSIONS <br />(NON +/- DIMENSIONS) <br />ROOM 1 SPACE NAME <br />ROOM NAME ROOM NAME <br />101 ROOM NUMBER <br />150 SF ~ ROOM AREA <br />NORTH ARROW <br />INDICATES DIRECTION <br />OF TRUE NORTH <br />N INDICATES DIRECTION <br />OF PROJECT NORTH <br />LEVEL <br />LEVEL NAME <br />0'-0" <br />MATCH LINE <br />BREAK LINE <br />MATCHLINE <br />RE:X00-00 <br />PLAN ELEVATION MARKER <br />iHEIGHT ABOVE I BELOW <br />ESTABLISHED 0.0 ELEVATION <br />EQUIPMENT TAG <br />TAG ID <br />DEMOLITION EXTENT <br />CONNECT TO EXISTING <br />�# OPTIONAL NUMBER DESIGNATION <br />DEMOLITION LINEWORK <br />SHEET NOTE (DEMO AND NEW WORK) OBJECT TO BE REMOVED <br />SEE NOTE LEGEND ON SAME SHEET. <br />CONSULTING ARCHITECT/ENGINEER <br />I CLARK, RICHARDSON AND BISKUP <br />CONSULTING ENGINEERS, INC. <br />CRB ARCHITECTS -ENGINEERS P.C. <br />1 GLENLAKE PARKWAY <br />SUITE 600 <br />\ ATLANTA, GA 30328 <br />PHONE: 404-860-1440 <br />FAX: 404-860-1442 <br />PROJECT TITLE <br />ZEPHYRHILLS LINE 12 <br />REV <br />BY <br />DATE <br />DESCRIPTION <br />0 <br />GJH <br />25AUG21 <br />ISSUED FOR BID <br />1 <br />GJH <br />22SEP21 <br />ISSUED FOR PERMIT <br />LICENSEE _ 1 1 ' (jig, <br />Gordon James Handziuk, PE <br />State of Florida <br />Professional Engineer <br />License No. 91122 <br />This item has been digitally signed and <br />sealed by Gordon James Handziuk, PE <br />on the date adjacent to the seal. <br />Printed copies of this document are not <br />considered signed and sealed and the <br />signature must be verified on any <br />electronic copies. <br />129 Sep 2021 <br />CRB ARCHITECTS -ENGINEERS P.C. LICENSE #09000002537 <br />CRB CONSULTING ENGINEERS, INC LICENSE #F96000003389 <br />INFORMATION CONTAINED HEREIN IS CONSIDERED CONFIDENTIAL. THIS <br />DOCUMENT IS NOT TO BE USED, REPRODUCED, OR DISCLOSED IN WHOLE OR <br />PART WITHOUT THE PRIOR WRITTEN PERMISSION OF BLUETRITON BRANDS. <br />PROJ. NO. <br />217043.00 <br />DESIGNED BY: <br />SB <br />SCALE: <br />NOT TO SCALE <br />CHECKED BY: <br />GJH <br />SHEET SIZE: <br />30x42 <br />APPROVED BY: <br />GJH <br />DRAWING TITLE <br />PLUMBING <br />LEAD SHEET <br />�DRAWNG NUMBER <br />POO-01 <br />