Laserfiche WebLink
ROOF FINISH <br />PER ELEVATION <br />12 <br />15 ROOF SHEATHING <br />MANUFACTURED <br />ROOF TRUSS <br />MTL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />DETAIL <br />61SOFFIT <br />3/411 11-001 <br />ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOFTRUSS <br />MTL DRIP EDGE <br />�'—ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />SOFFIT DETAIL <br />7 13/4 <br />04 <br />C14 <br />L V-4" L <br />k�-2" 11-8.1 2" �) <br />. <br />FALSE FOAM LOUVER DETAIL TYP <br />8 <br />177- <br />" 6" <br />4" 4" <br />C14 <br />C) C) <br />00 00 <br />EPS <br />N FOAM <br />DETAIL <br />9 <br />JBRACKET <br />ill 11-011 <br />PROVIDE FILLED SOLID <br />CMU ABOVE LINTEL TO <br />TIE BEAM <br />FLASHING <br />CASING BEAD WITH WEEP HOLES <br />2X8 LEDGER ATTACHED TO <br />,,----PT <br />WALL W/ 3/8" X 5" TITEN HD AT <br />12" O.C. STAGGERED <br />(S)H10A-2 <br />ROOF FINISH PER ELEVATION <br />UNDERLAYMENT <br />ELEV AT V-0" <br />- T2_ T.O.M. <br />__15 ROOF SHEATHING <br />(S)A23 <br />MTL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINUM WRAP <br />2'-0" <br />(S)A23 —ALUMINUM SOFFIT <br />PT 2X4 LEDGER AT7ACHED TO <br />WALL W/ 3/16" TAPCONS W/ <br />MIN 2-1/2" EMBEDMENT 6" O.C. <br />BTM AT T-6" <br />SOFFIT DETAIL <br />10 <br />3/411 <br />T71 <br />PT 2X8 LEDGER ATTACHED TO WALL <br />W/ 3/8" X 5" TITEN HD AT 12" O.C. <br />STAGGERED <br />C14 <br />0 <br />o <br />4P <br />LEDGER DETAIL <br />3/411 = 1 <br />1-011 <br />----------------- <br />7/8" S CCO WITH WEEP <br />4" STUCCO OVER ME SCREED OVER <br />BAND FLASHING <br />8 <br />A5 <br />WEEP <br />SCREED 51 12 <br />F- -1 <br />C) W <br />-1 = <br />04 <br />z <br />21,-( <br />4" STUCCO <br />BAND <br />5/8" <br />STUCCO <br />OVER <br />MASONRY- <br />0 a&-;; z - 6M h�16 I n._ <br />INININININ11 - <br />INININININININI <br />INININININININI <br />liMIMIMINIMIMIM! <br />. <br />FRONT ELEVATION B <br />1/411 = 1 1-011 <br />a 0 i"a I'm A i'm I'm A i'w I'm A ro <br />-10 NO ro 72 ro �w 7N <br />A ro 7& <br />A ro -In ro ra <br />-10 im i-W <br />ME ON i-W -In ON AMN. ro ANNE in <br />Avffl <br />�_7/8" <br />STUCCO <br />OVER FRAM% <br />102ND <br />FOLOORFF <br />CONTROL JOINT <br />ELEV AT 81-81, Ali__� <br />T.O.M. k-r <br />MID WALL <br />WEEP SCREED <br />STUCCO <br />,,�-5/8" <br />OVER <br />MASONRY <br />ELEV AT U-10" <br />SHINGLE <br />ROOF <br />I im <br />100011 <br />12 <br />16-8" <br />�-7/8" STUCCO <br />ELEV AT 18'-0" Adk <br />T. 0. P. <br />V-011 <br />,—CASING BEAD WITH <br />WEEP SCREED OVER <br />FLASHING <br />ELEV AT 1 U-0" <br />2ND FLOOR FF <br />ELEV AT 8'-8" <br />T.O.M. <br />-",—WEEP SCREED <br />j I ELEV AT U-0" Ai__� <br />In 1 1 ST FLOOR FF \?F <br />ELEV AT 18'-0" <br />T.O.P. <br />ELEV AT 10'-0" <br />OVER FRAME_� / 2ND FLOOR FF 11--r <br />CONTROL JOINT NTROL JOINT <br />r ELEV AT 8'-8" <br />�_5/8" STUCCO T.O.M. <br />OVER —MID WALL �D 2'-0" C UNIT <br />MASONRY WEEP SCREED <br />Amllllnllj� AND PAD <br />NJELEV AT <br />RIGHT ELEVATION B 1�\—GRADE LINE <br />1/811 = 1 1-011 <br />ELEV AT 18'-0" <br />T.O.P. <br />ELEV AT 1 U-10" <br />2ND FLOOR FF <br />11ju ILI <br />ELEV AT 8'- <br />T.O. <br />A/C UNIT 2,_ %/8" STUCCO <br />AND PAD -0" OVER LMID WALL <br />MASONR% WEEP SCREED <br />ELEV AT 0!-0" <br />GRADE LINE 1 ST FLOOR FF <br />LEFT ELEVATION B <br />1/891 = 1 1-011 <br />12 <br />5F!—j <br />F- F_ <br />12'-0" <br />9 W <br />13'-4" A- 12'-0" <br />ce) �-7/8" STUCCO <br />-1 OVER FRAM% <br />CONTROL JOINT <br />V-R/\ JUN I <br />VIRTUAL REV�EW ASSIST <br />Virtual Review Assist, Inc. <br />Plans Review completed and ap)Vped <br />3C <br />for Compliance with the 2020 FB h <br />Edition by Debra Anne Klahr PX2300 <br />SLOPE <br />5:12 <br />W <br />a- <br />0 <br />UJE; <br />W <br />0- <br />0 <br />-1 <br />ctiE <br />7'-4" 1. 6-11 " <br />101-01, R <br />VENT <br />---------- <br />SLOPE <br />5:12 7 <br />7'-0" RIDGE <br />VENT <br />SLOPE <br />5:12 <br />W <br />a_ SLOPE SLOPE <br />0 <br />77 5:12 5:12 <br />Lo <br />6-0" RIDGE <br />VENT <br />_j <br />SLOPE SLOPE > <br />5:12 5:12 <br />L ZD r—T _j_ <br />It& 1 1-06f W <br />ROOF PLAN B <br />1/819 = 1 1-091 <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS'NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC'OF 0.25 OR LESS. (IJITILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE/ UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C 1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />ROOF GENERAL NOTES: <br />* G.C. VERIFY ROOF PITCH <br />ROOF PITCH VARIES PER SUBDIVISIONS (5/12 PR 5.9/12) <br />IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF <br />SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. <br />ROOF CRITERIA <br />- 12" OVERHANG U.N.O. <br />- PLUMB CUT FASCIA <br />- ROOF PITCH PER ELEVATION <br />- WINDLOAD CALC. PER ASCE 7-98 (VARIES BY LOCATION) <br />- SHINGLE LOADING <br />ROOF VENT CALCULATIONS: <br />NOTE: VERIFY NTH GENERAL CONTRACTOR ALL ROOF VENT <br />LOCATIONS, QUANTITIES, AND SIZES. ROOF VENTS SHALL BE <br />INSTALLED FOR A MIN. OF VENTED AREA AS LISTED BELOW OR <br />EQUIVALENT SYSTEM PER 7TH EDITION (2020) FBC, SECTION R806 <br />FORMULA = S.F. / 300 (1/300) - 144 (TO CONVERT TO SQ. INCHES) <br />NET SQ. INCH REQUIREMENT <br />ATTIC AREA 1 = 1268 SQ FT <br />VENTILATION REQUIRED = 609 SQ IN <br />VENTILATION PROVIDED AT RIDGE = 306 SQ IN <br />VENTILATION PROVIDED AT SOFFIT = 1197 SQ IN <br />AT -TIC AREA 2 = 445 SQ FT <br />VENTILATION REQUIRED = 214 SQ IN <br />VENTILATION PROVIDED AT RIDGE = 108 SQ IN <br />VENTILATION PROVIDED AT SOFFIT = 425 SQ IN <br />ATTIC VENTILATION <br />ATTIC VENTILATION TO BE IN COMPLIANCE WITH THE FLORIDA <br />BUILDING CODE 7TH EDITION (2020) RESIDENTIAL R806. <br />THE MINIMUM NET FREE VENTILATING AREA SHALL BE 11150 OF THE <br />AREA OF THE VENTED SPACE. THE VENTILATED AREA MAY BE <br />REDUCED TO 1/300 PROVIDED THAT AT LEAST 40% BUT NO MORE <br />THAN 50% OF THE REQUIRED VENTILATION IS PROVIDED IN THE <br />UPPER PORTION OF THE SPACE TO BE VENTILATED. UPPER <br />VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET (MEASURE <br />VERTICALLY) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, <br />WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY <br />EAVE OR CORNICE VENTS. <br />CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN. <br />V AL ES To BE VERIFIED WITH MANUFACTURER SPECIFICATIONS) <br />RIDGE VENTS - 18 SQ. IN. OF NET FREE AREA I LINEAR FT. <br />• OFF -RIDGE VENTS - 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS - 7 SQ. IN. OF THE NET FREE AREA / SQ. FT. <br />IF NOT ENOUGH VENTED SOFFIT IS PROVIDED DUE TO FIRE <br />PROTECTION, THE CONTRACTOR SHALL USE DECK -AIR OF OTHER <br />APPROVED MATERIAL TO PROVIDE SUFFICIENT IN -TAKE VENTILATION <br />LOMANCO DECK -AIR - 9 SQ. IN. OF NET FREE AREA / FT. FOR SHINGLE <br />36 SQ. IN. OF NET FREE AREA / FT. FOR TILE <br />NOTE: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR SIDE -HINGE <br />DOORS SHALL BE TESTED AND LABELED WITH A PERMANENT LABEL <br />PROVIDING TRACE ABILITY TO MANUFACTURER AND PRODUCT <br />C*4 <br />C14 <br />C) <br />in <br />C) <br />Go <br />L0 <br />z <br />W <br />0 <br />W <br />z <br />LO E <br />> Q o <br />a) <br />, 0 <br />cy) <br />C Y) <br />a U <br />U -0-0 2 <br />C: <br />E -E- 80 <br />::) 0 C) <br />6 LL- ca, R < <br />U < <br />a) <br />6 <br />U LL] a <br />cO E <br />�C-1 �C_OL A <br />WIA <br />13f (9 W <br />Ld Cd W 0 <br />LIJ P W _j wm�_o <br />W�-< Wm_i wg�ezx z <br />X:03 2 _j < 0 W < LL C-) 0 0, _j 0 <br />< - W 12 " <br />< <br />0 M 0 F- <br />D 0 >1 � Z W z 6 <br />0130 OLLOROOMOZ <br />W W <br />Cy 0 0 <br />0 Z <br />00a_�0wzwW0Ww<01_ <br />_j <br />_j<,�0zW�QzzWz0W00(1L <br />Cl) <br />LL <br />< 2 �_ < <br />0 W I— 2 W 6 0 <br />< <br />0 it Ej Z) i5 Z <br />LL < 0 < LL <br />C:) <br />0 <br />z CN <br />W <br />LD <br />0 <br />F-: (y) <br />< u) CY) <br />Lq <br />_j <br />U) <br />LL V <br />U) I r.., <br />z <br />< W < Lf) <br />F- W cL cyi <br />< < <br />Z F- <br />z <br />W <br />W <br />_j C:) <br />C:) <br />(0 <br />04 <br />C14 <br />C) <br />C%4 <br />FIL <br />C14 <br />C:) <br />C) <br />06 <br />(D <br />06 <br />C:) <br />CN <br />c) <br />cN <br />a <br />N <br />04 <br />CN <br />C) <br />CN <br />C:) <br />Cq <br />C:) <br />CNI <br />c) <br />N <br />C) <br />" <br />C� <br />CN <br />CD <br />" <br />d) <br />C� <br />Ob <br />9 <br />Lh <br />— <br />Ob <br />9 <br />A <br />-r-- <br />11 <br />04 <br />6 <br />Cn <br />CN <br />q- <br />C) <br />,- <br />C) <br />j) <br />C) <br />CS <br />6 <br />"L, <br />C) <br />C6 <br />C) <br />0 <br />U-) <br />a) <br />> <br />C:) <br />C:1 <br />C-� <br />CD <br />C6 <br />C� <br />-r <br />C:) <br />L0 <br />C) <br />(0 <br />C�., <br />r-- <br />w <br />Z <br />Z2 <br />C) <br />4_0 <br />W <br />III W <br />w <br />F- 5; <br />0 <br />F- <br />_j Lj <br />0 � < <br />0 <br />Lr) <br />-0 <br />z <br />W <br />W <br />< <br />F-- <br />I._ <br />W Z) <br />0 <br />M -2 <br />i­- X: z <br />r*4 <br />(D <br />ZO !3=: w <br />00 <br />0� <br />>- <br />>- fl� 2 <br /><W0 <br />n z w <br />M <br />Z z Lj- <br />W <br />W <br />< �_ <br />�z <br />C) <br />a- W <br />W <br />L/)zz <br />z <br />M<O <br />Se <br />z <br />0 <br />:5 <br />0 <br />0 <br />co <br />z <br />A5 <br />z <br />z <br />W <br />_j <br />C14 <br />IN <br />W <br />0 <br />LAST PLOT DATE <br />> <br />Apr. 13, 22 <br />Z <br />'0 <br />EXTERIOR <br />ELEVATIONS B & <br />_j <br />ROOF PLAN <br />