ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /4„ = 1'-0" <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4" = 1'-0„ <br />1 IAIC rlC M^^C <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 2/0 or 410 SER Alu <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />�— 4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />JUN 1 1 20*U <br />V---1 - <br />VIRTUAL REVIEW ASSIST <br />Virtual Review Assist, Inc. roved <br />Flans RF`v*ew cornPleted an P <br />for ccrnpliar:c� \Mth the 2020 PX2300 <br />Edition by Debra Anne K <br />lahr <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH- <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />S <br />SMOKE DETECTOR <br />V-0" <br />01 MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />E)= 110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />6 SWITCH AT 36" <br />U 3 WAY SWITCH AT 36" <br />-vi;-t 4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />--0 PUSH-BUTTON DOORBELL <br />A3 CLG MNT LT FIXTURE <br />}B CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />CANS MAY BE <br />50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />0 50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />SMOKE DETECTOR <br />°U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />-U-24- UNDER CABINET 24" <br />-S-24- SINGLE 24" FLUOR STRIP <br />-D-24- DOUBLE 24" FLUOR STRIP <br />U-36 UNDER CABINET 36" <br />S-36 - SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />E-& 24 � 24" VANITY LIGHTING <br />36 :u� 36" VANITY LIGHTING <br />4848" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />EXHAUST FAN <br />�p DOUBLE FLOOD LIGHT W/ COVERS AND <br />U 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />[4A CEILING RETURN AIR <br />® A/C REGISTER <br />([ THERMOSTAT <br />® SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />i <br />� s <br />F 10 < k <br />'. <br />46 <br />(n E <br />Cf) CN lu <br />to 7 <br />Ln V � � a <br />E L t Q <br />2 O 2 <br />O <br />U-o o Q <br />-s U <br />.N V w Q� <br />W L OO E rn <br />�a ^�a-0 <br />Uj N Cw7 <br />L L Q <br />�Ld Uj W0H <br />W HQWOM M�� W zW Z <br />o O J O <br />low LL O <br />O R <br />~ <br />0 <br />— <br />QJ 2 m Q <br />? <br />OWWWOZOwOOmZz¢U <br />('1 <br />� <br />O <br />Z <br />� O a> z Y O Z z LL 0 W O a <br />¢�WOg�~—�Wo��0IL <br />Ow o oQz <br />LL O LL. <br />O <br />O <br />Z N <br />0� <br />U J ti <br />0 CM O <br />Q u) M � <br />W r*­ <br />lq <br />W0-of) <br />Q >- Q QO <br />ZV1.-- <br />z 3: <br />LUW <br />_jQ <br />co <br />N <br />N <br />O <br />N <br />I <br />ti <br />N <br />1 <br />O <br />O <br />00 <br />(O <br />00 <br />O <br />(V <br />O <br />N <br />O <br />(V <br />N <br />r <br />N <br />N <br />CD <br />N: <br />CD <br />N <br />N <br />O <br />N <br />O <br />N <br />C)O <br />N <br />N <br />00 <br />Lo <br />00 <br />O <br />M <br />r- <br />" <br />N <br />O <br />M <br />N <br />C:)O <br />O <br />C)r <br />O <br />O <br />P <br />0 <br />(O <br />0 <br />' <br />O <br />N <br />^ <br />U) <br />; <br />0 <br />0 <br />N <br />0 <br />M <br />0 <br />0 <br />In <br />0 <br />(O 1 <br />0 <br />I` <br />CO <br />V) <br />z z <br />z 0 <br />C) <br />_ <br />W��' <br />wW(A <br />O <br />U0 <br />! <br />0�w� <br />Q <br />ZW~� <br />Q <br />�m0z <br />v <br />Z J <br />,CMMV <br />3 <br />W <br />�Q�o <br />W <br />M <br />azzLL <br />< 0 <br />Cy <br />w 'CV <br />O-<z <br />�- <br />Q <br />UWzz <br />z <br />y<0 <br />.. <br />Z <br />U <br />U <br />: <br />O <br />O <br />I <br />W <br />1< <br />z <br />z <br />z <br />W <br />J <br />WC-4 <br />O <br />(V <br />LAST PLOT DATE <br />O <br />Apr. 13, 22 <br />Z <br />0 <br />1ST & 2ND FLOOR <br />� <br />J <br />ELECTRICAL PLAN <br />B <br />