ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />t to lights & outlets <br />? to appliances and GFI <br />)to WH <br />to Range <br />to HVAC <br />MAIN .� <br />150=2/tl <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp tr <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />��J// CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. Al trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />( <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUSTFAN <br />rO. <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />I ] <br />ELECTRIC METER <br />owl <br />PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT, CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />SMOKE DETECTORS <br />SMOKE DETECTORS SHALL BE IN ALL SLEEPING <br />AREAS, SHALL BE INTERCONNECTED, SHALL BE WITHIN <br />1' TO 3' OF PEAK, AND SHALL BE 3' FROM THE <br />SUPPLY OR AIR STREAM, AND EQUIPPED WITH <br />BATTERY BACK-UP. ALL SMOKE DETECTORS TO BE <br />ARC -FAULT PROTECTED. <br />FAIR HOUSING ACT REQUIREMENTS: <br />OPERABLE PARTS OF THE CONTROLS FOR LIGHT SWITCHES, ELECTRICAL <br />OUTLETS, THERMOSTATS AND OTHER ENVIROMENTAL CONTROLS MUST BE <br />LOCATED NO HIGHER THAN 48", AND NO LOWER THAN 15", ABOVE THE FLOOR. <br />IF THE REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE, AN OVERHANGING <br />SHELF) BETWEEN 20 AND 25 INCHES IN DEPTH, THE MAXIMUM HEIGHT IS <br />REDUCED TO 44" FOR FORWARD APPROACH; OR 46" FOR SIDE APPROACH <br />PROVIDED THE OBSTRUCTION (FOR EAXMPLE, A KITCHEN BASE CABINET) IS <br />NOT MORE THAN 24 " IN DEPTH. OBSTRUCTIONS SHOULD NOT EXTEND MORE <br />THAN 25" FROM THE WALL BENEATH A CONTROL. <br />VERIFY P/ <br />LOCATIOI' <br />BUILDER <br />COMP. <br />Wp .. <br />DISC. <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />UNIT'150,0 — ELECTRICAL PLAN <br />SCALE: 1 /4"=V-0" <br />0 <br />u, <br />Ir <br />cc Cj en <br />„CtmX <br />Sao <br />7• ce • C0 �. <br />CV <br />0 <br />N <br />v <br />r�- <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />N <br />W <br />Q <br />�E <br />0 <br />C <br />V <br />0 <br />CD o <br />cc <br />N N <br />A r r a E <br />Q <br />NM V u. <br />J L <br />JELL , W <br />uj <br />o <br />EL <br />o @nm <br />°' °'. m <br />W <br />T. <br />U <br />L0 N Z ¢ J <br />Z <br />N OU <br />U Go <br />W <br />❑D <br />co411111111111. <br />[h <br />Z Nco <br />co <br />z <br />z o <br />J <br />ti <br />U)U,) <br />z a <br />`o <br />Q) <br />LU <br />U <br />Q) <br />O <br />W o <br />IV)Emil <br />U <br />w <br />E <br />of <br />v o <br />rn <br />401 <br />c <br />N <br />.4 <br />o <br />M <br />M <br />¢ <br />o <br />Z <br />u <br />� <br />�o <br />o�Qo <br />>� <br />a <br />�o <br />E00 <br />z® <br />O E <br />N <br />L <br /><a <br />a p <br />w o <br />¢ <br />oK <br />a z <br />w <br />Wm <br />M <br />O <br />zU <br />O� <br />Z <br />_ <br />N <br />0 <br />� <br />W <br />. <br />on <br />N <br />o� <br />ZZ <br />aZ <br />�w <br />�r <br />�F <br />J <br />o <br />w <br />>° <br />a <br />v <br />zQ <br />° <br />�N <br />0 <br />>LO <br />c <br />0 <br />LO <br />Cn <br />co <br />M <br />Q <br />r <br />00 <br />(� m <br />J <br />O <br />Q <br />f-- <br />-0 <br />c- 04 <br />co <br />cy) <br />Q N <br />LO <br />CD} <br />E <br />c V <br />N <br />N <br />Z <br />z <br />E <br />E <br />ca <br />co <br />a <br />U <br />Q p <br />JOB <br />NO: 22-08393-08388 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />