My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (116)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (116)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:54:38 PM
Creation date
2/19/2025 11:44:30 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Sealander Contr
Building Plans - Permit #
10705
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLORIDA HOSPITAL Z PHYRHI S <br />PHARMACY 797 RENOVATION <br />Florida Hospital ephyrhills <br />7050 Gall Boulevard <br />Zephyrhills, IF 33541 <br />Client <br />AHCA <br />Code/ ]File Number. 23/100046 -Project ID Submission Number 106-00-1 <br />Stage IIi <br />PROJECT TEAM DIRECTORY <br />OWNER <br />Florida Hospital Zephyrhills <br />7050 Gall Boulevard <br />Zephyrhills, Florida 33541 <br />Phone: (813) 788-0411 <br />ARCHITECT <br />Burt Hill /Pollock Krieg Architects, Inc. <br />13099 South Cleveland Avenue, Suite 500 <br />Fort Myers, Florida 33907 <br />Phone: (239) 482-4761 <br />Fax: (239) 482-0265 <br />MEP ENGINEER <br />Heery International, Inc <br />4700 Millenia Blvd. <br />Suite 550 <br />Orlando, FL 32839 <br />Phone: (407) 992-6300 <br />Fax: (407) 992- 6399 <br />Industry standards (I.e. ASTM, ANSI, etc.) SHALL HAVE THE SAME FORCE AND EFFECT <br />on performance of work as If copies were directly inserted into the Contract Documents or bound and <br />published therewith. Comply with standards in effect as of the date of the Contract Documents, <br />unless otherwise note or required by authorities having jurisdiction. <br />CODES - All work shall conform to the following codes and ordinances: <br />2007 Florida Building Code, with the first and second 2009 amendments <br />2007 Florida Existing Building Code, with 2009 amendments <br />2007 Florida Plumbing Code, with 2009 amendments <br />2007 Florida Fuel Gas Code, with 2009 amendments <br />2007 Florida Mechanical Code, with 2009 amendments <br />2007 Florida Fire Prevention Code <br />-2006 NFPA 101 Life Safety Plan - Chapter 18119 <br />-2006 AIA Guidelines for Design and Construction <br />- Local Codes and Ordinances where applicable and flood damage prevention ordinances <br />SYMBOLS AND MATERIALS <br />NOTE: The symbols here are specific to the Architectural Drawings as a whole. <br />The Life Safety, Reflected Ceiling Plan and Roof Plan respectively include supplementary legends <br />and drawing notes specific to those sheets. Refer to other disciplines for additional symbols. <br />O <br />WINDOW TYPE <br />--; <br />EARTH <br />ELEVATION BENCHMARK <br />GRANULAR FILL <br />METAL <br />REVISION AND NUMBER <br />FINISH WOOD <br />C.J.D <br />CONTROL JOINT <br />STUCCO OR GYPSUM BOARD <br />124 <br />CONCRETE OR GRAVEL <br />DOOR AND FRAME <br />WITH DOOR NUMBER <br />CONCRETE MASONRY UNIT (CMU) <br />EXISTING DOOR <br />® <br />PLYWOOD <br />METAL STUD WALL <br />ACOUSTIC CEILING TILE <br />MASONRY WALL <br />BATT OR SEMI -RIGID INSULATION <br />EVALUATION <br />208 <br />ROOM NAME AND NUMBER <br />- <br />RIGID INSULATION <br />a— <br />WALL TYPE <br />ROUGH WOOD FRAMING OR BLOCKING <br />LJ' <br />"L <br />2x2 LAY -IN FLUORESCENT FIXTURE <br />BUILDING SECTION <br />2x4 -IN FLUORESCENT FIXTURE <br />—� <br />LAY <br />SECTION OR DETAIL <br />° <br />FLUORESCENT UTILITY FIXTURE <br />0 <br />RECESSED DOWNLIGHT <br />ELEVATION <br />R, <br />SUPPLY AIR DIFFUSER <br /><8>INTERIOR <br />V <br />RETURN AIR REGISTER <br />ELEVATION <br />NORTH <br />FINISH CEILING ELEVATION <br />(All elevations are A.F.F.) <br />® <br />EXIT LIGHT <br />NORTH ARROW <br />2x2 ACOUSTICAL CEILING TILE <br />2x4 ACOUSTICAL CEILING TILE <br />GYPSUM BOARD <br />® <br />MAGNETIC DOOR HOLDER <br />VICINITY MAP <br />, <br />: <br />Fna^saw bfaegkitc Rea r <br />A. <br />Paam"ewt eIONia fta <br />B t, . <br />F �a <br />N <br />iild i.i t' Yal e3ol�e:: Rd <br />Norki, Ave '. <br />r,. C ,I <br />Lr <br />Zr� <br />Iyih+Ils <br />e <br />- L—d <br />_•I .. �ak� <br />�4 <br />e .. <br />` <br />4 <br />Project <br />EV <br />INDEX OF DRAWINGS <br />A0.0 Cover Sheet <br />ARCHITECTURAL <br />A1,0 Life Safety Plan - First Floor <br />A l . l ICRA Plan <br />A2.0 Demolition Plan and Floor Plan <br />A2.1 Reflected Ceiling Plan and Elevations and Schedules <br />A2.2 Roof Plan and Details <br />FIRE PROTECTION <br />F2.1 Fire Protection Plan <br />MECHANICAL <br />MO.1 HVAC Legend and General Notes <br />M2.1 HVAC Level 2 Demolition and New Work Plans <br />M2.2 HVAC Roof New Work Plans <br />M4.0 HVAC Details and Schedules <br />M4.1 HVAC Controls <br />PLUMBING <br />P2.1 Plumbing Plans Demolition and New <br />ELECTRICAL <br />E2.0 Electrical Power - Level 2 Demolition and New Work <br />E2.1 Electrical Lighting- Level 2 Demolition adn New Work Plans <br />E3.0 Electrical Power - Level 3 New Work <br />E4.0 Electrical Riser Details <br />. . ..... ..... , <br />1 L ,:, Cr K SHALL CO IPLY V ITHA.LL <br />1 nEVMLING CODES, FLORIDA I UILDIN'i <br />CODE. NATIOiiNAL ELECTRIC CODE XV-! <br />C IT�r OF ZEPHYRHILLS ORDINANCES <br />REVIEW DATE �� 8'- (O <br />CITY OF ZEPHYRHILLS <br />PLANS EXAMINER <br />, V2 <br />Project No. 10003.00 <br />A0.0 <br />0 2009 BH,P6 Architects, Inc. <br />Y!6/2010 11!0649 AM ` d\,40 0 Cover Sheet.d.on <br />
The URL can be used to link to this page
Your browser does not support the video tag.